Three-Dimensional Finite Element Simulations of the Dynamic Response of a Fingertip to Vibration

2008 ◽  
Vol 130 (5) ◽  
Author(s):  
John Z. Wu ◽  
Kristine Krajnak ◽  
Daniel E. Welcome ◽  
Ren G. Dong

Although excessive dynamic deformation of the soft tissues in the fingertip under vibration loading is thought to induce hand-arm vibration syndrome, the in vivo distributions of the dynamic stress/strain of the tissues in the fingertip under vibration conditions have not been studied because they cannot be measured experimentally. In the present study, we analyzed the dynamic responses of a fingertip to vibrations by extending our previously proposed three-dimensional finite element (FE) model. The FE model of the fingertip contains the essential anatomical structures of a finger, such as skin layers (dermis and epidermis), subcutaneous tissue, bone, and nail. Our analysis indicated that the fingertip has a major local resonance around 100Hz and that the vibration displacement in the soft tissues under the nail bed is less than 10% of those in the finger pad for all precompression levels and vibration range. The resonant frequency of the fingertip was found to increase from 88Hzto125Hz with the static precompression increasing from 0.5mmto2.0mm. These results suggest that structural and functional changes in vascular function will likely initiate from the fingerpad, the location that undergoes the greatest deformation during vibration exposure. The current predictions are qualitatively consistent with the physiological data collected from workers with vibration white finger.

2017 ◽  
Vol 7 ◽  
pp. 219-223
Author(s):  
Beril Demir Karamanli ◽  
Hülya Kılıçoğlu ◽  
Armagan Fatih Karamanli

Aims The aim of this study is to evaluate the effects of the chincup appliance used in the treatment of Class III malocclusions, not only on the mandible or temporomandibular joint (TMJ) but also on all the craniofacial structures. Materials and Methods Chincup simulation was performed on a three-dimensional finite element (FE) model. 1000 g (500 g per side) force was applied in the direction of chin-condyle head. Nonlinear FE analysis was used as the numerical analysis method. Results By the application of chincup, stresses were distributed not only on TMJ or mandible but also on the circummaxillary sutures and other craniofacial structures. Conclusions Clinical changes obtained by chincup treatment in Class III malocclusions are not limited by only mandible. It was seen that also further structures were affected.


2012 ◽  
Vol 446-449 ◽  
pp. 837-840
Author(s):  
Yu Zhao ◽  
Shu Fang Yuan ◽  
Jian Wei Zhang

The underwater structure of power house is major structure under the dynamic loads of unit. The vibration problem is very common in operation. So the structures should have sufficient stiffness to resist dynamic loads of unit. This paper establishes three-dimensional finite element models with finite element analysis software—ANSYS. Dynamic characteristics of the power house and dynamic responses of structure under earthquake are analyzed. The results of the computation show that fluid-solid coupling may be ignored when studying dynamic characteristics of structures of the underground power house.


Author(s):  
Kazuo Ogawa ◽  
Nobuyoshi Yanagida ◽  
Koichi Saito

Residual stress distribution in an oblique nozzle jointed to a vessel with J-groove welds was analyzed using a three-dimensional finite element method. All welding passes were considered in a 180-degree finite element (FE) model with symmetry. Temperature and stress were modeled for simultaneous bead laying. To determine residual stress distributions at the welds experimentally, a mock-up specimen was manufactured. The analytical results show good agreement with the experimental measurement data, indicating that FE modeling is valid.


Author(s):  
Mingya Chen ◽  
Weiwei Yu ◽  
Fei Xue ◽  
Francis Ku ◽  
Zhilin Chen ◽  
...  

The objective of this study is to correct installation non-conformance of a surge line using the excavation and re-weld method which is widely used in nuclear power plants. The surge line with a backslope was not at the required design level after initial installation. In order to solve the problem, a repairing technology is shown as follows: the weld was successively excavated and welded again while the surge line slope was corrected with the help of jacks. Because many of the degradation mechanisms relevant to power plant components can be accelerated by the presence of welding residual stresses (WRS), the WRS caused by the repairing process need to be studied. In this paper, the WRS simulation technique employed in this project is sophisticated. It utilizes a 3-D finite element (FE) model, and simulates the weld sequencing and excavation. Moreover, the WRS simulation performed in this project not only uses the un-axisymmetric model, but also considers the deformation caused by the external jacking loads. The results show that the repairing process is effective, and strain damage induced by the welding repair is also acceptable.


