Pressure Drop and Heat Transfer in Turbulent Duct Flow: A Two-Parameter Variational Method

1995 ◽  
Vol 117 (2) ◽  
pp. 289-295 ◽  
Author(s):  
N. Ghariban ◽  
A. Haji-Sheikh ◽  
S. M. You

A two-parameter variational method is introduced to calculate pressure drop and heat transfer for turbulent flow in ducts. The variational method leads to a Galerkin-type solution for the momentum and energy equations. The method uses the Prandtl mixing length theory to describe turbulent shear stress. The Van Driest model is compared with experimental data and incorporated in the numerical calculations. The computed velocity profiles, pressure drop, and heat transfer coefficient are compared with the experimental data of various investigators for fully developed turbulent flow in parallel plate ducts and pipes. This analysis leads to development of a Green’s function useful for solving a variety of conjugate heat transfer problems.

Author(s):  
Sassan Etemad ◽  
Bengt Sunde´n

Turbulent flow and thermal field were predicted in a square-sectioned 180° bend at a Reynolds number of 56000. Suga’s low-Re cubic k-ε model [5–6] and the RSM [7–8] were used. The results were compared to experimental data [1]. Identical inlet boundary conditions were used in both cases. The inlet length impact on the flow-heat transfer in the bend was investigated. The velocities are higher near the inner wall and lower near the outer wall when a short inlet section is used. As the inlet length increases, the boundary layer grows thicker and the pressure-driven secondary vortex near the side wall becomes stronger. This vortex contributes significantly to the mixing process and heat transfer. It also alters the velocity distribution to a higher velocity near the outer wall and a lower velocity near the inner wall. When using a very long inlet length the vortex grows so strong that it generates a second counter-rotating vortex which isolates the fluid near the inner wall and prevents from further mixing. Consequently the local Nusselt number decreases. Both models reproduced the experimental data fairly well. Suga’s model performed better and converged without problems. It is believed that Suga’s model would be more suitable for industrial applications.


Author(s):  
Guoping Xu ◽  
Henry Jung

Several analytical models to predict heat transfer and pressure drop performance for parallel plate fin heat sinks are available in the literature. However, the experimental data to validate these models are very limited especially for high fin density heat sinks. In this paper, a new method is proposed to predict thermal performance in both laminar flow and turbulent flow. This method and other models selected from the literature have been compared to the test data. Experimental investigations were conducted with fully-duct flow for parallel plate fin heat sinks to measure overall thermal resistance and pressure drop. Three heat sinks with different fin materials and fin configurations are tested. We conclude by recommending some of the analytical methods for engineering applications by comparing the test data with predictions.


2011 ◽  
Vol 18 (6) ◽  
pp. 491-502 ◽  
Author(s):  
Andrew Mintu Sarkar ◽  
M. A. Rashid Sarkar ◽  
Mohammad Abdul Majid

2011 ◽  
Vol 133 (6) ◽  
Author(s):  
Simone Mancin ◽  
Claudio Zilio ◽  
Luisa Rossetto ◽  
Alberto Cavallini

Because of their interesting heat transfer and mechanical properties, metal foams have been proposed for several different applications, thermal and structural. This paper aims at pointing out the effective thermal fluid dynamic behavior of these new enhanced surfaces, which present high heat transfer area per unit of volume at the expense of high pressure drop. The paper presents the experimental heat transfer and pressure drop measurements relative to air flowing in forced convection through four different aluminum foams, when electrically heated. The tested aluminum foams present 5, 10, 20 and 40 PPI (pores per inch), porosity around 0.92–0.93, and 0.02 m of foam core height. The experimental heat transfer coefficients and pressure drops have been obtained by varying the air mass flow rate and the electrical power, which has been set at 25.0 kW m−2, 32.5 kW m−2, and 40.0 kW m−2. The results have been compared against those measured for 40 mm high samples, in order to study the effects of the foam core height on the heat transfer. Moreover, predictions from two recent models are compared with heat transfer coefficient and pressure drop experimental data. The predictions are in good agreement with experimental data.


Author(s):  
Han Wang ◽  
Qincheng Bi ◽  
Linchuan Wang ◽  
Haicai Lv ◽  
Laurence K. H. Leung

An experiment has recently been performed at Xi’an Jiaotong University to study the wall temperature and pressure drop at supercritical pressures with upward flow of water inside a 2×2 rod bundle. A fuel-assembly simulator with four heated rods was installed inside a square channel with rounded corner. The outer diameter of each heated rod is 8 mm with an effective heated length of 600 mm. Experimental parameters covered the pressure of 23–28 MPa, mass flux of 350–1000 kg/m2s and heat flux on the rod surface of 200–1000 kW/m2. According to the experimental data, it was found that the circumferential wall temperature distribution of a heated rod is not uniform. The temperature difference between the maximum and the minimum varies with heat flux and/or mass flux. Heat transfer characteristics of supercritical water in bundle were discussed with respect to various heat fluxes. The effect of heat flux on heat transfer in rod bundles is similar with that in tubes or annuli. In addition, flow resistance reflected in the form of pressure loss has also been studied. Experimental results showed that the total pressure drop increases with bulk enthalpy and mass flux. Four heat transfer correlations developed for supercritical pressures water were compared with the present test data. Predictions of Jackson correlation agrees closely with the experimental data.


Author(s):  
Brundaban Patro ◽  
Kiran K Kupireddi ◽  
Jaya K Devanuri

The current paper deals with the studies of heat transfer and pressure drop through a horizontal, adiabatic pipe, having gas–solid flows. The inlet air temperature is 443 K, whereas the inlet solid temperature is 308 K. The numerical results are compared with the benchmark experimental data and are agreed satisfactorily. The influences of solid loading ratio, solid diameter and gas velocity on Nusselt number and pressure drop have been studied. The Nusselt number decreases and the pressure drop increases with an increase in the solid diameter. The Nusselt number decreases with an increase in the solid loading ratio at a lower solid diameter of 100 µm. However, at a higher value of solid diameter of 200 µm, the Nusselt number first decreases up to a specific solid loading ratio, and after that, it increases. The pressure drop results show different behaviours with the solid loading ratio. Both the Nusselt number and pressure drop increase with the gas velocity. Finally, a correlation is generated to calculate the two-phase Nusselt number.


1979 ◽  
Vol 101 (2) ◽  
pp. 211-216 ◽  
Author(s):  
N. Cur ◽  
E. M. Sparrow

The heat transfer and pressure drop characteristics for an array of colinear, equally spaced plates aligned parallel to the flow in a flat rectangular duct have been studied experimentally. The periodic interruptions (i.e., the gaps between the plates) preclude the attainment of hydrodynamic and thermal development of the type that is encountered in conventional duct flows, but a periodic fully developed regime can exist. Measurements of the heat transfer coefficients for the successive plates of the array affirmed the periodically developed regime and demonstrated the developmental pattern leading to its attainment. The thickness of the plates in the array was varied parametrically. In general, the Nusselt number increases with plate thickness. Thickness-related increases in the fully developed Nusselt number of up to 65 percent were encountered. The presence of the interruptions serves to augment the heat transfer coefficients. In the fully turbulent regime, the heat transfer coefficients are on the order of twice those for a conventional duct flow. The pressure drop also increases with the plate thickness.