Effect of Microcomputed Tomography Voxel Size on the Finite Element Model Accuracy for Human Cancellous Bone

2005 ◽  
Vol 127 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Yener N. Yeni ◽  
Gregory T. Christopherson ◽  
X. Neil Dong ◽  
Do-Gyoon Kim ◽  
David P. Fyhrie

The level of structural detail that can be acquired and incorporated in a finite element (FE) analysis might greatly influence the results of microcomputed tomography (μCT)-based FE simulations, especially when relatively large bones, such as whole vertebrae, are of concern. We evaluated the effect of scanning and reconstruction voxel size on the μCT-based FE analyses of human cancellous tissue samples for fixed- and free-end boundary conditions using different combinations of scan/reconstruction voxel size. We found that the bone volume fraction (BV/TV) did not differ considerably between images scanned at 21 and 50 μm and reconstructed at 21, 50, or 110 μm (−0.5% to 7.8% change from the 21/21 μm case). For the images scanned and reconstructed at 110 μm, however, there was a large increase in BV/TV compared to the 21/21 μm case (58.7%). Fixed-end boundary conditions resulted in 1.8% [coefficient of variation (COV)] to 14.6% (E) difference from the free-end case. Dependence of model output parameters on scanning and reconstruction voxel size was similar between free- and fixed-end simulations. Up to 26%, 30%, 17.8%, and 32.3% difference in modulus (E), and average (VMExp), standard deviation (VMSD) and coefficient of variation (COV) of von Mises stresses, respectively, was observed between the 21/21 μm case and other scan/reconstruction combinations within the same (free or fixed) simulation group. Observed differences were largely attributable to scanning resolution, although reconstruction resolution also contributed significantly at the largest voxel sizes. All 21/21 μm results (taken as the gold standard) could be predicted from the 21/50 radj2=0.91-0.99;p<0.001, 21/110 radj2=0.58-0.99;p<0.02 and 50/50 results radj2=0.61-0.97;p<0.02. While BV/TV, VMSD, and VMExp/σz from the 21/21 could be predicted by those from the 50/110 radj2=0.63-0.93;p<0.02 and 110/110 radj2=0.41-0.77;p<0.05 simulations as well, prediction of E, VMExp, and COV became marginally significant 0.04<p<0.13 at 50/110 and nonsignificant at 110/110 0.21<p<0.70. In conclusion, calculation of cancellous bone modulus, mean trabecular stress, and other parameters are subject to large errors at 110/110 μm voxel size. However, enough microstructural details for studying bone volume fraction, trabecular shear stress scatter, and trabecular shear stress amplification VMExp/σz can be resolved using a 21/110 μm, 50/110 μm, and 110/110 μm voxels for both free- and fixed-end constraints.

2020 ◽  
Vol 143 (2) ◽  
Author(s):  
Matthew B. L. Bennison ◽  
A. Keith Pilkey ◽  
W. Brent Lievers

Abstract Cancellous bone is an anisotropic structure with architectural and mechanical properties that vary due to both skeletal site and disease state. This anisotropy means that, in order to accurately and consistently measure the mechanical properties of cancellous bone, experiments should be performed along the primary mechanical axis (PMA), that is, the orientation in which the mechanical properties are at their maximum value. Unfortunately, some degree of misalignment will always be present, and the magnitude of the resulting error is expected to be architecture dependent. The goal of this work is to quantify the dependence of the misalignment error, expressed in terms of change in apparent elastic modulus (ΔE), on both the bone volume fraction (BV/TV) and the degree of anisotropy (DA). Finite element method (FEM) models of bovine cancellous bone from five different skeletal sites were created at 5 deg and 20 deg from the PMA determined for each region. An additional set of models was created using image dilation/erosion steps in order to control for BV/TV and better isolate the effect of DA. Misalignment error was found to increase with increasing DA and decreasing BV/TV. At 5 deg misaligned from the PMA, error is relatively low (&lt;5%) in all cases but increases to 8–24% error at 20 deg. These results suggest that great care is needed to avoid introducing misalignment error into experimental studies, particularly when studying regions with high anisotropy and/or low bone volume fraction, such as vertebral or osteoporotic bone.


