Experiments and Modeling in Bubbly Flows at Elevated Pressures

2003 ◽  
Vol 125 (3) ◽  
pp. 469-478 ◽  
Author(s):  
Ranganathan Kumar ◽  
Thomas A. Trabold ◽  
Charles C. Maneri

Measurements of local void fraction, rise velocity, and bubble diameter have been obtained for cocurrent, wall-heated, upward bubbly flows in a pressurized refrigerant. The instrumentation used are the gamma densitometer and the hot-film anemometer. Departure bubble size is correlated in terms of liquid subcooling and bulk bubble size in terms of void fraction. Flow visualization techniques have also been used to understand the two-phase flow structure and the behavior of the bubbly flow for different bubble shapes and sizes, and to obtain the bubble diameter and rise velocity. The lift model is provided explicitly in terms of Eotvos number which is changed by changing the system pressure. In general, Eotvos number plays a strong role in determining both bubbly lift and drag. Such insight coupled with quantitative local and averaged data on void fraction and bubble size at different pressures has aided in developing bubbly flow models applicable to heated two-phase flows at high pressure.

Author(s):  
R. Kumar ◽  
T. A. Trabold ◽  
C. C. Maneri

Measurements of local void fraction, rise velocity and bubble diameter have been obtained for cocurrent, wall-heated, upward bubbly flows in a pressurized refrigerant. The instrumentation used was the gamma densitometer and the hot-film anemometer. Departure bubble size and bulk size measurements were also made and correlated with appropriate parameters. Flow visualization techniques have also been used to understand the two-phase flow structure and the behavior of the bubbly flow for different bubble shapes and sizes, and to obtain the rise velocity. Such insight, coupled with quantitative local and averaged data on void fraction and bubble size at different pressures, has aided in developing bubbly flow models applicable to heated two-phase flows at high pressure.


Author(s):  
T-C Kuo ◽  
A-S Yang ◽  
C-C Chieng

The coupled Eulerian-Lagrangian approach was used to study the effects of bubble size and high-pressure transport behaviour on the phase distribution mechanisms in vertically upward air-water two-phase bubbly flows. The approach solves the conservation equations of liquid phase in Eulerian space and equations of motion in conjunction with the random walk method for dispersed air bubbles in Lagrangian space. Numerical calculations were performed under conditions of three bubble diameters (2.8, 4.0 and 5.0 mm) and two different pressure levels (0.1 and 7.17 MPa) to explore the flow and void fraction development phenomena. Simulation results indicate the tendency of higher slip ratios and the movement of the void fraction peak towards the flow core for larger gas bubbles. In the pressure range 0.1-7.17 MPa, predictions reveal that the effect of high-pressure transport behaviour on the phase distribution is insignificant.


Author(s):  
Mohamed E. Shawkat ◽  
Chan Y. Ching ◽  
Mamdouh Shoukri

An experimental investigation was performed in air-water bubbly flow to study the liquid turbulence spectra in a 200mm diameter vertical pipe. A dual optical probe was used to measure the local void fraction and bubble diameter while the liquid velocities were measured using hot-film anemometry. Experiments were performed at two liquid superficial velocities of 0.2 and 0.68m/s for gas superficial velocities in the range of 0 to 0.18m/s. Generally, as the void fraction increases there is a turbulence augmentation. However, a turbulence suppression was observed near the pipe wall at the higher liquid flow rate for low void fraction. In the augmentation case, the turbulence spectra showed a significant increase in the energy at the wave number range comparable to the bubble diameter. In the suppression case, the spectra showed that suppression initially occurs at the low wave number range and then extends to higher wave numbers as suppression increased.


