Conserving Energy by the Efficient Use of the Industrial Gas Turbine

Author(s):  
D. M. S. Lightbody

The paper covers the basic thermodynamics of the combined cycle concept and illustrates that energy conservation is possible by coupling the Joule and Rankine cycles. It discusses the optimisation of steam conditions and outlines the concept of the unfired combined cycle. “Carnot efficiency” and “pinch points” are shown to be important as is the concept of “specific work” as it relates to the gas turbine in arriving at the best overall cycle efficiencies. The importance of the efficiency characteristic of the steam turbine is emphasised and it is shown that this characteristic will determine the overall cycle efficiency. It is suggested that steam turbine manufacturers should design and develop steam turbines to match the advanced gas turbines available to-day and so enchance the overall efficiency which can presently be obtained from to-day’s combined cycle. Market forces will tend to bring this about as evidenced by the growing interest being shown in this concept both in the UK and Europe.

Author(s):  
P. J. Dechamps

The last decade has seen remarkable improvements in industrial gas turbine size and performances. There is no doubt that the coming years are holding the promises of even more progress in these fields. As a consequence, the fuel utilization achieved by combined cycle power plants has been steadily increased. This is however also because of the developments in the heat recovery technology. Advances on the gas turbine side justify the development of new combined cycle schemes, with more advanced heat recovery capabilities. Hence, the system performance is spiralling upwards. In this paper, we look at some of the heat recovery possibilities with the newly available gas turbine engines, characterized by a high exhaust temperature, a high specific work, and the integration of some gas turbine cooling with the boiler. The schemes range from classical dual pressure systems, to triple pressure systems with reheat in supercritical steam conditions. For each system, an optimum set of variables (steam pressures, etc) is proposed. The effect of some changes on the steam cycle parameters, like increasing the steam temperatures above 570°C are also considered. Emphasis is also put on the influence of some special features or arrangements of the heat recovery steam generators, not only from a thermodynamic point of view.


Author(s):  
Christian Vandervort ◽  
David Leach ◽  
David Walker ◽  
Jerry Sasser

Abstract The power generation industry is facing unprecedented challenges. High fuel costs and increased penetration of renewable power have resulted in greater demand for high efficiency and operational flexibility. Imperatives to reduce carbon footprint place an even higher premium on efficiency. Power producers are seeking highly efficient, reliable, and operationally flexible solutions that provide long-term profitability in a volatile environment. New generation must also be cost-effective to ensure affordability for both domestic and industrial consumers. Gas turbine combined cycle power plants meet these requirements by providing reliable, dispatchable generation with a low cost of electricity, reduced environmental impact, and broad operational flexibility. Start times for large, industrial gas turbine combined cycles are less than 30 minutes from turning gear to full load, with ramp rates from 60 to 88 MW/minute. GE introduced the 7/9HA industrial gas turbine product portfolio in 2014 in response to these demands. These air-cooled, H-class gas turbines (7/9HA) are engineered to achieve greater than 63% net combined cycle efficiency while delivering operational flexibility through deep, emission-compliant turndown and high ramp rates. The largest of these gas turbines, the 9HA.02, is designed to exceed 64% combined cycle efficiency (net, ISO) in a 1×1, single-shaft (SS) configuration. As of December 2018, a total of 32 7/9HA power plants have achieved COD (Commercial Operation Date) while accumulating over 220,000 hours of operation. These plants operate across a variety of demand profiles including base load and load following (intermediate) service. Fleet leaders for both the 7HA and 9HA have exceeded 12,000 hours of operation, with multiple units over 8,000 hours. This paper will address four topics relating to the HA platform: 1) gas turbine product technology, 2) gas turbine validation, 3) integrated power plant commissioning and operating experience, and 4) lessons learned and fleet reliability.


Author(s):  
Meherwan P. Boyce

The performance analysis of the new generation of Gas Turbines in combined cycle operation is complex and presents new problems, which have to be addressed. The new units operate at very high turbine firing temperatures. Thus variation in this firing temperature significantly affects the performance and life of the components in the hot section of the turbine. The compressor pressure ratio is high which leads to a very narrow operation margin, thus making the turbine very susceptible to compressor fouling. The turbines are also very sensitive to backpressure exerted on them by the heat recovery steam generators. The pressure drop through the air filter also results in major deterioration of the performance of the turbine. The performance of the combined cycle is also dependent on the steam turbine performance. The steam turbine is dependent on the pressure, temperature, and flow generated in the heat recovery steam generator, which in turn is dependent on the turbine firing temperature, and the air mass flow through the gas turbine. It is obvious that the entire system is very intertwined and that deterioration of one component will lead to off-design operation of other components, which in most cases leads to overall drop in cycle efficiency. Thus, determining component performance and efficiency is the key to determining overall cycle efficiency. Thermodynamic modeling of the plant with individual component analysis is not only extremely important in optimizing the overall performance of the plant but in also determining life cycle considerations.


