EXPERIMENTAL STUDY OF THE ENDWALL HEAT TRANSFER OF A TRANSONIC NOZZLE GUIDE VANE WITH UPSTREAM JET PURGE COOLING PART 1 - EFFECT OF DENSITY RATIO

2021 ◽  
pp. 1-36
Author(s):  
Shuo Mao ◽  
Ridge A. Sibold ◽  
Wing Ng ◽  
Zhigang LI ◽  
Bo Bai ◽  
...  

Abstract Nozzle guide vane platforms often employ complex cooling schemes to mitigate the ever-increasing thermal loads on endwall. This study analyzes, experimentally and numerically, and describes the effect of coolant to mainstream blowing ratio, momentum ratio and density ratio for a typical axisymmetric converging nozzle guide vane platform with an upstream doublet staggered, steep-injection, cylindrical hole purge cooling scheme. Nominal flow conditions were engine-representative and as follows: Maexit = 0.85, Reexit,Cax = 1.5×106 and an inlet large-scale freestream turbulence intensity of 16%. Two blowing ratios were investigated, each corresponding to the design condition and its upper extrema at M = 2.5 and 3.5, respectively. For each blowing ratio, the coolant to mainstream density ratio was varied between DR=1.2, representing typical experimental neglect of coolant density, and DR=1.95, representative of typical engine conditions. The results show that with a fixed coolant-to-mainstream blowing ratio, the density ratio plays a vital role in the coolant-mainstream mixing and the interaction between coolant and horseshoe vortex near the vane leading edge. A higher density ratio leads to a better coolant coverage immediately downstream of the cooling holes but exposes the in-passage endwall near the pressure side. It also causes the in-passage coolant coverage to decay at a higher rate in the flow direction. From the results gathered, both density ratio and blowing ratio should be considered for accurate testing, analysis, and prediction of purge jet cooling scheme performance.

Author(s):  
Shuo Mao ◽  
Ridge A. Sibold ◽  
Stephen Lash ◽  
Wing F. Ng ◽  
Hongzhou Xu ◽  
...  

Abstract Nozzle guide vane platforms often employ complex cooling schemes to mitigate ever-increasing thermal loads on endwall. Understanding the impact of advanced cooling schemes amid the highly complex three-dimensional secondary flow is vital to engine efficiency and durability. This study analyzes and describes the effect of coolant to mainstream blowing ratio, momentum ratio and density ratio for a typical axisymmetric converging nozzle guide vane platform with an upstream doublet staggered, steep-injection, cylindrical hole jet purge cooling scheme. Nominal flow conditions were engine representative and as follows: Maexit = 0.85, Reexit/Cax = 1.5 × 106 and an inlet large-scale freestream turbulence intensity of 16%. Two blowing ratios were investigated, each corresponding to upper and lower engine extrema at M = 3.5 and 2.5, respectively. For each blowing ratio, the coolant to mainstream density ratio was varied between DR = 1.2, representing typical experimental neglect of coolant density, and DR = 1.95, representative of typical engine conditions. An optimal coolant momentum ratio between = 6.3 and 10.2 is identified for in-passage film effectiveness and net heat flux reduction, at which the coolant suppresses and overcomes secondary flows but imparts minimal turbulence and remains attached to endwall. Progression beyond this point leads to cooling effectiveness degradation and increased endwall heat flux. Endwall heat transfer does not scale well with one single parameter; increasing with increasing mass flux for the low density case but decreasing with increasing mass flux of high density coolant. From the results gathered, both coolant to mainstream density ratio and blowing ratio should be considered for accurate testing, analysis and prediction of purge jet cooling scheme performance.


2021 ◽  
pp. 1-34
Author(s):  
Shuo Mao ◽  
Ridge A. Sibold ◽  
Wing Ng ◽  
Zhigang LI ◽  
Bo Bai ◽  
...  

Abstract A misalignment between the combustor exit and the nozzle guide vane (NGV) platform commonly exists due to manufacturing tolerances and thermal transience. This study investigated, experimentally and computationally, the effect of the combustor-turbine misalignment on the heat transfer for an axisymmetric converging endwall with a jet purge cooling scheme at transonic conditions. The studies were conducted at engine-representative Maexit = 0.85, inlet turbulence intensity of 16%, Reexit,Cax = 1.5×106. A film cooling blowing ratio of 2.5 (design condition) and 3.5 and an engine-representative density ratio of 1.95 were used in the study. Three various step misalignments, combustor exit being 4.9% span higher than turbine inlet (backward-facing), no step (baseline), and combustor exit being 4.9% span lower than turbine inlet (forward-facing), were tested to demonstrate the misalignment effect on endwall heat transfer. Results indicated that the step misalignment affects the cooling performance by altering the interaction between the coolant and the cavity vortex, horseshoe vortex, and passage vortex. At the design blowing ratio of 2.5, the backward-facing step leads to increased coolant dissipation, causing the coolant to be later dominated by the passage vortex and leading to poor cooling performance. Meanwhile, a forward-facing step induced more coolant lift-off. At the blowing ratio of 3.5, the additional momentum ensures that enough coolant enters the passage to form a stable boundary layer. Therefore, the step misalignment no longer has a first-order effect.