2010 ◽  
Vol 29-32 ◽  
pp. 143-148
Author(s):  
Min Xiang ◽  
S.C.P. Cheung ◽  
Ji Yuan Tu ◽  
Wei Hua Zhang ◽  
Yang Fei

The aim of the study was to develop a numerical model to reproduce the bubbly flow field created by ventilated cavity which includes three different regions. The model was established based on the Eulerian-Eulerian two-fluid model coupled with a population balance approach which is solved by the Homogeneous Multiple-Size-Group (MUSIG) model to predict bubble size distribution. Base on the model, the simulation was carried out at the experimental condition of Su et al. (1995). Firstly three regions were successfully captured proved by the spatial voidage distribution and streamline shape. Then distributions of void fraction and Sauter mean bubble diameter at various sections below the cavity corresponding to three regions respectively were plotted against experimental data. A close agreement was observed in the void fraction distribution which indicates that qualitative details of the structure of the two-phase flow field below the cavity was successfully produced. The Sauter mean bubble diameter in the pipe flow region was under-predicted for about 10%. In conclusion, the proposed model was validated in predicting the multi-region flow field below the ventilated cavity which will provide a valuable insight in designing and controlling of the two phase systems with the detailed flow field information obtained.


Author(s):  
M.-L. Bordas ◽  
A. Cartellier ◽  
P. Se´chet

Pressure drop and gas void fraction are important parameters for the design of multiphase packed bed reactors which are widely used in petrochemical industry. Several experimental studies have been devoted to the hydrodynamics of two-phase cocurrent upflow or downflow through fixed beds, and various correlations of limited range of validity are available in the literature. However, there is not yet a clear agreement on the form of the momentum equations to be used in such systems. Early attempts devoted to the pressure drop estimate were based on an extension of the Lockhart-Martinelli approach (Sweeney 1967), Rao et al. 1983). More recently, Attou at al. (1999) proposed the first serious attempt to adapt the Eulerian two-fluid model to cocurrent bubbly flows through packed beds. From an analysis of their proposal, it happens that the basic mechanical equilibrium for the gas phase needs to be reconsidered. In this scope, we derived a new model on the basis of the so-called hybrid approach initially developed for bubbly flows in ducts in absence of shear-induced turbulence (Achard and Cartellier 2000). As a first application, we considered a mean unidirectional flow of a bubbly mixture through a porous medium composed of beads uniform in size. For steady and fully established flows, and assuming a flat void fraction (α) profile, the resulting momentum equations for each phase write: Liquidphase:−dpdz=ρLg+fLS−fLG1−α(1)Gasphase:−dpdz=ρGg+fLS+fLGα(2) where fLS is the resultant of the liquid shear stress exerted on beads surface and on exterior walls, and where the quantity fLG = α F* / Vp represents the interaction force density between the gas and the liquid (F* is the mean force on bubbles and Vp = 4πa3/3 denotes the bubble volume, a being the bubble radius). The main difference with the model derived by Attou et al. is the presence of the fLS term in the gas phase equation. Without this term, the relative velocity of bubbles would be controlled by the axial pressure gradient dP/dz even in non accelerating flows which is unphysical. On the opposite, in the present model (1–2) the relative movement of bubbles is simply due to buoyancy. The set of equations (1–2) provides a mean to exploit the experimental data to derive the required closures, namely the evolution of the friction fLS with the gas content and that of the momentum exchange between phases fLG. Notably, from (1) and (2), one gets fLG=α(1−α)(ρL−ρG)g(3) In order to establish reliable closures, available experimental data of the literature are currently revisited under this framework. For the friction term, which is the principal contribution to the pressure drop, the usual closure law for fLS as given by an Ergun equation adapted to two-phase flows is under analysis. For the interfacial momentum transfer, the objective is to evaluate an “apparent” drag coefficient defined as Cd = F*/[ρL Ur2 π a2 / 2] where the mean relative velocity Ur is defined as the difference between the mean gas and liquid velocities averaged over a volume. Indeed, paralleling an approach already exploited for bubbly flows in ducts (Riviere and Cartellier 1999), it happens that the mean void fraction can be derived from equations (1) and (2) assuming a flat void fraction profile: β(1−β)−α(1−α)=(4π/3)α(1−α)[gδ2VSLνc](aδ)2fd(4) where δ is the typical size of the pores and where fd = (π/2) Rep Cd is expected to be a function of the bubble size, the porosity ε and the void fraction. To extract fd or Cd from (4), a characteristic bubble size must be specified. As shown Fig.1, the bubble size is controlled by the bed geometry and evolves between 0.2 δ and 3 δ in the dilute limit (Bordas et al. (2001)). Analysis of the existing data will be presented based on these size estimates, and comparison will be performed of this “apparent” drag with values measured for isolated bubbles in fixed beds (Fig.2).


