Design of the 6C Heavy-Duty Gas Turbine

Author(s):  
David Harper ◽  
Devin Martin ◽  
Harold Miller ◽  
Robert Grimley ◽  
Fre´de´ric Greiner

The MS6001C gas turbine combines the proven reliability of the General Electric gas turbine family with the advanced technology developed for the FA, FB and H machine designs. The engine configuration is a single shaft bolted rotor, driving a 50 or 60 Hz. generator though a cold end mounted load gear. Rated at 42.3 MW, with a thermal efficiency of 36.3%, the MS6001C will provide greater than a four percent increase in efficiency over the MS6001B. This paper is focused on the design and development of the MS6001C gas turbine, highlighting the commonality between this and other General Electric Power Systems (GEPS) and General Electric Aircraft Engines (GEAE) designs, as well as introducing some new and innovative features. The new high efficiency, 12 stage, axial flow compressor, features a 19:1 pressure ratio with three stages of variable guide vanes. The can annular, six chamber, Dry Low NOx (DLN-2.5H) combustion system is scaled from field proven, low emission technology. The turbine incorporates three stages, two cooled blade rows, and operates at a 1327°C firing temperature. After a thorough factory full speed no load test has been conducted, the first MS6001C engine will be shipped to a customer site in Kemalpasalzmir Turkey, where an instrumented full load test will be conducted to validate the design.

Author(s):  
Y. Kashiwabara ◽  
Y. Katoh ◽  
H. Ishii ◽  
T. Hattori ◽  
Y. Matsuura ◽  
...  

In this paper, the development leading to a 17-stage axial flow compressor (pressure ratio 14.7) for the 25 MW class heavy duty gas turbine H-25 is described. In the course of developing the H-25’s compressor, extensive measurements were carried out on models. Experimental results are compared with predicted values. Aerodynamic experiments covered the measurements of unsteady flows such as rotating stall and surge as well as the steady-state performance of the compressor. Based on the results of these tests, the aerodynamic and mechanical design parameters of the full scale H-25 compressor were finalized on the basis of two model compressors. Detailed measurements of the first unit of the H-25 gas turbine were carried out. Test results on the compressor are presented and show the achievement of the expected design targets.


Author(s):  
F. Carchedi ◽  
G. R. Wood

This paper describes the design and development of a 15-stage axial flow compressor for a −6MW industrial gas turbine. Detailed aspects of the aerodynamic design are presented together with rig test data for the complete characteristic including stage data. Predictions of spanwise flow distributions are compared with measured values for the front stages of the compressor. Variable stagger stator blading is used to control the position of the low speed surge line and the effects of the stagger changes are discussed.


Author(s):  
T. Sugimoto ◽  
K. Ikesawa ◽  
S. Kajita ◽  
W. Karasawa ◽  
T. Kojima ◽  
...  

The M7A-01 gas turbine is a newly developed 6 MW class single-shaft machine. With its high simple-cycle efficiency and high exhaust gas temperature. it is particularly suited for use in electric power generation and co-generation applications. An advanced high efficiency axial-flow compressor, six can-type combustors, and a high inlet temperature turbine has been adopted. This results in a high thermal efficiency of 31.5% at the gas turbine output shaft and a high overall thermal efficiency of co-generation system. In addition, low NOx emissions from the combustors and a long service life permit long-term continuous operation under various environmental limitations. The results of the full load shop test, accelerated cyclic endurance test and extra severity tests verified that the performance, the mechanical characteristics and the emission have satisfied the initial design goals.


1978 ◽  
Author(s):  
B. Becker ◽  
O. von Schwerdtner ◽  
J. Günther

In the course of developing the compressor of a 100-MW gas turbine, extensive measurements took place on a test compressor provided with the four front stages scaled down to 1:4.63. The performance investigations have been supplemented by measurements of flow distribution down- and upstream of the blading, as well as at various intermediate axial positions. The test stand, operating in a closed circuit, allowed for the variation of the Reynolds number by changing the pressure level. The geometry of the inlet casing was variable as well, thus enabling the comparison of results with axial, two- and one-sided inlet flows. In this connection, the vibrational behavior of the rotating blades, besides the aerodynamics of the compressor, have been investigated. In case of the inlet casing with a two-sided inflow, additional flow field analyses have been performed using a model without compressor blading. The theoretical results calculated under the assumption of a rotational-symmetric flow, as well as the measurements at the gas turbine compressor itself, are used for comparison. The gas turbine compressor operating with a mass flow of 483 kg/s at ISO-conditions and a pressure ratio of 10 is running in the highest performance range of single-shaft compressors in operation today.


