Performance of a Closed-Tube Aerosyphon With Large Length-Diameter Ratios

1989 ◽  
Vol 111 (4) ◽  
pp. 337-343
Author(s):  
G. S. H. Lock ◽  
J. D. Kirchner

The paper reports an experimental investigation of heat transfer in the closed-tube aerosyphon (aerated-thermosyphon) for a range of conditions representative of northern field applications. In particular, attention is focused on the effect of using tubes with heated lengths not only greater than the cooled lengths, but very much greater than the tube diameter. Using three heated sections and one cooled section, the geometry of the device has been varied systematically with 10 < LH/d < 50 and 1 < LH/LC < 20. For any given geometry, the effect of air bubbling rate has been studied in the range of 0 < V˙ < 5 × 10−5 m3/S. Using these ranges it has been possible to make comparisons with other thermosyphon and aerosyphon data. The results indicate that heat transfer coefficients are reduced by increasing either length-diameter ratio or heated-cooled length ratio. They also reveal that, in general terms, the aerosyphon is almost an order-of-magnitude more effective than the single-phase thermosyphon. Some obervations on the flow regimes are offered, and an empirical correlation is presented.

1989 ◽  
Vol 111 (1) ◽  
pp. 22-28 ◽  
Author(s):  
G. S. H. Lock ◽  
G. A. Simpson

The experimental work reported here is concerned with the single-phase closed thermosyphon under conditions which are appropriate to a northern application: large length-diameter ratios and heated lengths much greater than cooled lengths. The purpose is twofold: to generate empirical heat transfer data which represent the conservative lower limit of performance (in the absence of boiling or bubbling); and to reveal the thermal and momentum exchange mechanisms which operate at the junction of the heated and cooled sections. The apparatus consisted of a 102-mm-dia, vertical steel pipe of overall length varying from 2 m to 6 m. The lower section of the pipe was heated by means of electric-resistive tape, and the upper section cooled by means of a water jacket. Heat transfer data, plotted in the usual form of Nusselt number versus the quotient of the Rayleigh number and the length-diameter ratio, show the effect of geometry. This data was obtained for 10 ≤ LH/d ≤ 50, and 1 ≤ LH/Lc ≤ 20. An empirical correlation is developed.


Author(s):  
Todd M. Bandhauer ◽  
Taylor A. Bevis

The principle limit for achieving higher brightness of laser diode arrays is thermal management. State of the art laser diodes generate heat at fluxes in excess of 1 kW cm−2 on a plane parallel to the light emitting edge. As the laser diode bars are packed closer together, it becomes increasingly difficult to remove large amounts of heat in the diminishing space between neighboring diode bars. Thermal management of these diode arrays using conduction and natural convection is practically impossible, and, therefore, some form of forced convective cooling must be utilized. Cooling large arrays of laser diodes using single-phase convection heat transfer has been investigated for more than two decades by multiple investigators. Unfortunately, either large fluid temperature increases or very high flow velocities must be utilized to reject heat to a single phase fluid, and the practical threshold for single phase convective cooling of laser diodes appears to have been reached. In contrast, liquid-vapor phase change heat transport can occur with a negligible increase in temperature and, due to a high enthalpy of vaporization, at comparatively low mass flow rates. However, there have been no prior investigations at the conditions required for high brightness edge emitting laser diode arrays: >1 kW cm−2 and >10 kW cm−3. In the current investigation, flow boiling heat transfer at heat fluxes up to 1.1 kW cm−2 was studied in a microchannel heat sink with plurality of very small channels (45 × 200 microns) using R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio in the vicinity of the laser diode. To characterize the heat transfer performance, a test facility was constructed that enabled testing over a range of fluid saturation temperatures (15°C to 25°C). Due to the very small geometric features, significant heat spreading was observed, necessitating numerical methods to determine the average heat transfer coefficient from test data. This technique is crucial to accurately calculate the heat transfer coefficients for the current investigation, and it is shown that the analytical approach used by many previous investigations requires assumptions that are inadequate for the very small dimensions and heat fluxes observed in the present study. During the tests, the calculated outlet vapor quality exceeded 0.6 and the base heat flux reached a maximum of 1.1 kW cm−2. The resulting experimental heat transfer coefficients are found to be as large a 58.1 kW m−2 K−1 with an average uncertainty of ±11.1%, which includes uncertainty from all measured and calculated values, required assumptions, and geometric discretization error from meshing.


