Active Flow Control Techniques on a Stator Compressor Cascade: A Comparison Between Synthetic Jet and Plasma Actuators

Author(s):  
Maria Grazia De Giorgi ◽  
Stefania Traficante ◽  
Carla De Luca ◽  
Daniela Bello ◽  
Antonio Ficarella

In this work a CFD analysis is applied to study the suppression of the boundary layer separation into a highly-loaded subsonic compressor stator cascade, by different active flow control techniques. Active flow control techniques have the potential to delay separation and to increase the pressure ratio. In particular three different techniques have been applied: the actuation by steady jet, by zero net mass flux Synthetic Jet (SJA) and by plasma actuator. Several works have investigated the use of synthetic jet and plasma actuators on the airfoil, but only few studies have compared the effect of these devices. Concerning the synthetic jet actuator, a suction/blowing type boundary condition is used, imposing a prescribed sinusoidal velocity depending on velocity amplitude, jet frequency and jet angle of ejection with respect to the wall. Concerning the plasma actuation, the effect is modeled into numerical flow solvers by adding the paraelectric force that represents the plasma force into the momentum equation. The plasma, generated by Dielectric Barrier Discharge, acts as a momentum source to the boundary layer allowing it to remain attached throughout a larger portion of the airfoil. The time-averaged body force component, acting on the fluid, depends on the frequency and on the applied voltage, the charge density, the electrical field and the dimensional properties of the actuator, like width of the electrodes and gap between the electrodes. Using this numerical model, the effect of plasma actuators to suppress the flow separation over the blade has been investigated, increasing the turbo-machinery performance too. Finally, the comparison between the different actuation devices shows that, reducing the secondary flow structures, each actuation technique beneficially affects the performance of the stator compressor cascade, even if in the steady jet the costs are relevant.

2011 ◽  
Vol 134 (2) ◽  
Author(s):  
Arne Vorreiter ◽  
Susanne Fischer ◽  
Horst Saathoff ◽  
Rolf Radespiel ◽  
Joerg R. Seume

Airfoil active flow control has been attempted in the past in order to increase the permissible loading of boundary layers in gas turbine components. The present paper presents a stator with active flow control for a high-speed compressor using a Coanda surface near the trailing edge in order to inhibit boundary layer separation. The design intent is to reduce the number of vanes while—in order to ensure a good matching with the downstream rotor—the flow turning angle is kept constant. In a first step, numerical simulations of a linear compressor cascade with circulation control are conducted. The Coanda surface is located behind an injection slot on the airfoil suction side. Small blowing rates lead to a gain in efficiency associated with a rise in static pressure. In a second step, this result is transferred to a four-stage high-speed research compressor, where the circulation control is applied in the first stator. The design method and the first results are based on steady numerical calculations. The analysis of these results shows performance benefits of the concept. For both the cascade and the research compressor, the pressure gain and efficiency are shown as a function of blowing rate and jet power ratio. The comparison is performed based on a dimensionless efficiency, which takes into account the change in power loss.


2009 ◽  
Vol 74 ◽  
pp. 157-160
Author(s):  
Jing Chuen Lin ◽  
An Shik Yang ◽  
Li Yu Tseng

The main purpose of active flow control research is to develop a cost-effective technology that has the potential for inventive advances in aerodynamic performance and maneuvering compared to conventional approaches. It can be essential to thoroughly understand the flow characteristics of the formation and interaction of a synthetic jet with external crossflow before formulating a practicable active flow control strategy. In this study, the theoretical model used the transient three-dimensional conservation equations of mass and momentum for compressible, isothermal, turbulent flows. The motion of a movable membrane plate was also treated as the moving boundary by prescribing the displacement on the plate surface. The predictions by the computational fluid dynamics (CFD) code ACE+® were compared with measured transient phase-averaged velocities of Rumsey et al. for software validation. The CFD software ACE+® was utilized for numerical calculations to probe the time evolution of the development process of the synthetic jet and its interaction within a turbulent boundary layer flow for a complete actuation cycle.