Author(s):  
Damir Novak ◽  
Michael Loetzerich ◽  
Matthias Boese

A 22-stage axial flow compressor with a pressure ratio 35:1 has been designed, built and successfully tested for a heavy-duty gas turbine application. Advanced technology and aero engine design tools have been used. The compressor has been designed using an “arbitrary” airfoil blading including 3D design features, like leading edge re-camber, lean, sweep and flowpath contouring. The compressor performance and part load behavior have been improved by accurate stage matching based on whole compressor 3D analyses. The new compressor has been tested in a scaled down rig and validated in the Alstom Test Power Plant (ATPP).The compressor met all design objectives and demonstrated excellent performance. This paper describes the aerodynamic design and test results.


1982 ◽  
Vol 104 (4) ◽  
pp. 823-831 ◽  
Author(s):  
F. Carchedi ◽  
G. R. Wood

The paper describes the design and development of a 15 stage axial flow compressor for a 6-MW industrial gas turbine. Detailed aspects of the aerodynamic design are presented together with rig test data for the complete characteristic including stage data. Predictions of spanwise flow distributions are compared with measured values for the front stages of the compressor. Variable stagger stator blading is used to control the position of the low-speed surge line and the effects of the stagger changes are discussed.


Author(s):  
A. T. Sanders ◽  
M. H. Tothill ◽  
G. R. Wood

The paper describes the design of a compact new 1.7MW (2300hp) single shaft industrial gas turbine and package, with high efficiency and exhaust temperature ideal for industrial congeneration applications. These advantages are obtained with a high pressure ratio single stage centrifugal compressor, single high temperature combustor and two-stage axial flow turbine using only one row of cooled blades. The novel design features are described with the associated development testing. A typical installation is also described showing the potential for very high overall thermodynamic efficiency.


Author(s):  
Uyioghosa Igie ◽  
Pericles Pilidis ◽  
Dimitrios Fouflias ◽  
Ken Ramsden ◽  
Paul Lambart

On-line compressor washing for industrial gas turbine application is a promising method of mitigating the effects of compressor fouling degradation; however there are still few studies from actual engine experience that are inconclusive. In some cases the authors attribute this uncertainty as a result of other existing forms of degradation. The experimental approach applied here is one of the first of its kind, employing on-line washing on a compressor cascade and then relating the characteristics to a three-dimensional axial flow compressor. The overall performance of a 226MW engine model for the different cases of a clean, fouled and washed engine is obtained based on the changing compressor behavior. Investigating the effects of fouling on the clean engine exposed to blade roughness of 102μm caused 8.7% reduction in power at design point. This is equivalent, typically to 12 months degradation in fouling conditions. Decreases in mass flow, compressor efficiency, pressure ratio and unattainable design point speed are also observed. An optimistic recovery of 50% of the lost power is obtained after washing which lasts up to 10mins. Similarly, a recovery of all the key parameters is achieved. The study provides an insight into compressor cascade blade washing, which facilitates a reliable estimation of compressor overall efficiency penalties based on well established assumptions. Adopting Howell’s theory as well as constant polytropic efficiency, a general understanding of turbomachinery would judge that 50% of lost power recovered is likely to be the high end of what is achievable for the existing high pressure wash. This investigation highlights the obvious benefits of power recovery with on-line washing and the potential to maintain optimum engine performance with frequent washes. Clearly, the greatest benefits accrue when the washing process is initiated immediately following overhaul.


Author(s):  
Jesuíno Takachi Tomita ◽  
Cleverson Bringhenti ◽  
João Roberto Barbosa ◽  
Vitor Alexandre Carlesse Martins

The design of a small gas turbine in the range of 5 kN thrust / 1.2 MW shaft power is being made in association with industry, aiming at distributed power generation and cogeneration. The gas turbine was constructed and its gas generator is being prepared for development tests. The results will be used for the final specification of the power section. The gas turbine design has been carried out using indigenous software, developed specially to fulfill the requirements of the engines design, as well as the support for validation of research work. The work reported in this paper deals with the design methodology of a 5:1 pressure ratio, 5-stage axial flow compressor with VIGV and a single stage axial flow turbine. These components were designed and their maps synthesized and fed to the gas turbine performance simulation program. The engine performance results were analyzed and verified. The calculated behavior compares with similar engines’, indicating they are qualitatively correct.


Author(s):  
Tadashi Tsuji ◽  
Noboru Yanai ◽  
Kentaro Fujii ◽  
Hitoshi Miyamoto ◽  
Masaharu Watabe ◽  
...  

Today, the need to develop more efficient thermal power systems that emit less greenhouse effect gas has become a paramount importance. In line with this awareness, our research has leapt into such development that the combination of SOFC and Gas Turbine could generate power at extremely high efficiency. In this paper, we would like to present our concept of Inter Cooled Multistage SOFC-GT Hybrid Power System, developed to maximize fuel heat input to the system. We propose the combination of F-class GT (TIT 1350°C class) and 5 stage SOFC as the best for the hybrid power plant system and 77% (LHV base) is achieved at high pressure ratio.


Sign in / Sign up

Export Citation Format

Share Document