Numerical Simulation of Supercritical Water Heat Transfer in the Vertically Heated Tube

Author(s):  
Feng Wang ◽  
Bo Cui ◽  
Shijun Zhang ◽  
Xue Qin

The heat transfer of water in a vertically heated tube at 24.52 MPa is numerically simulated by computational fluid dynamics software of FLUENT. The IAPWS-IF97 formulation is applied to obtain the water properties, which vary substantially at supercritical condition. The two-dimensional axi-symmetric model using RNG k-ε turbulence model with enhanced wall treatment gives fine prediction of wall temperature and heat transfer coefficient. The mesh size near the wall adapted smaller when at high heat fluxes for the accuracy of computed results. The wall heat fluxes were set to be 233, 698, 930 and 1100 kW/m2 to match the simulation with experiment performed by Yamagata. It is found that k-ε turbulence model with enhanced wall treatment can give outstanding prediction of heat transfer enhancement and heat transfer deterioration. The heat transfer coefficient value reaches a maximum near the pseudocritical point and it decreases with increase of heat flux.

1969 ◽  
Vol 91 (1) ◽  
pp. 27-36 ◽  
Author(s):  
B. S. Shiralkar ◽  
Peter Griffith

At slightly supercritical pressure and in the neighborhood of the pseudocritical temperature (which corresponds to the peak in the specific heat at the operating pressure), the heat transfer coefficient between fluid and tube wall is strongly dependent on the heat flux. For large heat fluxes, a marked deterioration takes place in the heat transfer coefficient in the region where the bulk temperature is below the pseudocritical temperature and the wall temperature above the pseudocritical temperature. Equations have been developed to predict the deterioration in heat transfer at high heat fluxes and the results compared with previously available results for steam. Experiments have been performed with carbon dioxide for additional comparison. Limits of safe operation for a supercritical pressure heat exchanger in terms of the allowable heat flux for a particular flow rate have been determined theoretically and experimentally.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
Zhenfeng Wang ◽  
Peigang Yan ◽  
Hongfei Tang ◽  
Hongyan Huang ◽  
Wanjin Han

The different turbulence models are adopted to simulate NASA-MarkII high pressure air-cooled gas turbine. The experimental work condition is Run 5411. The paper researches that the effect of different turbulence models for the flow and heat transfer characteristics of turbine. The turbulence models include: the laminar turbulence model, high Reynolds number k-ε turbulence model, low Reynolds number turbulence model (k-ω standard format, k-ω-SST and k-ω-SST-γ-θ) and B-L algebra turbulence model which is adopted by the compiled code. The results show that the different turbulence models can give good flow characteristics results of turbine, but the heat transfer characteristics results are different. Comparing to the experimental results, k-ω-SST-θ-γ turbulence model results are more accurate and can simulate accurately the flow and heat transfer characteristics of turbine with transition flow characteristics. But k-ω-SST-γ-θ turbulence model overestimates the turbulence kinetic energy of blade local region and makes the heat transfer coefficient higher. It causes that local region temperature is higher. The results of B-L algebra turbulence model show that the results of B-L model are accurate besides it has 4% temperature error in the transition region. As to the other turbulence models, the results show that all turbulence models can simulate the temperature distribution on the blade pressure surface except the laminar turbulence model underestimates the heat transfer coefficient of turbulence flow region. On the blade suction surface with transition flow characteristics, high Reynolds number k-ε turbulence model overestimates the heat transfer coefficient and causes the blade surface temperature is high about 90K than the experimental result. Low Reynolds number k-ω standard format and k-ω-SST turbulence models also overestimate the blade surface temperature value. So it can draw a conclusion that the unreasonable choice of turbulence models can cause biggish errors for conjugate heat transfer problem of turbine. The combination of k-ω-SST-γ-θ model and B-L algebra model can get more accurate turbine thermal environment results. In addition, in order to obtain the affect of different turbulence models for gas turbine conjugate heat transfer problem. The different turbulence models are adopted to simulate the different computation mesh domains (First case and Second case). As to each cooling passages, the first case gives the wall heat transfer coefficient of each cooling passages and the second case considers the conjugate heat transfer course between the cooling passages and blade. It can draw a conclusion that the application of heat transfer coefficient on the wall of each cooling passages avoids the accumulative error. So, for the turbine vane geometry models with complex cooling passages or holes, the choice of turbulence models and the analysis of different mesh domains are important. At last, different turbulence characteristic boundary conditions of turbine inner-cooling passages are given and K-ω-SST-γ-θ turbulence model is adopted in order to obtain the effect of turbulence characteristic boundary conditions for the conjugate heat transfer computation results. The results show that the turbulence characteristic boundary conditions of turbine inner-cooling passages have a great effect on the conjugate heat transfer results of high pressure gas turbine.