1996 ◽  
Vol 118 (1) ◽  
pp. 21-26 ◽  
Author(s):  
David Copeland

Experimental measurements of multiple nozzle submerged jet array impingement single-phase and boiling heat transfer were made using FC-72 and 1 cm square copper pin fin arrays, having equal width and spacing of 0.1 and 0.2 mm, with aspect ratios from 1 to 5. Arrays of 25 and 100 nozzles were used, with diameters of 0.25 to 1.0 mm providing nozzle area from 5 to 20 mm2 (5 to 20% of the heat source base area). Flow rates of 2.5 to 10 cm3/s (0.15 to 0.6 l/min) were studied, with nozzle velocities from 0.125 to 2 m/s. Single nozzles and smooth surfaces were also evaluated for comparison. Single-phase heat transfer coefficients (based on planform area) from 2.4 to 49.3 kW/m2 K were measured, while critical heat flux varied from 45 to 395 W/cm2. Correlations of the single-phase heat transfer coefficient and critical heat flux as functions of pin fin dimensions, number of nozzles, nozzle area and liquid flow rate are provided.


Author(s):  
M. W. Alnaser ◽  
K. Spindler ◽  
H. Mu¨ller-Steinhagen

A test rig was constructed to investigate flow boiling in an electrically heated horizontal mini-channel array. The test section is made of copper and consists of twelve parallel mini-channels. The channels are 1 mm deep, 1 mm wide and 250 mm long. The test section is heated from underneath with six cartridge heaters. The channels are covered with a glass plate to allow visual observations of the flow patterns using a high-speed video-camera. The wall temperatures are measured at five positions along the channel axis with two resistance thermometers in a specified distance in heat flow direction. Local heat transfer coefficients are obtained by calculating the local heat flux. The working fluids are deionised water and ethanol. The experiments were performed under near atmospheric pressure (0.94 bar to 1.2 bar absolute). The inlet temperature was kept constant at 20°C. The measurements were taken for three mass fluxes (120; 150; 185 kg/m2s) at heat fluxes from 7 to 375 kW/m2. Heat transfer coefficients are presented for single phase forced convection, subcooled and saturated flow boiling conditions. The heat transfer coefficient increases slightly with rising heat flux for single phase flow. A strong increase is observed in subcooled flow boiling. At high heat flux the heat transfer coefficient decreases slightly with increasing heat flux. The application of ethanol instead of water leads to an increase of the surface temperature. At the same low heat flux flow boiling heat transfer occurs with ethanol, but in the experiments with water single phase heat transfer is still dominant. It is because of the lower specific heat capacity of ethanol compared to water. There is a slight influence of the mass flux in the investigated parameter range. The pictures of a high-speed video-camera are analysed for the two-phase flow-pattern identification.


2013 ◽  
Vol 135 (7) ◽  
Author(s):  
Mehmed Rafet Özdemir ◽  
Ali Koşar

The pressure drop and heat transfer due to the flow of de-ionized water at high mass fluxes in microtubes of ∼ 254 μm and ∼ 685 μm inner diameters is investigated in the laminar, transition and the turbulent flow regimes. The flow is hydrodynamically fully developed and thermally developing. The experimental friction factors and heat transfer coefficients are respectively predicted to within ±20% and ±30% by existing open literature correlations. Higher single phase heat transfer coefficients were obtained with increasing mass fluxes, which is motivating to operate at high mass fluxes and under thermally developing flow conditions. The transition to turbulent flow and friction factors for both laminar and turbulent conditions were found to be in agreement with existing theory. A reasonable agreement was present between experimental results and theoretical predictions recommended for convective heat transfer in thermally developing flows.


