Effect of Crossflows on the Discharge Coefficient of Film Cooling Holes With Varying Angles of Inclination and Orientation

Author(s):  
Michael Gritsch ◽  
Achmed Schulz ◽  
Sigmar Wittig

Measurements of discharge coefficients for five configurations of cylindrical film cooling hole geometries are presented. These comprise holes of varying angles of inclination (α= 30, 45, and 90deg) and orientation (γ= 0, 45, and 90deg) which are tested over a wide range of engine like conditions in terms of internal and external crossflow Mach numbers (Mam=0…1.2, Mac=0…0.6) as well as pressure ratios (ptc/pm=1…2.25). Results show that discharge coefficients do not solely depend on hole geometry but are also profoundly affected by the internal and external crossflow conditions. The effect of increasing the orientation angle on the discharge behavior is very similar to the effect of increasing the inclination angle. Both result in higher losses particularly at the cooling hole inlet while the losses at the hole exit are only slightly affected.

2001 ◽  
Vol 123 (4) ◽  
pp. 781-787 ◽  
Author(s):  
Michael Gritsch ◽  
Achmed Schulz ◽  
Sigmar Wittig

Measurements of discharge coefficients for five configurations of cylindrical film cooling hole geometries are presented. These comprise holes of varying angles of inclination (α=30, 45, and 90 deg) and orientation (γ=0, 45, and 90 deg), which are tested over a wide range of engine-like conditions in terms of internal and external crossflow Mach numbers (Mam=0…1.2,Mac=0…0.6) as well as pressure ratios ptc/pm=1…2.25. Results show that discharge coefficients do not depend solely on hole geometry, but are also profoundly affected by the internal and external crossflow conditions. The effect of increasing the orientation angle on the discharge behavior is very similar to the effect of increasing the inclination angle. Both result in higher losses, particularly at the cooling hole inlet while the losses at the hole exit are only slightly affected.


Author(s):  
M. Gritsch ◽  
A. Schulz ◽  
S. Wittig

This paper presents the discharge coefficients of three film-cooling hole geometries tested over a wide range of flow conditions. The hole geometries include a cylindrical hole and two holes with a diffuser shaped exit portion (i.e. a fanshaped and a laidback fanshaped hole). The flow conditions considered were the crossflow Mach number at the hole entrance side (up to 0.6), the crossflow Mach number at the hole exit side (up to 1.2), and the pressure ratio across the hole (up to 2). The results show that the discharge coefficient for all geometries tested strongly depends on the flow conditions (crossflows at hole inlet and exit, and pressure ratio). The discharge coefficient of both expanded holes was found to be higher than of the cylindrical hole, particularly at low pressure ratios and with a hole entrance side crossflow applied. The effect of the additional layback on the discharge coefficient is negligible.


2000 ◽  
Vol 123 (3) ◽  
pp. 593-600 ◽  
Author(s):  
D. A. Rowbury ◽  
M. L. G. Oldfield ◽  
G. D. Lock

This paper discusses large-scale, low-speed experiments that explain unexpected flow-interaction phenomena witnessed during annular cascade studies into the influence of external crossflow on film cooling hole discharge coefficients. More specifically, the experiments throw light on the crossover phenomenon, where the presence of the external crossflow can, under certain circumstances, increase the discharge coefficient. This is contrary to most situations, where the external flow results in a decrease in discharge coefficient. The large-scale testing reported helps to explain this phenomenon through an increased understanding of the interaction between the emerging coolant jet and the free-stream flow. The crossover phenomenon came to light during an investigation into the influence of external crossflow on the discharge coefficients of nozzle guide vane film cooling holes. These experiments were performed in the Cold Heat Transfer Tunnel (CHTT), an annular blowdown cascade of film cooled vanes that models the three-dimensional external flow patterns found in modern aero-engines. (Rowbury et al., 1997, 1998). The variation in static pressure around the exit of film cooling holes under different flow conditions was investigated in the large-scale tests. The study centered on three holes whose geometries were based on those found in the leading edge region of the CHTT vanes, as the crossover phenomenon was witnessed for these rows during the initial testing. The experiments were carried out in a low-speed wind tunnel, with the tunnel free-stream flow velocity set to match the free-stream Reynolds number (based on the local radius of curvature) and the “coolant” flow velocity set to replicate the engine coolant-to-free-stream momentum flux ratio. It was found that the apparent enhancement of film cooling hole discharge coefficients with external crossflow was caused by a reduction in the static pressure around the hole exit, associated with the local acceleration of the free-stream around the emerging coolant jet. When these measured static pressures (rather than the free-stream static pressure) were used to calculate the discharge coefficient, the crossover effect was absent. The improved understanding of the crossover phenomenon and coolant-to-free-stream interactions that has been gained will be valuable in aiding the formulation of predictive discharge coefficient schemes.


