Evolution and Future Trend of Large Frame Gas Turbines: A New 1600 Degree C, J Class Gas Turbine

Author(s):  
Satoshi Hada ◽  
Masanori Yuri ◽  
Junichiro Masada ◽  
Eisaku Ito ◽  
Keizo Tsukagoshi

MHI recently developed a 1600°C class J-type gas turbine, utilizing some of the technologies developed in the National Project to promote the development of component technology for the next generation 1700°C class gas turbine. This new frame is expected to achieve higher combined cycle efficiency and will contribute to reduce CO2 emissions. The target combined cycle efficiency of the J type gas turbine will be above 61.5% (gross, ISO standard condition, LHV) and the 1on1 combined cycle output will reach 460MW for 60Hz engine and 670MW for 50Hz engine. This new engine incorporates: 1) A high pressure ratio compressor based on the advanced M501H compressor, which was verified during the M501H development in 1999 and 2001. 2) Steam cooled combustor, which has accumulated extensive experience in the MHI G engine (> 1,356,000 actual operating hours). 3) State-of-art turbine designs developed through the 1700°C gas turbine component technology development program in Japanese National Project for high temperature components. This paper discusses the technical features and the updated status of the J-type gas turbine, especially the operating condition of the J-type gas turbine in the MHI demonstration plant, T-Point. The trial operation of the first M501J gas turbine was started at T-point in February 2011 on schedule, and major milestones of the trial operation have been met. After the trial operation, the first commercial operation has taken place as scheduled under a predominantly Daily-Start-and-Stop (DSS) mode. Afterward, MHI performed the major inspection in October 2011 in order to check the mechanical condition, and confirmed that the hot parts and other parts were in sound condition.

Author(s):  
M. Araki ◽  
J. Masada ◽  
S. Hada ◽  
E. Ito ◽  
K. Tsukagoshi

Mitsubishi Heavy Industries, Ltd. (MHI) developed a 1100°C class D-type gas turbine in the 1980s and constructed the world’s first successful large-scale combined cycle power plant. Since then, MHI has developed the F and G-type gas turbines with higher turbine inlet temperature and has delivered these units worldwide accumulating successful commercial operations. MHI is currently participating in a Japanese National Project to promote the development of component technology for the next generation 1700°C class gas turbine. MHI recently developed a 1600°C class J-type gas turbine utilizing some of the technologies developed in the National Project. This paper discusses the history and evolution of MHI large frame gas turbine for power generation and the 1600°C class J-type gas turbine update, including the engine specification, verification and trial operation status.


Author(s):  
Meherwan P. Boyce

The performance analysis of the new generation of Gas Turbines in combined cycle operation is complex and presents new problems, which have to be addressed. The new units operate at very high turbine firing temperatures. Thus variation in this firing temperature significantly affects the performance and life of the components in the hot section of the turbine. The compressor pressure ratio is high which leads to a very narrow operation margin, thus making the turbine very susceptible to compressor fouling. The turbines are also very sensitive to backpressure exerted on them by the heat recovery steam generators. The pressure drop through the air filter also results in major deterioration of the performance of the turbine. The performance of the combined cycle is also dependent on the steam turbine performance. The steam turbine is dependent on the pressure, temperature, and flow generated in the heat recovery steam generator, which in turn is dependent on the turbine firing temperature, and the air mass flow through the gas turbine. It is obvious that the entire system is very intertwined and that deterioration of one component will lead to off-design operation of other components, which in most cases leads to overall drop in cycle efficiency. Thus, determining component performance and efficiency is the key to determining overall cycle efficiency. Thermodynamic modeling of the plant with individual component analysis is not only extremely important in optimizing the overall performance of the plant but in also determining life cycle considerations.