Author(s):  
Maria Grazia De Giorgi ◽  
Elisa Pescini ◽  
Fedele Marra ◽  
Antonio Ficarella

Nowadays several active flow control systems, particularly dielectric barrier discharge plasma actuators, appear to be effective for the control of flow stream separation and to improve performance of turbomachinery. However these applications require high actuation strength, higher than the one generated by conventional macro plasma actuators. Research is actually improving the design of plasma actuator in order to enhance the flow control capability and reduce the power consumption. In this contest, this work concerns the implementation of a micro plasma actuator for the active control in a compressor cascade. For this aim, firstly the micro actuator was developed and an experimental characterization of the flow induced by the device was done. The induced flow field was studied by means of Particle Image Velocimetry and Laser Doppler Velocimetry. The dissipated power was also evaluated. Experimental results were used to validate a multi-physics numerical model for the prediction of the body forces induced by the plasma actuator. Finally, the obtained body force field was used for modeling the separation control by means of the micro plasma actuator in a highly-loaded subsonic compressor stator.


Author(s):  
A. Vorreiter ◽  
S. Fischer ◽  
H. Saathoff ◽  
R. Radespiel ◽  
J. R. Seume

Airfoil active flow control has been attempted in the past in order to increase the permissible loading of boundary layers in gas turbine components. The present paper presents a stator with active flow control for a high speed compressor using a Coanda surface near the trailing edge in order to inhibit boundary layer separation. The design intent is to reduce the number of vanes while — in order to ensure a good matching with the downstream rotor — the flow turning angle is kept constant. In a first step, numerical simulations of a linear compressor cascade with circulation control are conducted. The Coanda surface is located behind an injection slot on the airfoil suction side. Small blowing rates lead to a gain in efficiency associated with a rise in static pressure. In a second step, this result is transferred to a 4-stage high speed research compressor, where the circulation control is applied in the first stator. The design method and the first results are based on steady numerical calculations. The analysis of these results shows performance benefits of the concept. For both, the cascade and the research compressor, the pressure gain and efficiency are shown as a function of blowing rate and jet power ratio. The comparison is performed based on a dimensionless efficiency which takes into account the change of power loss.


Author(s):  
F. F. Rodrigues ◽  
J. C. Pascoa ◽  
M. Trancossi

Active flow control by plasma actuators is a topic of great interest by worldwide scientific community. These devices are mainly used for boundary layer control in order to improve the aerodynamic performance of aerial vehicles. Plasma actuators are simple devices that produces a wall bounded jet which allow to control the adjacent flow without moving mechanical parts. Recently, new geometries have been proposed by different authors in an attempt to improve the performance of these devices. In this work, some of these new configurations will be studied and compared considering its ability for boundary layer control applications. Dielectric Barrier Discharge (DBD) plasma actuator, Plasma Synthetic Jet (PSJ) actuator, Multiple Encapsulated Electrodes (MEE) plasma actuator and Curved plasma actuator (or 3D plasma actuator) will be experimentally studied in this work. Plasma actuators power consumption was measured by two different experimental methods. Results for power consumption and power losses of different plasma actuators geometries were presented and discussed.


Author(s):  
Y. Guendogdu ◽  
A. Vorreiter ◽  
J. R. Seume

Aerofoil active flow control has been attempted to increase the permissible loading of boundary layers in gas turbine components. Steady suction and blowing, pulsing and synthetic jets are all means to remove low energy flow, replace momentum deficits, or promote mixing to inhibit boundary layer separation. A curved surface near the trailing edge (“Coanda surface”) is another technique used to control aerofoil boundary layer separation. This paper presents the design of a stator with active flow control for a high speed compressor using a Coanda surface. The Coanda surface is located behind an injection slot on the aerofoil suction side of the first stage of a four-stage high speed research compressor. The design method and the present results are based on steady numerical calculations. The design intent is to reduce the number of vanes. This active flow control is used to maintain the flow exit angle of the reference stator despite the resulting increase in stator loading. It is shown that the solidity of the flow-controlled stator can be decreased by 25% with a blowing rate of 0.5% of the main mass flow.