1998 ◽  
Vol 120 (3) ◽  
pp. 557-563 ◽  
Author(s):  
M. Gritsch ◽  
A. Schulz ◽  
S. Wittig

This paper presents the discharge coefficients of three film-cooling hole geometries tested over a wide range of flow conditions. The hole geometries include a cylindrical hole and two holes with a diffuser-shaped exit portion (i.e., a fan-shaped and a laidback fan-shaped hole). The flow conditions considered were the crossflow Mach number at the hole entrance side (up to 0.6), the crossflow Mach number at the hole exit side (up to 1.2), and the pressure ratio across the hole (up to 2). The results show that the discharge coefficient for all geometries tested strongly depends on the flow conditions (crossflows at hole inlet and exit, and pressure ratio). The discharge coefficient of both expanded holes was found to be higher than of the cylindrical hole, particularly at low pressure ratios and with a hole entrance side crossflow applied. The effect of the additional layback on the discharge coefficient is negligible.


1983 ◽  
Vol 105 (2) ◽  
pp. 243-248 ◽  
Author(s):  
N. Hay ◽  
D. Lampard ◽  
S. Benmansour

The strongest flow parameter governing the film cooling effectiveness provided by a row of holes is the blowing rate. Precise setting of the blowing rate at the design stage requires accurate data for the discharge coefficient of the holes. The effects of crossflow on the discharge coefficient have received scant attention in published work to date. In the present work, the discharge coefficient of single rows of holes has been measured in a specially constructed isothermal rig over a wide range of geometric and flow conditions. Mainstream and coolant Mach numbers have been varied independently over the range 0 to 0.4 for pressure ratios in the range 0 to 2. Cooling hole length to diameter ratios were varied between 2 and 6, and inclinations of 30, 60, and 90 deg were used. The results show that the influence of crossflow is strong and complex, particularly with regard to that on the coolant side. A large range of data is presented sufficient to permit the discharge coefficient to be inferred for many cases of practical importance. Suggestions are also made for a promising theoretical approach to this problem.


Author(s):  
D. A. Rowbury ◽  
M. L. G. Oldfield ◽  
G. D. Lock

This paper discusses large-scale, low-speed experiments that explain unexpected flow-interaction phenomena witnessed during annular cascade studies into the influence of external crossflow on film cooling hole discharge coefficients. More specifically, the experiments throw light on the crossover phenomenon, where the presence of the external crossflow can, under certain circumstances, increase the discharge coefficient. This is contrary to most situations, where the external flow results in a decrease in discharge coefficient. The large-scale testing reported helps to explain this phenomena through an increased understanding of the interaction between the emerging coolant jet and the freestream flow. The crossover phenomenon came to light during an investigation into the influence of external crossflow on the discharge coefficients of nozzle guide vane film cooling holes. These experiments were performed in the Cold Heat Transfer Tunnel (CHTT), an annular blowdown cascade of film cooled vanes which models the three-dimensional external flow patterns found in modern aero-engines. (Rowbury et al., 1997 and 1998). The variation in static pressure around the exit of film cooling holes under different flow conditions was investigated in the large-scale tests. The study centred on three holes whose geometries were based on those found in the leading edge region of the CHTT vanes, as the crossover phenomenon was witnessed for these rows during the initial testing. The experiments were carried out in a low speed wind tunnel, with the tunnel freestream flow velocity set to match the freestream Reynolds number (as based on the local radius of curvature) and the ‘coolant’ flow velocity set to replicate the engine coolant-to-freestream momentum flux ratio. It was found that the apparent enhancement of film cooling hole discharge coefficients with external crossflow was caused by a reduction in the static pressure around the hole exit, associated with the local acceleration of the freestream around the emerging coolant jet. When these measured static pressures (rather than the freestream static pressure) were used to calculate the discharge coefficient, the crossover effect was absent. The improved understanding of the crossover phenomenon and coolant-to-freestream interactions that has been gained will be valuable in aiding the formulation of predictive discharge coefficient schemes.