Author(s):  
T. L. Ragland

After industrial gas turbines have been in production for some amount of time, there is often an opportunity to improve or “uprate” the engine’s output power or cycle efficiency or both. In most cases, the manufacturer would like to provide these uprates without compromising the proven reliability and durability of the product. Further, the manufacturer would like the development of this “Uprate” to be low cost, low risk and result in an improvement in “customer value” over that of the original design. This paper describes several options available for enhancing the performance of an existing industrial gas turbine engine and discusses the implications for each option. Advantages and disadvantages of each option are given along with considerations that should be taken into account in selecting one option over another. Specific options discussed include dimensional scaling, improving component efficiencies, increasing massflow, compressor zero staging, increasing firing temperature (thermal uprate), adding a recuperator, increasing cycle pressure ratio, and converting to a single shaft design. The implications on output power, cycle efficiency, off-design performance engine life or time between overhaul (TBO), engine cost, development time and cost, auxiliary requirements and product support issues are discussed. Several examples are provided where these options have been successfully implemented in industrial gas turbine engines.


Author(s):  
Ivan G. Rice

Interest in the reheat-gas turbine (RHGT) as a way to improve combined-cycle efficiency is gaining momentum. Compression intercooling makes it possible to readily increase the reheat-gas-turbine cycle-pressure ratio and at the same time increase gas-turbine output; but at the expense of some combined-cycle efficiency and mechanical complexity. This paper presents a thermodynamic analysis of the intercooled cycle and pinpoints the proper intercooling pressure range for minimum combined-cycle-efficiency loss. At the end of the paper two-intercooled reheat-gas-turbine configurations are presented.


1982 ◽  
Vol 104 (1) ◽  
pp. 9-22 ◽  
Author(s):  
I. G. Rice

The reheat (RH) pressure can be appreciably increased by applying steam cooling to the gas-generator (GG) turbine blading which in turn allows a higher RH firing temperature for a fixed exhaust temperature. These factors increase gas turbine output and raise combined-cycle efficiency. The GG turbine blading will approach “uncooled expansion efficiency”. Eliminating cooling air increases the gas turbine RH pressure by 10.6 percent. When steam is used (injected) as the blade coolant, additional GG work is also developed which further increases the RH pressure by another 12.0 percent to yield a total increase of approximately 22.6 percent. The 38-cycle pressure ratio 2400° F (1316° C) TIT GG studied produces a respectable 6.5 power turbine expansion ratio. The higher pressure also noticeably reduces the physical size of the RH combustor. This paper presents an analysis of the RH pressure rise when applying steam to blade cooling.


1983 ◽  
Vol 105 (4) ◽  
pp. 844-850 ◽  
Author(s):  
I. G. Rice

High-cycle pressure-ratio (38–42) gas turbines being developed for future aircraft and, in turn, industrial applications impose more critical disk and casing cooling and thermal-expansion problems. Additional attention, therefore, is being focused on cooling and the proper selection of materials. Associated blade-tip clearance control of the high-pressure compressor and high-temperature turbine is critical for high performance. This paper relates to the use of extracted steam from a steam turbine as a coolant in a combined cycle to enhance material selection and to control expansion in such a manner that the cooling process increases combined-cycle efficiency, gas turbine output, and steam turbine output.


Author(s):  
R. Yadav

The increase in efficiency of combined cycle has mainly been caused by the improvements in gas turbine cycle efficiency. With the increase in firing temperature the exhaust temperature is substantially high around 873 K for moderate compressor pressure ratio, which has positive influence on steam cycle efficiency. Minimizing the irreversibility within the heat recovery steam generator HRSG and choosing proper steam cycle configuration with optimized steam parameters improve the steam cycle efficiency and thus in turn the combined cycle efficiency. In this paper, LM9001H gas turbine, a state of art technology turbine with modified compressor pressure ratio has been chosen as a topping cycle. Various bottoming cycles alternatives (sub-critical) coupled with LM9001H topping cycle with and without recuperation such as dual and triple pressure steam cycles with and without reheat have been chosen to predict the performance of combined cycle.