1998 ◽  
Vol 120 (2) ◽  
pp. 350-357 ◽  
Author(s):  
P. J. Dechamps

The last decade has seen remarkable improvements in industrial gas turbine size and performances. There is no doubt that the coming years are holding the promise of even more progress in these fields. As a consequence, the fuel utilization achieved by combined cycle power plants has been steadily increased. This is, however, also because of the developments in the heat recovery technology. Advances on the gas turbine side justify the development of new combined cycle schemes, with more advanced heat recovery capabilities. Hence, the system performance is spiraling upward. In this paper, we look at some of the heat recovery possibilities with the newly available gas turbine engines, characterized by a high exhaust temperature, a high specific work, and the integration of some gas turbine cooling with the boiler. The schemes range from classical dual pressure systems, to triple pressure systems with reheat in supercritical steam conditions. For each system, an optimum set of variables (steam pressures, etc.) is proposed. The effect of some changes on the steam cycle parameters, like increasing the steam temperatures above 570°C are also considered. Emphasis is also put on the influence of some special features or arrangements of the heat recovery steam generators, not only from a thermodynamic point of view.


2015 ◽  
Vol 5 (2) ◽  
pp. 89
Author(s):  
Munzer S. Y. Ebaid ◽  
Qusai Z. Al-hamdan

<p class="1Body">Several modifications have been made to the simple gas turbine cycle in order to increase its thermal efficiency but within the thermal and mechanical stress constrain, the efficiency still ranges between 38 and 42%. The concept of using combined cycle power or CPP plant would be more attractive in hot countries than the combined heat and power or CHP plant. The current work deals with the performance of different configurations of the gas turbine engine operating as a part of the combined cycle power plant. The results showed that the maximum CPP cycle efficiency would be at a point for which the gas turbine cycle would have neither its maximum efficiency nor its maximum specific work output. It has been shown that supplementary heating or gas turbine reheating would decrease the CPP cycle efficiency; hence, it could only be justified at low gas turbine inlet temperatures. Also it has been shown that although gas turbine intercooling would enhance the performance of the gas turbine cycle, it would have only a slight effect on the CPP cycle performance.</p>


Author(s):  
T. L. Ragland

After industrial gas turbines have been in production for some amount of time, there is often an opportunity to improve or “uprate” the engine’s output power or cycle efficiency or both. In most cases, the manufacturer would like to provide these uprates without compromising the proven reliability and durability of the product. Further, the manufacturer would like the development of this “Uprate” to be low cost, low risk and result in an improvement in “customer value” over that of the original design. This paper describes several options available for enhancing the performance of an existing industrial gas turbine engine and discusses the implications for each option. Advantages and disadvantages of each option are given along with considerations that should be taken into account in selecting one option over another. Specific options discussed include dimensional scaling, improving component efficiencies, increasing massflow, compressor zero staging, increasing firing temperature (thermal uprate), adding a recuperator, increasing cycle pressure ratio, and converting to a single shaft design. The implications on output power, cycle efficiency, off-design performance engine life or time between overhaul (TBO), engine cost, development time and cost, auxiliary requirements and product support issues are discussed. Several examples are provided where these options have been successfully implemented in industrial gas turbine engines.


2015 ◽  
Vol 656-657 ◽  
pp. 113-118
Author(s):  
Hsiu Mei Chiu ◽  
Po Chuang Chen ◽  
Yau Pin Chyou ◽  
Ting Wang

