Frequency Response of Primary Resonance of Double Wall Carbon Nanotube Under Electrostatic Actuation

Author(s):  
Dumitru I. Caruntu ◽  
Ezequiel Juarez

This paper deals with electrostatically actuated Double Walled Carbon Nanotubes (DWCNT) cantilever resonators. DWCNTs are modeled as Euler-Bernoulli cantilever beams. Electrostatic, damping, and van der Waals, forces act on the outer tube of the DWCNT, while only van der Waals force acts on the inner tube. A soft AC voltage provides the electrostatic actuation. Van der Waals forces are present between the carbon nanotubes, coupling the deflections of the tubes. The nonlinearities in the system are given by the electrostatic and van der Waals forces. The DWCNT undergoes nonlinear parametric dynamics. The Method of Multiple Scales (MMS) is employed to investigate the system under soft excitations and/or weak nonlinearities. A modal coordinate transformation, in which only the linear term of the van der Waals force are considered, and the Harmonic Balance Method (HBM), are used to solve the zero-order problem. Then the frequency-amplitude response is found in the case of primary resonance. The expected nonlinear dynamic behavior is important to improve DWCNT resonator sensitivity in the application of mass sensing.

Author(s):  
Dumitru I. Caruntu ◽  
Ezequiel Juarez

This paper investigates electrostatically actuated Double Walled Carbon Nanotubes (DWCNT) cantilever biosensors using the Method of Multiple Scales (MMS) and the Harmonic Balance Method (HBM). Forces acting on the outer tube of the DWCNT are electrostatic, damping, and van der Waals, while only van der Waals acts on the inner tube. The electrostatic actuation is provided by a soft AC voltage. Van der Waals forces are present between the carbon nanotubes, coupling the deflections of the tubes; herein, for modal coordinate transformation, only the linear term of the van der Waals force will be considered. The nonlinearity of the motion is produced by the electrostatic and van der Waals forces. The DWCNT undergoes nonlinear parametric dynamics. MMS is employed to investigate the system under soft excitations and/or weak nonlinearities. The frequency-amplitude response is found in the case of primary resonance. DWCNTs are modelled after the Euler-Bernoulli cantilever beam. The expected nonlinear dynamic behavior is important to improve DWCNT resonator sensitivity in the application of mass sensing.


Author(s):  
Dumitru I. Caruntu ◽  
Ezequiel Juarez

Abstract This paper deals with the frequency-amplitude response of primary resonance of electrostatically actuated Double-Walled Carbon Nanotubes (DWCNT) and Single-Walled Carbon Nanotubes (SWCNT) cantilever resonators. Their responses are compared. Both the DWCNT and SWCNT are modeled as Euler-Bernoulli cantilever beams. Electrostatic and damping forces are applied on both types of resonators. An AC voltage provides a soft electrostatic actuation. For the DWCNT, intertube van der Waals forces are present between the carbon nanotubes, coupling the deflections of the tubes and acting as a nonlinear spring between the two carbon nanotubes. Electrostatic (for SWCNT and DWCNT) and intertube van der Waals (for DWCNT) forces are nonlinear. Both resonators undergo nonlinear parametric excitation. The Method of Multiple Scales (MMS) is used to investigate the systems under soft excitations and weak nonlinearities. A 2-Term Reduced-Order-Model (ROM) is numerically solved for stability analysis using AUTO-07P, a continuation and bifurcation software. The coaxial vibrations of DWCNT are considered in this work, in order to draw comparisons between DWCNT and SWCNT. Effects of damping and voltage of the frequency-amplitude response are reported.


Author(s):  
Dumitru I. Caruntu ◽  
Ezequiel Juarez

This paper deals with electrostatically actuated Double Walled Carbon Nanotubes (DWCNT) cantilevered resonators. The governing equations for the motion of the DWCNT are derived through Euler-Bernoulli beam model assumptions that account for inertial and viscoelastic effects. The DWCNT is a specific type of multi-walled carbon nanotube (MWCNT) that is comprised of two coaxially concentric carbon nanotubes. Electrostatic, damping, and intertube van der Waals forces act on the outer tube of the DWCNT, while only intertube van der Waals force acts on the inner tube. A soft AC voltage provides the electrostatic actuation. The nonlinear behavior and phenomena in the system are provided by the electrostatic and intertube van der Waals forces. The DWCNT is subjected to nonlinear parametric dynamics. The Method of Multiple Scales (MMS) is employed to investigate the system under soft excitations and/or weak nonlinearities. The frequency-amplitude response is found in the case of parametric resonance. The resulting nonlinear dynamic behavior is important to improve DWCNT resonator sensitivity in the application of mass sensing.


Author(s):  
Dumitru I. Caruntu ◽  
Cone S. Salinas Trevino

This paper deals with electrostatically actuated Carbon NanoTubes (CNT) cantilevers for bio-sensing applications. There are three kinds of forces acting on the CNT cantilever: electrostatic, elastostatic, and van der Waals. The van der Waals forces are significant for values of 50 nm or lower of the gap between the CNT and the ground plate. As both forces electrostatic and van der Waals are nonlinear, and the CNT electrostatic actuation is given by AC voltage, the CNT dynamics is nonlinear parametric. The method of multiple scales is used to investigate the system under soft excitations and/or weakly nonlinearities. The frequency-amplitude and frequency-phase behavior are found in the case of primary resonance. The CNT bio-sensor is to be used for mass detection applications.


