Numerical and Experimental Study on the Cavitating Flow Characteristics of Pressurized Liquid Nitrogen in a Horizontal Rectangular Nozzle

2004 ◽  
Vol 127 (4) ◽  
pp. 515-524 ◽  
Author(s):  
Jun Ishimoto ◽  
Masahiro Onishi ◽  
Kenjiro Kamijo

The thermodynamic effect on cryogenic cavitating flow characteristics of pressurized liquid nitrogen in a horizontal rectangular nozzle is precisely investigated by numerical analysis based on an unsteady thermal nonequilibrium two-fluid model and by flow visualization measurement. According to the numerical and experimental study, the sufficiently useful results are proposed to realize the further development and high performance of a type of cryogenic two-phase cooling system. It is numerically and experimentally found that the inception of cryogenic cavitation occurs and the cavity grows in the vicinity of the wall surface of the inlet throat section. It is also found that the continuous process and behavior of cavitation inception, cloud cavity growth, and gas phase diffusion behavior with time in pressurized liquid nitrogen are dominated not only by several additional forces in the gas-phase momentum equation, but also by the thermodynamic effect that acts on the cavitation bubbles due to the inherent properties of cryogenic fluid. Especially under conditions of the same temperature and same aspect ratio of the cloud cavity, similar generating behavior of cavitation can be often found in the high Reynolds number region in spite of large cavitation number.

2003 ◽  
Author(s):  
Jun Ishimoto ◽  
Masahiro Onishi ◽  
Takashi Tokumasu ◽  
Kenjiro Kamijo

The fundamental characteristics of the two-dimensional cavitating flow of liquid nitrogen through a horizontal rectangular nozzle are numerically and experimentally investigated to realize the further development and high performance of new multiphase cryogenic fluid applications. First, the governing equations of the cavitating flow of liquid nitrogen based on the unsteady thermal nonequilibrium two-fluid model are presented, and several flow characteristics are numerically calculated, taken into account the thermodynamic effect of cryogenic conditions. Next, the flow visualization measurement on unsteady cavitating flow of liquid nitrogen through a rectangular nozzle installed in a horizontal duct is carried out to clarify the basic cryogenic two-phase flow structure and fundamental characteristics of the transient growth process of cryogenic cloud cavitation.


2020 ◽  
Vol 36 (1) ◽  
pp. 88-94
Author(s):  
Gao Xu ◽  
Chen Hong ◽  
Zhu Jiakai ◽  
Wang Shunhao ◽  
Zhang Xiaobin

Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4292
Author(s):  
Danil Dobrynin ◽  
Zhiheng Song ◽  
Alexander Fridman

We report on an experimental study of nanosecond-pulsed plasma treatment of liquid nitrogen demonstrating synthesis of a highly energetic nitrogen material. Raman, FTIR analysis of gas phase products of decomposition, and the material explosion characteristics suggest synthesis of polymeric (amorphous) nitrogen compound which is stable at ambient pressure up to temperatures of about −150 °C. Addition of adsorbents with relatively large characteristic pore sizes (>5 nm) allows marginally improved recovery of the material as determined by temperature-dependent Raman measurements. By analyzing the shock wave propagation resulting from the explosions, we estimated the energy density of the material to be 13.3 ± 3.5 kJ/g, close to the previously predicted value for amorphous polymeric nitrogen.


Author(s):  
John G. Sheehan

The goal is to examine with high resolution cryo-SEM aqueous particulate suspensions used in coatings for printable paper. A metal-coating chamber for cryo-preparation of such suspensions was described previously. Here, a new conduction-cooling system for the stage and cold-trap in an SEM specimen chamber is described. Its advantages and disadvantages are compared to a convection-cooling system made by Hexland (model CT1000A) and its mechanical stability is demonstrated by examining a sample of styrene-butadiene latex.In recent high resolution cryo-SEM, some stages are cooled by conduction, others by convection. In the latter, heat is convected from the specimen stage by cold nitrogen gas from a liquid-nitrogen cooled evaporative heat exchanger. The advantage is the fast cooling: the Hexland CT1000A cools the stage from ambient temperature to 88 K in about 20 min. However it consumes huge amounts of liquid-nitrogen and nitrogen gas: about 1 ℓ/h of liquid-nitrogen and 400 gm/h of nitrogen gas. Its liquid-nitrogen vessel must be re-filled at least every 40 min.


2021 ◽  
Vol 108 ◽  
pp. 106377
Author(s):  
Mohammed Faheem ◽  
Aqib Khan ◽  
Rakesh Kumar ◽  
Sher Afghan Khan ◽  
Waqar Asrar ◽  
...  

2019 ◽  
Vol 125 ◽  
pp. 92-101 ◽  
Author(s):  
Shuaiwei Gu ◽  
Yuxing Li ◽  
Lin Teng ◽  
Cailin Wang ◽  
Qihui Hu ◽  
...  

2017 ◽  
Vol 125 ◽  
pp. 1037-1046 ◽  
Author(s):  
Bin Wang ◽  
Yonghua Huang ◽  
Jingyi Wu ◽  
Tianxiang Wang ◽  
Gang Lei

Sign in / Sign up

Export Citation Format

Share Document