1993 ◽  
Vol 115 (4) ◽  
pp. 912-920 ◽  
Author(s):  
J.-C. Han ◽  
Y.-M. Zhang ◽  
Kathrin Kalkuehler

The influence of uneven wall temperature on the local heat transfer coefficient in a rotating, two-pass, square channel with smooth walls is investigated for rotation numbers from 0.0352 to 0.352 by varying Reynolds numbers from 25,000 to 2500. The two-pass square channel, composed of 12 isolated copper sections, has a length-to-hydraulic diameter ratio of 12. The mean rotating radius to the channel hydraulic diameter ratio is kept at a constant value of 30. Three cases of thermal boundary conditions are studied: (A) four walls at the same temperature, (B) four walls at the same heat flux, and (C) trailing wall hotter than leading with side walls unheated and insulated. The results for case A of four walls at the same temperature show that the first channel (radial outward flow) heat transfer coefficients on the leading surface are much lower than that of the trailing surface due to the combined effect of Coriolis and buoyancy forces. The second channel (radial inward flow) heat transfer coefficients on the leading surface are higher than that of the trailing surface. The difference between the heat transfer coefficients for the leading and trailing surface in the second channel is smaller than that in the first channel due to the opposite effect of Coriolis and buoyancy forces in the second channel. However, the heat transfer coefficients on each wall in each channel for cases B and C are higher than case A because of interactions between rotation-induced secondary flows and uneven wall temperatures in cases B and C. The results suggest that the effect of uneven wall temperatures on local heat transfer coefficients in the second channel is greater than that in the first channel.


1991 ◽  
Vol 113 (1) ◽  
pp. 71-78 ◽  
Author(s):  
J. Stevens ◽  
B. W. Webb

The purpose of this investigation was to characterize local heat transfer coefficients for round, single-phase free liquid jets impinging normally against a flat uniform heat flux surface. The problem parameters investigated were jet Reynolds number Re, nozzle-to-plate spacing z, and jet diameter d. A region of near-constant Nusselt number was observed for the region bounded by 0≤r/d≤0.75, where r is the radial distance from the impingement point. The local Nusselt number profiles exhibited a sharp drop for r/d > 0.75, followed by an inflection and a slower decrease there-after. Increasing the nozzle-to-plate spacing generally decreased the heat transfer slightly. The local Nusselt number characteristics were found to be dependent on nozzle diameter. This was explained by the influence of the free-stream velocity gradient on local heat transfer, as predicted in the classical analysis of infinite jet stagnation flow and heat transfer. Correlations for local and average Nusselt numbers reveal an approximate Nusselt number dependence on Re1/3.


Author(s):  
A. M. Ai Dabagh ◽  
G. E. Andrews

The differences in the heat transfer coefficient between the pin and the wall in pin-fin heat transfer was determined for three pin length to diameter ratios. A staggered pin-fin array was used with a 50% duct flow blockage by the pins. The axial pitch-to-pin diameter ratio, X/D, was 1.5 and the transverse pitch-to-diameter ratio, S/D, was 2.0. Three pin length-to-diameter ratios, T/D, of 0.7. 1.0 and 2.2 were investigated. The mean heat transfer coefficient results were very similar to previous work for similar geometries. The axial variation of heat transfer coefficient showed this to be fairly uniform with a small peak at the fourth row. Around each pin four measurements of the heat transfer coefficients were made with four on the fin surface at each end. Thus 12 local heat transfer coefficients were made per pin-fin. These showed that for all three geometries the wall or fin heat transfer was always greater by 15–35% than the pin for the same velocity and Re.