An Internal Heat Transfer Study in a Cooled Nozzle Guide Vane of a Linear Cascade

Author(s):  
Arun Kumar Pujari ◽  
Prasad B. V. S. S. Subrahmanyaa ◽  
Sitaram Nekkanti

Experimental and computational heat transfer investigations are reported in the interior mid span of the pressure surface of a Nozzle Guide Vane (NGV) subjected to combined impingement and film cooling. The study is carried out by considering a two dimensional cascade domain having four passages formed between the five vane each has a chord length of 228 mm and spacing (between the blades) of 200 mm. The vane internal surface is cooled by two impingement inserts namely front and aft impingement tubes. The front impingement tube is used to cool the internal side of the leading edge of the NGV whereas the aft impingement tube is used to cool mainly the mid span of the internal surface. The mass flow through the impingement chamber is varied for a fixed target plate distance to jet diameter ratio of 1.12. The surface temperature at the mid chord region was measured by liquid crystal technique. The surface temperature obtained from both experiments and computations are compared and the computationally obtained average heat transfer coefficient distribution along chord reported. The flow structure variation along the chord and its effect on Nusselt number distribution is presented. The computation is carried out by using Shear stress transport (SST) k-ω turbulence model in the ANSY FLUENT-14 flow solver.

Author(s):  
Arun Kumar Pujari ◽  
Bhamidi Prasad ◽  
Nekkanti Sitaram

Experimental and computational heat transfer investigations are reported in the interior side of a nozzle guide vane (NGV) subjected to combined impingement and film cooling. The domain of study is a two dimensional five-vane cascade having four passages. Each vane has a chord length of 228 mm and the pitch distance between the vanes is 200 mm. The vane internal surface is cooled by dry air supplied through the two impingement inserts: the front and the aft. The mass flow through the impingement chamber is varied, for a fixed spacing (H) to jet diameter (d) ratio of 1.2. The surface temperature distributions, at certain locations of the vane interior, are measured by pasting strips of liquid crystal sheets. The vane interior surface temperature distribution is also obtained by computations carried out by using Shear stress transport (SST) k-ω turbulence model in the ANSY FLUENT-14 flow solver. The computational data are in good agreement with the measured values of temperature. The internal heat transfer coefficients are thence determined along the leading edge and the mid span region from the computational data.


2020 ◽  
Vol 37 (4) ◽  
pp. 327-342
Author(s):  
Arun Kumar Pujari ◽  
B. V. S. S. S Prasad ◽  
Nekkanti Sitaram

AbstractThe effect of conjugate heat transfer is investigated on a first stage nozzle guide vane (NGV) of a high pressure gas turbine which has both impingement and film cooling holes. The study is carried out computationally by considering a linear cascade domain, having two passages formed between the vanes, with a chord length of 228 mm and spacing of 200 mm. The effect of (i) coolant and mainstream Reynolds numbers, (ii) thermal conductivity (iii) temperature difference between the mainstream and coolant at the internal surface of the nozzle guide vane are investigated under conjugate thermal condition. The results show that, with increasing coolant Reynolds number the lower conducting material shows larger percentage decrease in surface temperature as compared to the higher conducting material. However, the internal surface temperature is nearly independent of mainstream Reynolds number variation but shows significant variation for higher conducting material. Further, the temperature gradient within the solid thickness of NGV is higher for the lower conductivity material.


Author(s):  
Arun Kumar Pujari ◽  
B. V. S. S. S. Prasad ◽  
Nekkanti Sitaram

Experimental and computational heat transfer investigations are reported on the interior side of a nozzle guide vane (NGV) subjected to combined impingement and film cooling. The domain of study is a two-dimensional five-vane cascade having a space chord ratio of 0.88. The vane internal surface is cooled by dry air, supplied through the two impingement inserts: the front and the aft. The blowing ratio (ρcVc/ρmVm) is varied systematically by varying the coolant mass flow through the impingement chamber and also by changing the mainstream Reynolds number, but by keeping a fixed spacing (H) to jet diameter (d) ratio of 1.2. The surface temperature distributions, at certain locations of the vane interior surface, are measured by pasting strips of liquid crystal sheets. The vane interior surface temperature distribution is also obtained by the computations carried out by using shear stress transport (SST) k–ω turbulence model in the flow solver ansys fluent-14. The computational data are in good agreement with the measured values of temperature. The internal heat transfer coefficients are thence determined from the computational data. The results show that, when the blowing ratio is increased by increasing the coolant flow rate, the average internal surface temperature decreases. However, when the blowing ratio is varied by increasing the mainstream Reynolds number, the internal surface temperature increases. Further, the temperature variations are different all along the internal surface from the leading edge to the trailing edge and are largely dependent on the coolant flow distributions on the internal as well as the external sides.