Author(s):  
Ranjan Saha ◽  
Boris I. Mamaev ◽  
Jens Fridh ◽  
Björn Laumert ◽  
Torsten H. Fransson

Experiments are conducted to investigate the effect of the pre-history in the aerodynamic performance of a three-dimensional nozzle guide vane with a hub leading edge contouring. The performance is determined with two pneumatic probes (5 hole and 3 hole) concentrating mainly on the endwall. The investigated vane is a geometrically similar gas turbine vane for the first stage with a reference exit Mach number of 0.9. Results are compared for the baseline and filleted cases for a wide range of operating exit Mach numbers from 0.5 to 0.9. The presented data includes loading distributions, loss distributions, fields of exit flow angles, velocity vector and vorticity contour, as well as, mass-averaged loss coefficients. The results show an insignificant influence of the leading edge fillet on the performance of the vane. However, the pre-history (inlet condition) affects significantly in the secondary loss. Additionally, an oil visualization technique yields information about the streamlines on the solid vane surface which allows identifying the locations of secondary flow vortices, stagnation line and saddle point.


2015 ◽  
Vol 137 (8) ◽  
Author(s):  
Lamyaa A. El-Gabry ◽  
Ranjan Saha ◽  
Jens Fridh ◽  
Torsten Fransson

An experimental study has been performed in a transonic annular sector cascade of nozzle guide vanes (NGVs) to investigate the aerodynamic performance and the interaction between hub film cooling and mainstream flow. The focus of the study is on the endwalls, specifically the interaction between the hub film cooling and the mainstream. Carbon dioxide (CO2) has been supplied to the coolant holes to serve as tracer gas. Measurements of CO2 concentration downstream of the vane trailing edge (TE) can be used to visualize the mixing of the coolant flow with the mainstream. Flow field measurements are performed in the downstream plane with a five-hole probe to characterize the aerodynamics in the vane. Results are presented for the fully cooled and partially cooled vane (only hub cooling) configurations. Data presented at the downstream plane include concentration contour, axial vorticity, velocity vectors, and yaw and pitch angles. From these investigations, secondary flow structures such as the horseshoe vortex, passage vortex, can be identified and show the cooling flow significantly impacts the secondary flow and downstream flow field. The results suggest that there is a region on the pressure side (PS) of the vane TE where the coolant concentrations are very low suggesting that the cooling air introduced at the platform upstream of the leading edge (LE) does not reach the PS endwall, potentially creating a local hotspot.


2017 ◽  
Vol 139 (11) ◽  
Author(s):  
Ioanna Aslanidou ◽  
Budimir Rosic

This paper presents an experimental investigation of the concept of using the combustor transition duct wall to shield the nozzle guide vane leading edge. The new vane is tested in a high-speed experimental facility, demonstrating the improved aerodynamic and thermal performance of the shielded vane. The new design is shown to have a lower average total pressure loss than the original vane, and the heat transfer on the vane surface is overall reduced. The peak heat transfer on the vane leading edge–endwall junction is moved further upstream, to a region that can be effectively cooled as shown in previously published numerical studies. Experimental results under engine-representative inlet conditions showed that the better performance of the shielded vane is maintained under a variety of inlet conditions.


Author(s):  
Arun Kumar Pujari ◽  
Bhamidi Prasad ◽  
Nekkanti Sitaram

Experimental and computational heat transfer investigations are reported in the interior side of a nozzle guide vane (NGV) subjected to combined impingement and film cooling. The domain of study is a two dimensional five-vane cascade having four passages. Each vane has a chord length of 228 mm and the pitch distance between the vanes is 200 mm. The vane internal surface is cooled by dry air supplied through the two impingement inserts: the front and the aft. The mass flow through the impingement chamber is varied, for a fixed spacing (H) to jet diameter (d) ratio of 1.2. The surface temperature distributions, at certain locations of the vane interior, are measured by pasting strips of liquid crystal sheets. The vane interior surface temperature distribution is also obtained by computations carried out by using Shear stress transport (SST) k-ω turbulence model in the ANSY FLUENT-14 flow solver. The computational data are in good agreement with the measured values of temperature. The internal heat transfer coefficients are thence determined along the leading edge and the mid span region from the computational data.


