Assessment of Heat-Transfer Correlations Against Experimental Data Obtained With Supercritical Water in Vertical Annuli

Author(s):  
Zhendong Yang ◽  
Qincheng Bi ◽  
Han Wang ◽  
Gang Wu ◽  
Laurence K. H. Leung

Eleven correlations proposed for supercritical heat-transfer coefficients were assessed against a set of experimental data obtained recently with supercritical water flow in a vertical annular test section at Xi’an Jiaotong University. The inner heated rod of the test section had an outer diameter of 8 mm, while the outer unheated tube had an inner diameter of 16 mm (resulting in a gap size of 4 mm). The experiment covered pressure range from 23 to 28 MPa, mass-flux range from 350 to 1000 kg/m2s, and heat-flux range from 200 to 1000 kW/m2. The assessment shows relatively good agreement between predicted and experimental heat-transfer coefficients for several correlations. Some discrepancies have been observed at the region where deteriorated heat transfer, and are attributed to the modified Dittus-Boelter formulation that captures mainly the normal heat-transfer region. Overall, the Dittus-Boelter correlation is shown applicable only for the normal heat-transfer region, and significantly overpredicts the heat-transfer coefficient at the deteriorated heat-transfer region. The correlation of Bishop et al. appears valid for the current experimental database, particularly for high mass fluxes.

2018 ◽  
Vol 140 (6) ◽  
Author(s):  
Gerrit A. Schatte ◽  
Andreas Kohlhepp ◽  
Tobias Gschnaidtner ◽  
Christoph Wieland ◽  
Hartmut Spliethoff

Heat transfer to supercritical water in heated tubes and channels is relevant for steam generators in conventional power plants and future concepts for supercritical nuclear and solar-thermal power plants. A new experimental facility, the high pressure evaporation rig, setup at the Institute for Energy Systems (Technische Universität München) aims to provide heat transfer data to fill the existing knowledge gaps at these conditions. The test rig consists of a closed-loop high pressure cycle, in which de-ionized water is fed to an instrumented test section heated by the application of direct electrical current. It is designed to withstand a maximum pressure of 380 bar at 580 °C in the test section. The maximum power rating of the system is 1 MW. The test section is a vertical tube (material: AISI A213/P91) with a 7000 mm heated length, a 15.7 mm internal diameter, and a wall thickness of 5.6 mm. It is equipped with 70 thermocouples distributed evenly along its length. It enables the determination of heat transfer coefficients in the supercritical region at various steady-state or transient conditions. In a first series of tests, experiments are conducted to investigate normal and deteriorated heat transfer (DHT) under vertical upward flow conditions. The newly generated data and literature data are used to evaluate different correlations available for modeling heat transfer coefficients at supercritical pressures.


Author(s):  
Ajay Kumar Kaviti ◽  
Akkala Siva Ram ◽  
Amit Kumar Thakur

In this experimental study, permanent magnets with three different sizes (M-1: 32 mm inner diameter, 70 mm outer diameter and 15 mm thick, M-2: 25 mm inner diameter, 60 mm outer diameter and 10 mm thick, M-3: 22 mm inner diameter, 45 mm outer diameter and 9 mm thick) are fully submerged in the single-slope glass solar still. The performance of magnetic solar stills (MSS) with three different sizes at 2 cm depth water to ensure that magnets are fully submerged is compared with conventional solar still (CSS) at the location 17.3850°N, 78.4867°E. Tiwari model is adapted to calculate the heat transfer coefficients (HTC), internal and exergy efficiencies. MSS with M-1, M-2 and M-3 significantly enhanced the convective, radiative, and evaporative heat transfer rate for the 2 cm depth of water. This is due to the desired magnetic treatment of water, which reduces the surface tension and increases the hydrogen bonds. The MSS's total internal HTC, instantaneous efficiencies led CSS by 25.52%, 28.8%, respectively, with M-1. Having various magnetic fields due to different magnets sizes increases MSS's exergetic efficiency by 33.61% with M-1, 33.76% with M-2, and 42.25% with M-3. Cumulative yield output for MSS with M-1, M-2, and M-3 is 21.66%, 17.64%, 15.78% higher than CSS. The use of permanent magnets of different sizes in the MSS is a viable, economical and straight forward technique to enhance productivity.


Author(s):  
Lindsey V. Randle ◽  
Brian M. Fronk

Abstract In this study, we use infrared thermography to calculate local heat transfer coefficients of top and bottom heated flows of near-critical carbon dioxide in an array of parallel microchannels. These data are used to evaluate the relative importance of buoyancy for different flow arrangements. A Joule heated thin wall made of Inconel 718 applies a uniform heat flux either above or below the horizontal flow. A Torlon PAI test section consists of three parallel microchannels with a hydraulic diameter of 923 μm. The reduced inlet temperature (TR = 1.006) and reduced pressure (PR = 1.03) are held constant. For each heater orientation, the mass flux (520 kgm−2s−2 ≤ G ≤ 800 kgm−2s−2) and heat flux (4.7 Wcm−2 ≤ q″ ≤ 11.1 Wcm−2) are varied. A 2D resistance network analysis method calculates the bulk temperatures and heat transfer coefficients. In this analysis, we divide the test section into approximately 250 segments along the stream-wise direction. We then calculate the bulk temperatures using the enthalpy from the upstream segment, the heat flux in a segment, and the pressure. To isolate the effect of buoyancy, we screen the data to omit conditions where flow acceleration may be important or where relaminarization may occur. In the developed region of the channel, there was a 10 to 15 percent reduction of the local heat transfer coefficients for the upward heating mode compared to downward heating with the same mass and heat fluxes. Thus buoyancy effects should be considered when developing correlations for these types of flow.