2005 ◽  
Vol 127 (2) ◽  
pp. 369-374 ◽  
Author(s):  
Y. Fukuizumi ◽  
J. Masada ◽  
V. Kallianpur ◽  
Y. Iwasaki

Mitsubishi completed design development and verification load testing of a steam-cooled M501H gas turbine at a combined cycle power plant at Takasago, Japan in 2001. Several advanced technologies were specifically developed in addition to the steam-cooled components consisting of the combustor, turbine blades, vanes, and the rotor. Some of the other key technologies consisted of an advanced compressor with a pressure ratio of 25:1, active clearance control, and advanced seal technology. Prior to the M501H, Mitsubishi introduced cooling-steam in “G series” gas turbines in 1997 to cool combustor liners. Recently, some of the advanced design technologies from the M501H gas turbine were applied to the G series gas turbine resulting in significant improvement in output and thermal efficiency. A noteworthy aspect of the technology transfer is that the upgraded G series M701G2 gas turbine has an almost equivalent output and thermal efficiency as H class gas turbines while continuing to rely on conventional air cooling of turbine blades and vanes, and time-proven materials from industrial gas turbine experience. In this paper we describe the key design features of the M701G2 gas turbine that make this possible such as the advanced 21:1 compressor with 14 stages, an advanced premix DLN combustor, etc., as well as shop load test results that were completed in 2002 at Mitsubishi’s in-house facility.


1997 ◽  
Vol 119 (2) ◽  
pp. 298-304 ◽  
Author(s):  
A. R. Smith ◽  
J. Klosek ◽  
D. W. Woodward

The commercialization of Integrated Gasification Combined Cycle (IGCC) Power has been aided by concepts involving the integration of a cryogenic air separation unit (ASU) with the gas turbine combined-cycle module. Other processes, such as coal-based ironmaking and combined power/industrial gas production facilities, can also benefit from the integration. It is known and now widely accepted that an ASU designed for “elevated pressure” service and optimally integrated with the gas turbine can increase overall IGCC power output, increase overall efficiency, and decrease the net cost of power generation when compared to nonintegrated facilities employing low-pressure ASUs. The specific gas turbine, gasification technology, NOx emission specification, and other site specific factors determine the optimal degree of compressed air and nitrogen stream integration. Continuing advancements in both air separation and gas turbine technologies offer new integration opportunities to improve performance and reduce costs. This paper reviews basic integration principles and describes next-generation concepts based on advanced high pressure ratio gas turbines, Humid Air Turbine (HAT) cycles and integration of compression heat and refrigeration sources from the ASU. Operability issues associated with integration are reviewed and control measures are described for the safe, efficient, and reliable operation of these facilities.


Author(s):  
Geoff Myers ◽  
Dan Tegel ◽  
Markus Feigl ◽  
Fred Setzer ◽  
William Bechtel ◽  
...  

The lean, premixed DLN2.5H combustion system was designed to deliver low NOx emissions from 50% to 100% load in both the Frame 7H (60 Hz) and Frame 9H (50 Hz) heavy-duty industrial gas turbines. The H machines employ steam cooling in the gas turbine, a 23:1 pressure ratio, and are fired at 1440 C (2600 F) to deliver over-all thermal efficiency for the combined-cycle system near 60%. The DLN2.5H combustor is a modular can-type design, with 14 identical chambers used on the 9H machine, and 12 used on the smaller 7H. On a 9H combined-cycle power plant, both the gas turbine and steam turbine are fired using the 14-chamber DLN2.5H combustion system. An extensive full-scale, full-pressure rig test program developed the fuel-staged dry, low emissions combustion system over a period of more than five years. Rig testing required test stand inlet conditions of over 50 kg/s at 500 C and 28 bar, while firing at up to 1440 C, to simulate combustor operation at base load. The combustion test rig simulated gas path geometry from the discharge of the annular tri-passage diffuser through the can-type combustion liner and transition piece, to the inlet of the first stage turbine nozzle. The present paper describes the combustion system, and reports emissions performance and operability results over the gas turbine load and ambient temperature operating range, as measured during the rig test program.


Sign in / Sign up

Export Citation Format

Share Document