Author(s):  
Sung Jin Yoon ◽  
Tae Jin Shin ◽  
Jae Sang Lee ◽  
Sang Moo Hwang

This paper describes in detail the deformation behavior of the rolls and strip predicted from the three-dimensional finite element analysis of skin-pass rolling. The predictions are made on the basis of the coupled analysis of elastic deformation of the rolls and elastic–plastic deformation of the strip. Predictions from the proposed finite element (FE) model are compared with experimental data from laboratory-scale cold rolling mills. Then, proposed are models for the prediction of the roll force profile and for the prediction of the residual stress profile. The prediction accuracy of the models is examined through comparison with the predictions from the FE model.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Namkeun Kim ◽  
You Chang ◽  
Stefan Stenfelt

A three-dimensional finite-element (FE) model of a human dry skull was devised for simulation of human bone-conduction (BC) hearing. Although a dry skull is a simplification of the real complex human skull, such model is valuable for understanding basic BC hearing processes. For validation of the model, the mechanical point impedance of the skull as well as the acceleration of the ipsilateral and contralateral cochlear bone was computed and compared to experimental results. Simulation results showed reasonable consistency between the mechanical point impedance and the experimental measurements when Young’s modulus for skull and polyurethane was set to be 7.3 GPa and 1 MPa with 0.01 and 0.1 loss factors at 1 kHz, respectively. Moreover, the acceleration in the medial-lateral direction showed the best correspondence with the published experimental data, whereas the acceleration in the inferior-superior direction showed the largest discrepancy. However, the results were reasonable considering that different geometries were used for the 3D FE skull and the skull used in the published experimental study. The dry skull model is a first step for understanding BC hearing mechanism in a human head and simulation results can be used to predict vibration pattern of the bone surrounding the middle and inner ear during BC stimulation.


Author(s):  
P M Cattaneo ◽  
M Dalstra ◽  
L H Frich

Three-dimensional finite element analysis is one of the best ways to assess stress and strain distributions in complex bone structures. However, accuracy in the results may be achieved only when accurate input information is given. A semi-automated method to generate a finite element (FE) model using data retrieved from computed tomography (CT) was developed. Due to its complex and irregular shape, the glenoid part of a left embalmed scapula bone was chosen as working material. CT data were retrieved using a standard clinical CT scanner (Siemens Somatom Plus 2, Siemens AG, Germany). This was done to produce a method that could later be utilized to generate a patient-specific FE model. Different methods of converting Hounsfield unit (HU) values to apparent densities and subsequently to Young's moduli were tested. All the models obtained were loaded using three-dimensional loading conditions taken from literature, corresponding to an arm abduction of 90°. Additional models with different amounts of elements were generated to verify convergence. Direct comparison between the models showed that the best method to convert HU values directly to apparent densities was to use different equations for cancellous and cortical bone. In this study, a reliable method of determining both geometrical data and bone properties from patient CT scans for the semi-automated generation of an FE model is presented.


2003 ◽  
Vol 1256 ◽  
pp. 349-355 ◽  
Author(s):  
Y. Tillier ◽  
A. Paccini ◽  
M. Durand-Reville ◽  
F. Bay ◽  
J.-L. Chenot

2008 ◽  
Vol 59 ◽  
pp. 116-119
Author(s):  
Joshim Ali ◽  
Derek Buckthorpe ◽  
Allister Cheyne ◽  
Johar Farooqi ◽  
Paul M. Mummery

Three-dimensional finite element (FE) methods are used to predict the Young’s modulus of two types of 2D woven carbon/carbon composites. Tensile tests are performed to validate the predictions. The results indicate that a novel image-based route in generating FE meshes gave strong agreement with experimental data, while a comparative unit cell FE model of the structure was found to be poorer. The differences between the image-based and unit cell methodologies were the consideration of the finer architectures of the composites and their porosity. The image-based approach highlighted true porosity in the structure due to meshes forming directly from X-ray tomographic data. However, the finer fibre architectures of the composites were compromised because of limitations in the pixel resolutions employed during the initial scanning process. In comparison, the unit cell models were based solely on idealisations of the composite microstructure, in which porosity was neglected.


2004 ◽  
Vol 127 (3) ◽  
pp. 484-491 ◽  
Author(s):  
Jing Shi ◽  
C. Richard Liu

A material softening model based on thermal activation energy has been successfully established through tempering experiments in the first part of this study. To apply the model to predicting material softening in hard turned surfaces, the thermal history of work material is needed. In this part, a three-dimensional finite element (FE) model of machining hardened 52100 steel is constructed, and coupled thermal-stress analysis is performed to obtain the material thermal history. Then the material softening model uses the computed thermal history as input to predict the material hardness profiles along the depth into the machined surfaces. Overall, the prediction precisely catches the trend of hardness change along depth and agrees reasonably well with the hardness measurement. What’s more, the sensitivity of material softening to cutting parameters is investigated both quantitatively and qualitatively. Within the investigation range, it is observed that the increase of tool flank wear and feed rate produces severe material softening and a deeper softened layer, while the increase of cutting speed causes significant softening to the surface material but hardly changes the softened depth.


Sign in / Sign up

Export Citation Format

Share Document