The effect of synthetic natural gas (SNG) and mixture of syngas and SNG fed to Natural Gas Combined-Cycle (NGCC) plants is presented in this study via a system-level simulation model. The commercial chemical process simulator, Pro/II®V8.1.1, was used in the study to build the analysis model. The NGCC plant consists of gas turbine (GT), heat recovery steam generator (HRSG) and steam turbine (ST). The study envisages two analyses as the basic and feasibility cases. The former is the benchmark case which is verified by the reference data with the GE 7FB gas turbine. According to vendor’s specification, the typical net plant efficiency of GE 7FB NGCC with two gas turbines to one steam turbine is 57.5% (LHV), and the efficiency is the benchmark in the simulation model built in the study. The latter introduces a feasibility study with actual parameters in Taiwan. The SNG-fed GE 7FB based combined-cycle is evaluated, and the mixture of SNG and syngas is also evaluated to compare the difference of overall performance between the two cases. The maximum ratio of syngas to SNG is 0.14 due to the constraint for keeping the composition of methane at a value of 80 mol%, to meet the minimum requirement of NG in Taiwan. The results show that the efficiency in either case of SNG or mixture of SNG and syngas is slightly lower than the counterpart in the benchmark one. Because the price of natural gas is much higher than that of coal, it results in higher idle capacity of NGCC. The advantage of adopting SNG in Taiwan is that it could increase the capacity factor of combined-cycles in Taiwan. The study shows a possible way to use coal and reduce the CO2emission, since coal provides nearly half of the electricity generation in Taiwan in recent years.


Author(s):  
Satoshi Hada ◽  
Masanori Yuri ◽  
Junichiro Masada ◽  
Eisaku Ito ◽  
Keizo Tsukagoshi

MHI recently developed a 1600°C class J-type gas turbine, utilizing some of the technologies developed in the National Project to promote the development of component technology for the next generation 1700°C class gas turbine. This new frame is expected to achieve higher combined cycle efficiency and will contribute to reduce CO2 emissions. The target combined cycle efficiency of the J type gas turbine will be above 61.5% (gross, ISO standard condition, LHV) and the 1on1 combined cycle output will reach 460MW for 60Hz engine and 670MW for 50Hz engine. This new engine incorporates: 1) A high pressure ratio compressor based on the advanced M501H compressor, which was verified during the M501H development in 1999 and 2001. 2) Steam cooled combustor, which has accumulated extensive experience in the MHI G engine (> 1,356,000 actual operating hours). 3) State-of-art turbine designs developed through the 1700°C gas turbine component technology development program in Japanese National Project for high temperature components. This paper discusses the technical features and the updated status of the J-type gas turbine, especially the operating condition of the J-type gas turbine in the MHI demonstration plant, T-Point. The trial operation of the first M501J gas turbine was started at T-point in February 2011 on schedule, and major milestones of the trial operation have been met. After the trial operation, the first commercial operation has taken place as scheduled under a predominantly Daily-Start-and-Stop (DSS) mode. Afterward, MHI performed the major inspection in October 2011 in order to check the mechanical condition, and confirmed that the hot parts and other parts were in sound condition.


Author(s):  
Markus Feigl ◽  
Geoff Myers ◽  
Stephen R. Thomas ◽  
Raub Smith

This paper describes the concept and benefits of the fuel moisturization system for the GE H System™ steam-cooled industrial gas turbine. The DLN2.5H combustion system and fuel moisturization system are both described, along with the influence of fuel moisture on combustor performance as measured during full-scale, full-pressure rig testing of the DLN2.5H combustion system. The lean, premixed DLN2.5H combustion system was targeted to deliver single-digit NOx and CO emissions from 40% to 100% combined cycle load in both the Frame 7H (60 Hz) and Frame 9H (50 Hz) heavy-duty industrial gas turbines. These machines are also designed to yield a potential combined-cycle efficiency of 60 percent or higher. Fuel moisturization contributes to the attainment of both the NOx and the combined-cycle efficiency performance goals, as discussed in this paper.


Author(s):  
Yasuhiro Yoshida ◽  
Kazunori Yamanaka ◽  
Atsushi Yamashita ◽  
Norihiro Iyanaga ◽  
Takuya Yoshida

In the fast start-up for combined cycle power plants (CCPP), the thermal stresses of the steam turbine rotor are generally controlled by the steam temperatures or flow rates by using gas turbines (GTs), steam turbines, and desuperheaters to avoid exceeding the thermal stress limits. However, this thermal stress sensitivity to steam temperatures and flow rates depends on the start-up sequence due to the relatively large time constants of the heat transfer response in the plant components. In this paper, a coordinated control method of gas turbines and steam turbine is proposed for thermal stress control, which takes into account the large time constants of the heat transfer response. The start-up processes are simulated in order to assess the effect of the coordinated control method. The simulation results of the plant start-ups after several different cool-down times show that the thermal stresses are stably controlled without exceeding the limits. In addition, the steam turbine start-up times are reduced by 22–28% compared with those of the cases where only steam turbine control is applied.


Sign in / Sign up

Export Citation Format

Share Document