2015 ◽  
Vol 137 (1) ◽  
Author(s):  
Arnav Sanyal ◽  
Joanna Scheffelin ◽  
Tony M. Keaveny

Prior multiaxial strength studies on trabecular bone have either not addressed large variations in bone volume fraction and microarchitecture, or have not addressed the full range of multiaxial stress states. Addressing these limitations, we utilized micro-computed tomography (μCT) based nonlinear finite element analysis to investigate the complete 3D multiaxial failure behavior of ten specimens (5 mm cube) of human trabecular bone, taken from three anatomic sites and spanning a wide range of bone volume fraction (0.09–0.36), mechanical anisotropy (range of E3/E1 = 3.0–12.0), and microarchitecture. We found that most of the observed variation in multiaxial strength behavior could be accounted for by normalizing the multiaxial strength by specimen-specific values of uniaxial strength (tension, compression in the longitudinal and transverse directions). Scatter between specimens was reduced further when the normalized multiaxial strength was described in strain space. The resulting multiaxial failure envelope in this normalized-strain space had a rectangular boxlike shape for normal–normal loading and either a rhomboidal boxlike shape or a triangular shape for normal-shear loading, depending on the loading direction. The finite element data were well described by a single quartic yield criterion in the 6D normalized-strain space combined with a piecewise linear yield criterion in two planes for normal-shear loading (mean error ± SD: 4.6 ± 0.8% for the finite element data versus the criterion). This multiaxial yield criterion in normalized-strain space can be used to describe the complete 3D multiaxial failure behavior of human trabecular bone across a wide range of bone volume fraction, mechanical anisotropy, and microarchitecture.


2011 ◽  
Vol 278 (1721) ◽  
pp. 3067-3073 ◽  
Author(s):  
Michael Doube ◽  
Michał M. Kłosowski ◽  
Alexis M. Wiktorowicz-Conroy ◽  
John R. Hutchinson ◽  
Sandra J. Shefelbine

Many bones are supported internally by a latticework of trabeculae. Scaling of whole bone length and diameter has been extensively investigated, but scaling of the trabecular network is not well characterized. We analysed trabecular geometry in the femora of 90 terrestrial mammalian and avian species with body masses ranging from 3 g to 3400 kg. We found that bone volume fraction does not scale substantially with animal size, while trabeculae in larger animals' femora are thicker, further apart and fewer per unit volume than in smaller animals. Finite element modelling indicates that trabecular scaling does not alter the bulk stiffness of trabecular bone, but does alter strain within trabeculae under equal applied loads. Allometry of bone's trabecular tissue may contribute to the skeleton's ability to withstand load, without incurring the physiological or mechanical costs of increasing bone mass.


Author(s):  
William Zaylor ◽  
Betty Sindelar ◽  
John R. Cotton

Currently about 10 million Americans report signs and symptoms of TMJ dysfunction. One form of treatment for TMJ dysfunction is dental splints which reorient the jaw during mastication. This presumably changes the direction, magnitude and location of mechanical loads on the mandibular condyle of the temporomandibular joint (TMJ). The precise nature of load changes and their effect on the underlying condylar trabecular bone have not been reported.


2016 ◽  
Vol 13 (114) ◽  
pp. 20150991 ◽  
Author(s):  
Patrik Christen ◽  
Friederike A. Schulte ◽  
Alexander Zwahlen ◽  
Bert van Rietbergen ◽  
Stephanie Boutroy ◽  
...  