Author(s):  
V Zander ◽  
M Hecklau ◽  
W Nitsche ◽  
A Huppertz ◽  
M Swoboda

This article presents the potential of active flow control to increase the aerodynamic performance of highly loaded turbomachinery compressor blades. Experimental investigations on a large-scale compressor cascade equipped with 30 synthetic jet actuators mounted to the sidewalls and the blades themselves have been carried out. Results for a variation of the inflow angle, the jet amplitude, and the actuation frequency are presented. The wake measurements show total pressure loss reductions of nearly 10 per cent for the synthetic jet actuation. An efficiency calculation reveals that the energy saved by actuation is nearly twice the energy consumption of the synthetic jets.


2021 ◽  
Author(s):  
F. F. Rodrigues ◽  
J. Nunes-Pereira ◽  
M. Abdollahzadeh ◽  
J. Pascoa ◽  
S. Lanceros-Mendez

Abstract Dielectric Barrier Discharge (DBD) plasma actuators are simple devices with great potential for active flow control applications. Further, it has been recently proven their ability for applications in the area of heat transfer, such as film cooling of turbine blades or ice removal. The dielectric material used in the fabrication of these devices is essential in determining the device performance. However, the variety of dielectric materials studied in the literature is very limited and the majority of the authors only use Kapton, Teflon, Macor ceramic or poly(methyl methacrylate) (PMMA). Furthermore, several authors reported difficulties in the durability of the dielectric layer when the actuators operate at high voltage and frequency. Also, it has been reported that, after long operation time, the dielectric layer suffers degradation due to its exposure to plasma discharge, degradation that may lead to the failure of the device. Considering the need of durable and robust actuators, as well as the need of higher flow control efficiencies, it is highly important to develop new dielectric materials which may be used for plasma actuator fabrication. In this context, the present study reports on the experimental testing of dielectric materials which can be used for DBD plasma actuators fabrication. Plasma actuators fabricated of poly(vinylidene fluoride) (PVDF) and polystyrene (PS) have been fabricated and evaluated. Although these dielectric materials are not commonly used as dielectric layer of plasma actuators, their interesting electrical and dielectric properties and the possibility of being used as sensors, indicate their suitability as potential alternatives to the standard used materials. The plasma actuators produced with these nonstandard dielectric materials were analyzed in terms of electrical characteristics, generated flow velocity and mechanical efficiency, and the obtained results were compared with a standard actuator made of Kapton. An innovative calorimetric method was implemented in order to estimate the thermal power transferred by these devices to an adjacent flow. These results allowed to discuss the ability of these new dielectric materials not only for flow control applications but also for heat transfer applications.


Author(s):  
Marcel Staats ◽  
Wolfgang Nitsche

We present results of experiments on a periodically unsteady compressor stator flow of the type which would be expected in consequence of pulsed combustion. A Reynolds number of Re = 600000 was used for the investigations. The experiments were conducted on the two-dimensional low-speed compressor testing facility in Berlin. A choking device downstream the trailing edges induced a periodic non-steady outflow condition to each stator vane which simulated the impact of a pressure gaining combuster downstream from the last stator. The Strouhal number of the periodic disturbance was Sr = 0.03 w.r.t. the stator chord length. Due to the periodic non-steady outflow condition, the flow-field suffers from periodic flow separation phenomena, which were managed by means of active flow control. In our case, active control of the corner separation was applied using fluidic actuators based on the principle of fluidic amplification. The flow separation on the centre region of the stator blade was suppressed by means of a fluidic blade actuator leading to an overall time-averaged loss reduction of 11.5%, increasing the static pressure recovery by 6.8% while operating in the non-steady regime. Pressure measurements on the stator blade and the wake as well as PIV data proved the beneficial effect of the active flow control application to the flow field and the improvement of the compressor characteristics. The actuation efficiency was evaluated by two figures of merit introduced in this contribution.


Sign in / Sign up

Export Citation Format

Share Document