2018 ◽  
Vol 0 (0) ◽  
Author(s):  
Arun Kumar Pujari ◽  
B. V. S. S. S Prasad ◽  
Nekkanti Sitaram

Abstract Conjugate heat transfer analysis is carried out in a cascade domain for a nozzle guide vane. The nozzle guide vane is internally cooled by jet impingement cooling, and the external surface is cooled by film cooling. A computational study was carried out with three different materials, having conductivity values of 0.0048, 0.2 and 1.1 W/m.K. Distribution of local surface temperature along the leading edge, pressure and suction surface is reported. The leading edge region showed the maximum increase in internal surface temperature as the conductivity increased among the different regions of the vane internal surface. However, the pressure and suction surfaces showed relatively less increase in the surface temperature distribution. In order to validate the computational result, the obtained temperature data were compared with experimentally obtained surface temperature data. The flow phenomena like jet lift-off and self-induced cross-flow affect the local temperature distribution differently in the three materials. For a constant mainstream and coolant flow, the surface temperature gradient is higher for the lower conductivity material, and the gradient decreases as conductivity increases. Hence, a material with higher conductivity is desired in a combined impingement and film cooled nozzle guide vane, to increase the durability of the vane.


2019 ◽  
Vol 0 (0) ◽  
Author(s):  
Arun Kumar Pujari

Abstract Conjugate heat transfer analysis is carried out on the internal surface of the first-stage nozzle guide vane of a gas turbine, which has both impingement and film cooling holes. The mainstream flow Reynolds number and internal coolant flow Reynolds number systematically changed and its effect on internal local surface temperature variation is studied. It is found that an increase in the coolant mass flow rate causes a non-uniform decrease in the local internal surface temperature. The external film coolant jet-lift off and internal impingement cross-flow are significant contributors to the non-uniform variation in surface temperature. It is also observed that the leading edge regions are prone to jet lift-off, whereas the tip regions of the suction surface are prone to self-induced cross-flow, due to which hot patches are formed in these regions. Hot patches are observed near the hub regions of a pressure surface due to the reduced film thickness on the external surface. From these observations it is concluded that local values of internal surface temperature are differently affected in different regions of the vane surface for a given combination of mainstream and coolant flow rates. Therefore, the conventional method of obtaining the internal temperature distributions by considering generalized geometries may not yield accurate solutions, in predicting the life of the nozzle guide vane.


Author(s):  
Luca Andrei ◽  
Carlo Carcasci ◽  
Riccardo Da Soghe ◽  
Bruno Facchini ◽  
Francesco Maiuolo ◽  
...  

An experimental survey on a state of the art leading edge cooling scheme was performed to evaluate heat transfer coefficients (HTC) on a large scale test facility simulating an high pressure turbine airfoil leading edge cavity. Test section includes a trapezoidal supply channel with three large racetrack impingement holes. On the internal surface of the leading edge, four big fins are placed in order to confine impingement jets. The coolant flow impacts the leading edge internal surface and it is extracted from the leading edge cavity through 24 showerhead holes and 24 film cooling holes. The aim of the present study is to investigate the combined effects of jet impingement and mass flow extraction on the internal heat transfer of the leading edge. A non uniform mass flow extraction was also imposed to reproduce the effects of pressure side and suction side external pressure. Measurements were performed by means of a transient technique using narrow band Thermo-chromic Liquid Crystals (TLC). Jet Reynolds number and crossflow conditions into the supply channel were varied in order to cover the typical engine conditions of these cooling systems (Rej = 10000–40000). Experiments were compared with a numerical analysis on the same test case in order to better understand flow interaction inside the cavity. Results are reported in terms of detailed 2D maps, radial-wise and span-wise averaged values of Nusselt number.


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Luca Andrei ◽  
Carlo Carcasci ◽  
Riccardo Da Soghe ◽  
Bruno Facchini ◽  
Francesco Maiuolo ◽  
...  