Author(s):  
Dumitru I. Caruntu ◽  
Ezequiel Juarez

Abstract This paper deals with electrostatically actuated Double-Walled Carbon Nanotubes (DWCNT) and Single-Walled Carbon Nanotubes (SWCNT) cantilever resonators. Frequency response of parametric resonance is investigated. Euler-Bernoulli cantilever beam model is used for both DWCNT and SWCNT. Electrostatic and viscous damping forces are applied on both types of resonators, DWCNT and SWCNT. In this investigation, soft AC voltage excitation is assumed. For the DWCNT, an intertube van der Waals force is present between the two concentric carbon nanotubes (CNTs), coupling their motion and acting as a nonlinear spring. The nonlinearities in the vibration are provided by the electrostatic (both SWCNT and DWCNT) and intertube van der Waals forces (DWCNT). The Method of Multiple Scales (MMS) is a perturbation method that provides uniformly valid approximations for weakly nonlinear systems. A Reduced-Order-Model (ROM) is developed and numerically solved using AUTO-07P (bifurcation and continuation software). Since large tip deflections are investigated in this paper, only coaxial vibration of the DWCNT is considered. Parametric resonance is investigated, as well as the influences of damping and voltage. Lastly, the effect of intertube van der Waals force on the bifurcation and stability of the DWCNT is reported.


Author(s):  
Dumitru I. Caruntu ◽  
Reynaldo Oyervides

This investigation deals with M/NEMS circular plates under electrostatic actuation. Such structures can be used as resonator sensors for medicine and biology applications such as virus, bacteria or DNA detection. The system consists of a clamped circular plate over a ground. The actuation of the plate is done through an AC voltage whose frequency is near half natural frequency of the plate. This produces a primary resonance to be used afterwards for sensing purposes. It is showed that a saddle-node bifurcation occurs. The effects of damping, voltage, Casimir, and van der Waals forces are predicted.


Author(s):  
Dumitru I. Caruntu ◽  
Le Luo

This paper investigates electrostatically actuated Carbon Nano-Tubes (CNT) cantilevers biosensors using the Reduced Order Model (ROM) method. Forces acting on the CNT are electrostatic, damping, and van der Waals. The electrostatic actuation is given by soft AC voltage. Van der Waals forces are significant for gaps between the CNT and a ground plate lower than 100 nm. Both forces electrostatic and van der Waals are nonlinear. CNT undergoes nonlinear parametric dynamics. ROM is used to investigate the system under soft excitations and/or weak nonlinearities. The frequency-amplitude response is found in the case of primary resonance and compared to the Method of Multiple Scales (MMS). The CNT biosensor is to be used for mass detection applications.


Author(s):  
Dumitru I. Caruntu ◽  
Iris Alvarado

This paper deals with electrostatically actuated micro and nano-electromechanical (MEMS/NEMS) circular plates. The system under investigation consists of two bodies, a deformable and conductive circular plate placed above a fixed, rigid and conductive ground plate. The deformable circular plate is electrostatically actuated by applying an AC voltage between the two plates. Nonlinear parametric resonance and pull-in occur at certain frequencies and relatively large AC voltage, respectively. Such phenomena are useful for applications such as sensors, actuators, switches, micro-pumps, micro-tweezers, chemical and mass sensing, and micro-mirrors. A mathematical model of clamped circular MEMS/NEMS electrostatically actuated plates has been developed. Since the model is in the micro- and nano-scale, surface forces, van der Waals and/or Casimir, acting on the plate are included. A perturbation method, the Method of Multiple Scales (MMS), is used for investigating the case of weakly nonlinear MEMS/NEMS circular plates. Two time scales, fast and slow, are considered in this work. The amplitude-frequency and phase-frequency response of the plate in the case of primary resonance are obtained and discussed.


Author(s):  
Dumitru I. Caruntu ◽  
Ezequiel Juarez

Abstract In this paper, the Method of Multiple Scales (MMS) is used to investigate the influences of the nonlinear intertube van der Waals coefficient, dimensionless damping, and voltage on the amplitude-frequency response of an electrostatically actuated double-walled carbon nanotube (DWCNT). The forces responsible for the nonlinearities in the vibrational behavior are intertube van der Waals and electrostatic forces. For perturbation, a small viscous damping and soft AC actuation are assumed for numerical simulation. For the first time in literature, forced vibration of the noncoaxial (out-of-phase) case is investigated. In this mode of vibration, the outer and inner carbon nanotubes move at ultra-high frequency in opposite direction, i.e., negative amplitude ratio. The DWCNT structure is modelled as a cantilever beam with Euler-Bernoulli beam assumptions since the DWCNT is assumed to have a high length-diameter ratio. The results shown assume steady-state solutions in the second-order MMS solution. The importance of the results in this paper are the effect of the strong nonlinearity of the van der Waals coefficient, damping, and voltage on the the DWCNT vibration.


Author(s):  
Ezequiel Juarez ◽  
Dumitru I. Caruntu

In this paper, the Reduced Order Method (ROM) and the Method of Multiple Scales (MMS) are used to investigate the influences of dimensionless damping and voltage parameters on the amplitude-frequency response of an electrostatically actuated double-walled carbon nanotube (DWCNT). The forces responsible for the nonlinearities in the vibrational behavior are intertube van der Waals and electrostatic forces. Soft AC excitation and small viscous damping forces are assumed. Herein, the coaxial case is investigated. In this mode of vibration, the outer and inner carbon nanotubes move synchronously (in-phase) with the same maximum tip deflection. The DWCNT structure is modelled as a cantilever beam with Euler-Bernoulli beam assumptions since the DWCNT is characterized with high length-diameter ratio. The results shown assume steady-state solutions in the first-order MMS solution. The analytical approximate solutions provided by MMS are validated numerically by two-term (2T) Time Reponses and AUTO-07P. The two methods in this paper are found to be in excellent agreement at lower amplitudes. Additionally, the two methods are assessed for their advantages and limitations. The importance of the results in this paper are the effect of damping and voltage on the stability of the DWCNT vibration.


Sign in / Sign up

Export Citation Format

Share Document