2000 ◽  
Vol 123 (2) ◽  
pp. 258-265 ◽  
Author(s):  
D. A. Rowbury ◽  
M. L. G. Oldfield ◽  
G. D. Lock

An empirical means of predicting the discharge coefficients of film cooling holes in an operating engine has been developed. The method quantifies the influence of the major dimensionless parameters, namely hole geometry, pressure ratio across the hole, coolant Reynolds number, and the freestream Mach number. The method utilizes discharge coefficient data measured on both a first-stage high-pressure nozzle guide vane from a modern aero-engine and a scale (1.4 times) replica of the vane. The vane has over 300 film cooling holes, arranged in 14 rows. Data was collected for both vanes in the absence of external flow. These noncrossflow experiments were conducted in a pressurized vessel in order to cover the wide range of pressure ratios and coolant Reynolds numbers found in the engine. Regrettably, the proprietary nature of the data collected on the engine vane prevents its publication, although its input to the derived correlation is discussed. Experiments were also conducted using the replica vanes in an annular blowdown cascade which models the external flow patterns found in the engine. The coolant system used a heavy foreign gas (SF6 /Ar mixture) at ambient temperatures which allowed the coolant-to-mainstream density ratio and blowing parameters to be matched to engine values. These experiments matched the mainstream Reynolds and Mach numbers and the coolant Mach number to engine values, but the coolant Reynolds number was not engine representative (Rowbury, D. A., Oldfield, M. L. G., and Lock, G. D., 1997, “Engine-Representative Discharge Coefficients Measured in an Annular Nozzle Guide Vane Cascade,” ASME Paper No. 97-GT-99, International Gas Turbine and Aero-Engine Congress & Exhibition, Orlando, Florida, June 1997; Rowbury, D. A., Oldfield, M. L. G., Lock, G. D., and Dancer, S. N., 1998, “Scaling of Film Cooling Discharge Coefficient Measurements to Engine Conditions,” ASME Paper No. 98-GT-79, International Gas Turbine and Aero-Engine Congress & Exhibition, Stockholm, Sweden, June 1998). A correlation for discharge coefficients in the absence of external crossflow has been derived from this data and other published data. An additive loss coefficient method is subsequently applied to the cascade data in order to assess the effect of the external crossflow. The correlation is used successfully to reconstruct the experimental data. It is further validated by successfully predicting data published by other researchers. The work presented is of considerable value to gas turbine design engineers as it provides an improved means of predicting the discharge coefficients of engine film cooling holes.


1994 ◽  
Vol 116 (1) ◽  
pp. 92-96 ◽  
Author(s):  
N. Hay ◽  
S. E. Henshall ◽  
A. Manning

In the cooling passages of gas turbine blades, branches are often angled to the direction of the internal flow. This is particularly the case with film cooling holes. Accurate knowledge of the discharge coefficient of such holes at the design stage is vital so that the holes are correctly sized, thus avoiding wastage of coolant and the formation of hot spots on the blade. This paper describes an experimental investigation to determine the discharge coefficient of 30 deg inclined holes with various degrees of inlet radiusing and with the axis of the hole at various orientation angles to the direction of the flow. Results are given for nominal main flow Mach numbers of 0, 0.15, and 0.3. The effects of radiusing, orientation, and crossflow Mach number are quantified in the paper, the general trends are described, and the criteria for optimum performance are identified.


2018 ◽  
Vol 140 (7) ◽  
Author(s):  
Daniel Feseker ◽  
Mats Kinell ◽  
Matthias Neef

The ability to understand and predict the pressure losses of orifices is important in order to improve the air flow within the secondary air system. This experimental study investigates the behavior of the discharge coefficient for circular orifices with inlet cross flow which is a common flow case in gas turbines. Examples of this are at the inlet of a film cooling hole or the feeding of air to a blade through an orifice in a rotor disk. Measurements were conducted for a total number of 38 orifices, covering a wide range of length-to-diameter ratios, including short and long orifices with varying inlet geometries. Up to five different chamfer-to-diameter and radius-to-diameter ratios were tested per orifice length. Furthermore, the static pressure ratio across the orifice was varied between 1.05 and 1.6 for all examined orifices. The results of this comprehensive investigation demonstrate the beneficial influence of rounded inlet geometries and the ability to decrease pressure losses, which is especially true for higher cross flow ratios where the reduction of the pressure loss in comparison to sharp-edged holes can be as high as 54%. With some exceptions, the chamfered orifices show a similar behavior as the rounded ones but with generally lower discharge coefficients. Nevertheless, a chamfered inlet yields lower pressure losses than a sharp-edged inlet. The obtained experimental data were used to develop two correlations for the discharge coefficient as a function of geometrical as well as flow properties.


Author(s):  
N. Meah ◽  
M. Hunt ◽  
R. Evans ◽  
T. Racz ◽  
J. Verdicchio ◽  
...  

This paper describes the application of geometry morphing, integrated with meshing and flow simulation, to the topological optimisation of gas turbine film cooling holes. Using a Genetic Algorithm to manage the digitally represented geometry a wide range of novel cooling hole shapes can be generated and useful improvements in film cooling effectiveness are observed. The simulations suggest that modified vortical flow structures are responsible for improved coolant distribution and coverage at hole exit.


Sign in / Sign up

Export Citation Format

Share Document