An experimental survey on a state of the art leading edge cooling scheme was performed to evaluate heat transfer coefficients (HTC) on a large scale test facility simulating a high pressure turbine airfoil leading edge cavity. The test section includes a trapezoidal supply channel with three large racetrack impingement holes. On the internal surface of the leading edge, four big fins are placed in order to confine impingement jets. The coolant flow impacts the leading edge internal surface, and it is extracted from the leading edge cavity through 24 showerhead holes and 24 film cooling holes. The aim of the present study is to investigate the combined effects of jet impingement and mass flow extraction on the internal heat transfer of the leading edge. A nonuniform mass flow extraction was also imposed to reproduce the effects of the pressure side and suction side external pressure. Measurements were performed by means of a transient technique using narrow band thermochromic liquid crystals (TLCs). Jet Reynolds number and crossflow conditions into the supply channel were varied in order to cover the typical engine conditions of these cooling systems (Rej=10,000-40,000). Experiments were compared with a numerical analysis on the same test case in order to better understand flow interaction inside the cavity. Results are reported in terms of detailed 2D maps, radial-wise, and span-wise averaged values of Nusselt number.


2017 ◽  
Vol 139 (11) ◽  
Author(s):  
Ioanna Aslanidou ◽  
Budimir Rosic

This paper presents an experimental investigation of the concept of using the combustor transition duct wall to shield the nozzle guide vane leading edge. The new vane is tested in a high-speed experimental facility, demonstrating the improved aerodynamic and thermal performance of the shielded vane. The new design is shown to have a lower average total pressure loss than the original vane, and the heat transfer on the vane surface is overall reduced. The peak heat transfer on the vane leading edge–endwall junction is moved further upstream, to a region that can be effectively cooled as shown in previously published numerical studies. Experimental results under engine-representative inlet conditions showed that the better performance of the shielded vane is maintained under a variety of inlet conditions.


Author(s):  
Hans Reiss ◽  
Albin Bölcs

Film cooling and heat transfer measurements were carried out on a cooled nozzle guide vane in a linear cascade, using a transient liquid crystal technique. Three flow conditions were realized: the nominal operating condition of the vane with an exit Reynolds number of 1.47e6, as well as two lower flow conditions: Re2L = 1.0e6 and 7.5e5. The vane model was equipped with a single row of inclined round film cooling holes with compound angle orientation on the suction side. Blowing ratios ranging form 0.3 to 1.5 were covered, all using foreign gas injection (CO2) yielding an engine-representative density ratio of 1.6. Two distinct states of the incoming boundary layer onto the injection station were compared, an undisturbed laminar boundary layer as it forms naturally on the suction side, and a fully turbulent boundary layer which was triggered with a trip wire upstream of injection. The aerodynamic flow field is characterized in terms of profile Mach number distribution, and the associated heat transfer coefficients around the uncooled airfoil are presented. Both detailed and spanwise averaged results of film cooling effectiveness and heat transfer coefficients are shown on the suction side, which indicate considerable influence of the state of the incoming boundary layer on the performance of a film cooling row. The influence of the mainstream flow condition on the film cooling behavior at constant blowing ratio is discussed for three chosen injection regimes.


Author(s):  
A. A. Thrift ◽  
K. A. Thole ◽  
S. Hada

Heat transfer is a critical factor in the durability of gas turbine components, particularly in the first vane. An axisymmetric contour is sometimes used to contract the cross sectional area from the combustor to the first stage vane in the turbine. Such contouring can lead to significant changes in the endwall flows thereby altering the heat transfer. This paper investigates the effect of axisymmetric contouring on endwall heat transfer of a nozzle guide vane. Heat transfer measurements are performed on the endwalls of a planar and contoured passage whereby one endwall is modified with a linear slope in the case of the contoured passage. Included in this study is upstream leakage flow issuing from a slot normal to the inlet axis. Each of the endwalls within the contoured passage presents a unique flowfield. For the contoured passage, the flat endwall is subject to an increased acceleration through the area contraction while the contoured endwall includes both increased acceleration and a turning of streamlines due to the slope. Results indicate heat transfer is reduced on both endwalls of the contoured passage relative to the planar passage. In the case of all endwalls, increasing leakage mass flow rate leads to an increase in heat transfer near the suction side of the vane leading edge.


Sign in / Sign up

Export Citation Format

Share Document