A bone loading estimation algorithm was previously developed that provides in vivo loading conditions required for in vivo bone remodelling simulations. The algorithm derives a bone's loading history from its microstructure as assessed by high-resolution (HR) computed tomography (CT). This reverse engineering approach showed accurate and realistic results based on micro-CT and HR-peripheral quantitative CT images. However, its voxel size dependency, reproducibility and sensitivity still need to be investigated, which is the purpose of this study. Voxel size dependency was tested on cadaveric distal radii with micro-CT images scanned at 25 µm and downscaled to 50, 61, 75, 82, 100, 125 and 150 µm. Reproducibility was calculated with repeated in vitro as well as in vivo HR-pQCT measurements at 82 µm. Sensitivity was defined using HR-pQCT images from women with fracture versus non-fracture, and low versus high bone volume fraction, expecting similar and different loading histories, respectively. Our results indicate that the algorithm is voxel size independent within an average (maximum) error of 8.2% (32.9%) at 61 µm, but that the dependency increases considerably at voxel sizes bigger than 82 µm. In vitro and in vivo reproducibility are up to 4.5% and 10.2%, respectively, which is comparable to other in vitro studies and slightly higher than in other in vivo studies. Subjects with different bone volume fraction were clearly distinguished but not subjects with and without fracture. This is in agreement with bone adapting to customary loading but not to fall loads. We conclude that the in vivo bone loading estimation algorithm provides reproducible, sensitive and fairly voxel size independent results at up to 82 µm, but that smaller voxel sizes would be advantageous.


2006 ◽  
Vol 129 (4) ◽  
pp. 481-486 ◽  
Author(s):  
Chi Hyun Kim ◽  
Henry Zhang ◽  
George Mikhail ◽  
Dietrich von Stechow ◽  
Ralph Müller ◽  
...  

Microimaging based finite element analysis is widely used to predict the mechanical properties of trabecular bone. The choice of thresholding technique, a necessary step in converting grayscale images to finite element models, can significantly influence the predicted bone volume fraction and mechanical properties. Therefore, we investigated the effects of thresholding techniques on microcomputed tomography (micro-CT) based finite element models of trabecular bone. Three types of thresholding techniques were applied to 16-bit micro-CT images of trabecular bone to create three different models per specimen. Bone volume fractions and apparent moduli were predicted and compared to experimental results. In addition, trabecular tissue mechanical parameters and morphological parameters were compared among different models. Our findings suggest that predictions of apparent mechanical properties and structural properties agree well with experimental measurements regardless of the choice of thresholding methods or the format of micro-CT images.


1999 ◽  
Vol 32 (3) ◽  
pp. 323-326 ◽  
Author(s):  
Ming Ding ◽  
Anders Odgaard ◽  
Ivan Hvid

Author(s):  
Cesare Ciani ◽  
Paula A. Ramirez Marin ◽  
Stephen B. Doty ◽  
Susannah P. Fritton

Estrogen depletion has been shown to cause bone loss in the proximal metaphysis of the rat tibia [1,2]. A decrease in bone volume fraction is frequently reported, yet there is little analysis in the literature related to changes in microporosities during osteoporosis. Our recent work quantifying microporosity changes due to estrogen depletion has shown an increase in the lacunar-canalicular porosity surrounding osteocytes in the proximal metaphysis of the rat tibia [3].


2019 ◽  
Vol 15 (1) ◽  
pp. 65-68
Author(s):  
Nurin Nadzlah Abu Bakar ◽  
Basri Saidi ◽  
Lyana Shahirah Mohamad Yamin

Micro-CT is one of the best modalities in assessing bone morphology and microarchitecture in small animal models. Voxel size is directly related to the image resolution as it influences the bone morphology results. The purpose of this study was to assess the effects of t different thicknesses of structures on the trabecular bone qualitative parameters. It was also to find out the most appropriate voxel size when scanning a certain or specific body part with different thicknesses. Five BALB-C breed mice carcasses were scanned using two different voxel sizes of 18 and 35 µm. The scanning acquisition times were recorded to be compared and the trabecular bone parameters measurements were taken. Both trabecular number and trabecular separation were increased in thicker structures meanwhile bone volume fraction and trabecular thickness values were inconsistent with the increment of the structure thickness. The bone volume fraction, trabecular thickness and trabecular separation were higher in larger voxel size and vice versa for trabecular number. The scanning acquisition time has no apparent correlation with the trabecular bone parameters. The thickness of the bone structure did affect trabecular number and trabecular separation significantly but less affecting bone volume fraction and trabecular thickness. All trabecular bone parameters were found affected by the size of scanning voxel size used. The usage of 35 µm voxel was more recommended than 18 µm to save time and give out less radiation dose to specimen unless the detailed features of the trabecular pattern was very important.