Author(s):  
Arun Kumar Pujari ◽  
B. V. S. S. S. Prasad ◽  
Nekkanti Sitaram

Experimental and computational heat transfer investigations are reported on the interior side of a nozzle guide vane (NGV) subjected to combined impingement and film cooling. The domain of study is a two-dimensional five-vane cascade having a space chord ratio of 0.88. The vane internal surface is cooled by dry air, supplied through the two impingement inserts: the front and the aft. The blowing ratio (ρcVc/ρmVm) is varied systematically by varying the coolant mass flow through the impingement chamber and also by changing the mainstream Reynolds number, but by keeping a fixed spacing (H) to jet diameter (d) ratio of 1.2. The surface temperature distributions, at certain locations of the vane interior surface, are measured by pasting strips of liquid crystal sheets. The vane interior surface temperature distribution is also obtained by the computations carried out by using shear stress transport (SST) k–ω turbulence model in the flow solver ansys fluent-14. The computational data are in good agreement with the measured values of temperature. The internal heat transfer coefficients are thence determined from the computational data. The results show that, when the blowing ratio is increased by increasing the coolant flow rate, the average internal surface temperature decreases. However, when the blowing ratio is varied by increasing the mainstream Reynolds number, the internal surface temperature increases. Further, the temperature variations are different all along the internal surface from the leading edge to the trailing edge and are largely dependent on the coolant flow distributions on the internal as well as the external sides.


Author(s):  
A. A. Thrift ◽  
K. A. Thole ◽  
S. Hada

Heat transfer is a critical factor in the durability of gas turbine components, particularly in the first vane. An axisymmetric contour is sometimes used to contract the cross sectional area from the combustor to the first stage vane in the turbine. Such contouring can lead to significant changes in the endwall flows thereby altering the heat transfer. This paper investigates the effect of axisymmetric contouring on endwall heat transfer of a nozzle guide vane. Heat transfer measurements are performed on the endwalls of a planar and contoured passage whereby one endwall is modified with a linear slope in the case of the contoured passage. Included in this study is upstream leakage flow issuing from a slot normal to the inlet axis. Each of the endwalls within the contoured passage presents a unique flowfield. For the contoured passage, the flat endwall is subject to an increased acceleration through the area contraction while the contoured endwall includes both increased acceleration and a turning of streamlines due to the slope. Results indicate heat transfer is reduced on both endwalls of the contoured passage relative to the planar passage. In the case of all endwalls, increasing leakage mass flow rate leads to an increase in heat transfer near the suction side of the vane leading edge.


2002 ◽  
Vol 124 (3) ◽  
pp. 461-471 ◽  
Author(s):  
J. E. Sargison ◽  
S. M. Guo ◽  
M. L. G. Oldfield ◽  
G. D. Lock ◽  
A. J. Rawlinson

This paper presents the first experimental measurements on an engine representative nozzle guide vane, of a new film-cooling hole geometry, a con¯vergings¯lot-hole¯ or console. The patented console geometry is designed to improve the heat transfer and aerodynamic performance of turbine vane and rotor blade cooling systems. These experiments follow the successful validation of the console design in low-speed flat-plate tests described in Part 1 of this paper. Stereolithography was used to manufacture a resin model of a transonic, engine representative nozzle guide vane in which seven rows of previously tested fan-shaped film-cooling holes were replaced by four rows of consoles. This vane was mounted in the annular vane ring of the Oxford cold heat transfer tunnel for testing at engine Reynolds numbers, Mach numbers and coolant to mainstream momentum flux ratios using a heavy gas to simulate the correct coolant to mainstream density ratio. Heat transfer data were measured using wide-band thermochromic liquid crystals and a modified analysis technique. Both surface heat transfer coefficient and the adiabatic cooling effectiveness were derived from computer-video records of hue changes during the transient tunnel run. The cooling performance, quantified by the heat flux at engine temperature levels, of the console vane compares favourably with that of the previously tested vane with fan-shaped holes. The new console film-cooling hole geometry offers advantages to the engine designer due to a superior aerodynamic efficiency over the fan-shaped hole geometry. These efficiency measurements are demonstrated by results from midspan traverses of a four-hole pyramid probe downstream of the nozzle guide vane.


2014 ◽  
Vol 136 (7) ◽  
Author(s):  
Ranjan Saha ◽  
Boris I. Mamaev ◽  
Jens Fridh ◽  
Björn Laumert ◽  
Torsten H. Fransson

Experiments are conducted to investigate the effect of the prehistory in the aerodynamic performance of a three-dimensional nozzle guide vane with a hub leading edge contouring. The performance is determined with two pneumatic probes (five hole and three hole) concentrating mainly on the end wall. The investigated vane is a geometrically similar gas turbine vane for the first stage with a reference exit Mach number of 0.9. Results are compared for the baseline and filleted cases for a wide range of operating exit Mach numbers from 0.5 to 0.9. The presented data includes loading distributions, loss distributions, fields of exit flow angles, velocity vector, and vorticity contour, as well as mass-averaged loss coefficients. The results show an insignificant influence of the leading edge fillet on the performance of the vane. However, the prehistory (inlet condition) affects significantly in the secondary loss. Additionally, an oil visualization technique yields information about the streamlines on the solid vane surface, which allows identifying the locations of secondary flow vortices, stagnation line, and saddle point.


Sign in / Sign up

Export Citation Format

Share Document