2020 ◽  
Vol 10 (16) ◽  
pp. 5443
Author(s):  
Jinyeong Bak ◽  
Huiyung Kim ◽  
Jae Jun Jeong ◽  
Dongjin Euh ◽  
Byongjo Yun

In a multidimensional two-phase flow analysis, bubble size significantly affects interfacial transfer terms such as mass, momentum, and energy. With regard to bubbly flow, the application of a simple correlation-type bubble size model presents certain advantages, including short calculation times and ease of usage. In this study, we propose a semi-theoretical correlation developed from a steady state bubble number density transport equation for predicting the distribution of local bubble size using a computational fluid dynamics (CFD) code. The coefficients of the new correlation were determined using the local bubble parameters obtained on the basis of three existing vertical air-water experiments. Finally, these were implemented in commercial CFD code and evaluated against experimental data, which showed that the proposed correlation exhibits good prediction capability for forced convective air-water bubbly flows under low pressure conditions.


Author(s):  
Isao Kataoka ◽  
Kenji Yoshida ◽  
Tsutomu Ikeno ◽  
Tatsuya Sasakawa ◽  
Koichi Kondo

Accurate analyses of turbulence structure and void fraction distribution are quite important in designing and safety evaluation of various industrial equipments using gas-liquid two-phase flow such as nuclear reactor, etc. Using turbulence model of two-phase flow and models of bubble behaviors in bubble flow and slug flow, systematic analyses of distributions of void fraction, averaged velocity and turbulent velocity were carried out and compared with experimental data. In bubbly flow, diffusion of bubble and lift force are dominant in determining void fraction distribution. On the other hand, in slug flow, large scale turbulence eddies which convey bubbles into the center of flow passage are important in determining void fraction distribution. In turbulence model, one equation turbulence model is used with turbulence generation and turbulence dissipation due to bubbles. Mixing length due to bubble is also modeled. Using these bubble behavior models and turbulence models, systematic predictions were carried out for void distributions and turbulence distributions for wide range of flow conditions of two phase flow including bubbly and slug flow. The results of predictions were compared with experimental data in round straight tube with successful agreement. In particular, concave void distributions in bubbly flow and convex distribution in slug flow were well predicted based on the present model.


Author(s):  
Daeseong Jo ◽  
Shripad T. Revankar

A two phase bubbly flow through a packed bed was studied for dominant bubble breakup and coalescence mechanisms through experiments and CFD modeling. Data on various two-phase parameters, such as local void fraction, bubble velocity, size, number, and shape were obtained from the high speed video images. Results indicated that when a flow regime changed from bubbly to either trickling or pulsing flow, the number of average size bubbles significantly decreased and the shape of majority of bubbles was no longer spherical. The bubble coalescence and breakup mechanisms depend on local conditions such as local velocity of the bubble and pore geometry. The CFD analysis using CFX software package was carried out to study bubble size distributions. In the analysis the models for interactions were examined for each case of bubble breakup flow and bubble coalescence. A comparative study was performed on the resulting bubble size distributions, breakup and coalescence rates estimated by individual models. For change of bubble size distributions along the axial direction medians was used as an comparative parameter and the CFD results on bubble medians were compared against the experimental data. This comparative study showed that the predictions estimated by CFD analyses with the bubble breakup and coalescence models currently available in the literature do not agree with the experimental data.


Sign in / Sign up

Export Citation Format

Share Document