Author(s):  
Yantao Li ◽  
Yulong Ji ◽  
Katsuya Fukuda ◽  
Qiusheng Liu

Abstract This paper presents an experimental investigation of the forced convective heat transfer of FC-72 in vertical tubes at various velocities, inlet temperatures, and tube sizes. Exponentially escalating heat inputs were supplied to the small tubes with inner diameters of 1, 1.8, and 2.8 mm and effective heated lengths between 30.1 and 50.2 mm. The exponential periods of heat input range from 6.4 to 15.5 s. The experimental data suggest that the convective heat transfer coefficients increase with an increase in flow velocity and µ/µw (refers to the viscosity evaluated at the bulk liquid temperature over the liquid viscosity estimated at the tube inner surface temperature). When tube diameter and the ratio of effective heated length to inner diameter decrease, the convective heat transfer coefficients increase as well. The experimental data were nondimensionalized to explore the effect of Reynolds number (Re) on forced convection heat transfer coefficient. It was found that the Nusselt numbers (Nu) are influenced by the Re for d = 2.8 mm in the same pattern as the conventional correlations. However, the dependences of Nu on Re for d = 1 and 1.8 mm show different trends. It means that the conventional heat transfer correlations are inadequate to predict the forced convective heat transfer in minichannels. The experimental data for tubes with diameters of 1, 1.8, and 2.8 mm were well correlated separately. And, the data agree with the proposed correlations within ±15%.


Author(s):  
Kwang-Hyun Bang ◽  
Kun-Eui Hong ◽  
In-Seon Hwang

This paper reports an experimental study on flow boiling of water in a minichannel. Flow boiling heat transfer coefficients and pressure drops were measured and the data were compared with existing correlations. The effect of pressure was the major objectives in this study and the range of pressure was 1 to 18 bars. The experimental apparatus consisted mainly of a minichannel test section, gear pump, pre-heater, pressurizer, condenser and evaporator. The evaporator was used for variation of vapor quality at the inlet of test section. The pressurizer controls the desired system pressure. The test section is a round tube of 1.73 mm inside diameter, made of 316 stainless steel. The test section and the evaporator tubes were heated by DC electric current through the tubes. The measured flow boiling heat transfer coefficients showed two distinct regions; relatively high heat transfer coefficients at low vapor quality and lower heat transfer coefficients at higher vapor quality. This observation implies the change of flow regime, slug to annular flow. Comparisons of the experimental data and the prediction of correlations (Gungor & Winterton, 1987; Tran et al., 1996; Kandlikar, 2003) showed large discrepancy in both regions.


Author(s):  
Vishal Ramesh ◽  
Sandip Mazumder ◽  
Gurpreet Matharu ◽  
Dhaval Vaishnav ◽  
Syed Ali ◽  
...  

A combined Computational Fluid Dynamics (CFD) and experimental approach is presented to determine (calibrate) the external convective heat transfer coefficients (h) around a partially-filled water tank cooled in a climactic chamber. A CFD analysis that includes natural convection in both phases (water and air) was performed using a 2D-axisymmetric tank model with three prescribed average heat transfer coefficients for the top, side and bottom walls of the tank. The commercial CFD code ANSYS-Fluent™, along with User-Defined Functions (UDFs), were utilized to compute and extract temperature vs. time curves at five different thermocouple locations within the tank. The prescribed h values were then altered to match experimentally obtained temperature-time data at the same locations. The calibration was deemed successful when results from the simulations exhibited match with experimental data within ±2°C for all thermocouples. The calibrated h values were finally used in full-scale 3D simulations and compared to the experimental data to test their accuracy. Predicted 3D results were found to agree with experimental results within the error of the calibration, thereby lending credibility to the overall approach.


2013 ◽  
Vol 135 (7) ◽  
Author(s):  
Mehmed Rafet Özdemir ◽  
Ali Koşar

The pressure drop and heat transfer due to the flow of de-ionized water at high mass fluxes in microtubes of ∼ 254 μm and ∼ 685 μm inner diameters is investigated in the laminar, transition and the turbulent flow regimes. The flow is hydrodynamically fully developed and thermally developing. The experimental friction factors and heat transfer coefficients are respectively predicted to within ±20% and ±30% by existing open literature correlations. Higher single phase heat transfer coefficients were obtained with increasing mass fluxes, which is motivating to operate at high mass fluxes and under thermally developing flow conditions. The transition to turbulent flow and friction factors for both laminar and turbulent conditions were found to be in agreement with existing theory. A reasonable agreement was present between experimental results and theoretical predictions recommended for convective heat transfer in thermally developing flows.


Author(s):  
Jiang Lei ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han ◽  
Luzeng Zhang ◽  
Hee-Koo Moon

This paper experimentally investigates the effect of a turning vane on hub region heat transfer in a multi-pass rectangular smooth channel at high rotation numbers. The experimental data were taken in the second and the third passages (Aspect Ratio = 2:1) connected by an 180° U-bend. The flow was radial inward in the second passage and was radial outward after the 180° U-bend in the third passage. The Reynolds number ranged 10,000 to 40,000 while the rotation number ranged 0 to 0.42. The density ratio was a constant of 0.12. Results showed that rotation increases heat transfer on leading surface but decreases it on the trailing surface in the second passage. In the third passage, the effect of rotation is reversed. Without a turning vane, rotation reduces heat transfer substantially on all surfaces in the hub 180° turn region. After adding a half-circle-shaped turning vane, heat transfer coefficients do not change in the second passage (before turn) while they are quite different in the turn region and the third passage (after turn). Regional heat transfer coefficients are correlated with rotation numbers for multi-pass rectangular smooth channel with and without a turning vane.