Author(s):  
Brandon Hulet ◽  
Andres Martinez ◽  
Melanie Derby ◽  
Amy Rachel Betz

This research experimentally investigates the heat transfer performance of open-micro channels under filmwise condensation conditions. Filmwise condensation is an important factor in the design of steam condensers used in thermoelectric power generation, desalination, and other industrial applications. Filmwise condensation averages five times lower heat transfer coefficients than those present in dropwise condensation, and filmwise condensation is the dominant condensation regime in the steam condensers due to a lack of a durable dropwise condensation surface. Film thickness is also of concern because it is directly proportional to the condenser’s overall thermal resistance. This research focuses on optimizing the channel size to inhibit the creation of a water film and/or to reduce its overall thickness in order to maximize the heat transfer coefficient of the surface. Condensation heat transfer was measured in three square channels and a plane surface as a control. The sizes of the square fins were 0.25 mm; 0.5 mm; and 1 mm, and tests were done at a constant pressure of 6.2 kPa. At lower heat fluxes, the 0.25mm fins perform better, whereas at larger heat fluxes a smooth surface offers better performance. At lower heat fluxes, droplets are swept away by gravity before the channels are flooded. Whereas, at higher heat fluxes, the channels are flooded increasing the total film thickness, thereby reducing the heat transfer coefficient.


Author(s):  
Fangpan Zhong ◽  
Chao Zhou ◽  
H. Ma ◽  
Q. Zhang

Understanding the heat transfer of winglet tips is crucial for their applications in high-pressure turbines. The current paper investigates the heat transfer performance of three different winglet-cavity tips in a transonic turbine cascade at a tip gap of 2.1% chord. A cavity tip is studied as the baseline case. The cascade operates at engine representative conditions of an exit Mach number of 1.2 and an exit Reynolds number of 1.7 × 106. Transient infrared thermography technique was used to obtain the tip distributions of heat transfer coefficient for different tips in the experiment. The CFD results were validated with the measured tip heat transfer coefficients, and then used to explain the flow physics related to heat transfer. It is found that on the pressure side winglet, the flow reattaches on the top winglet surface and results in high heat transfer coefficient. On the suction side winglet, the heat transfer coefficient is low near the blade leading edge but is higher from the midchord to the trailing edge. The suction side winglet pushes the tip leakage vortex further away from the blade suction surface and reduces the heat transfer coefficient from 85% to 96% span on the blade suction surface. However, the heat transfer coefficient is higher for the winglet tips from 96% span to the tip. This is because the tip leakage vortex attaches on the side surface of the suction side winglet and results in quite high heat transfer coefficient on the front protrusive part of the winglet. The effects of relative endwall motion between the blade tip and the casing were investigated by CFD method. The endwall motion has a significant effect on the flow physics within the tip gap and near-tip region in the blade passage, thus affects the heat transfer coefficient distributions. With relative endwall motion, a scraping vortex forms inside the tip gap and near the casing, and the cavity vortex gets closer to the pressure side squealer/winglet. The tip leakage vortex in the blade passage becomes closer to the blade suction surface, resulting in an increase of the heat transfer coefficient.


2014 ◽  
Vol 136 (2) ◽  
Author(s):  
T. David ◽  
D. Mendler ◽  
A. Mosyak ◽  
A. Bar-Cohen ◽  
G. Hetsroni

The thermal characteristics of a laboratory pin-fin microchannel heat sink were empirically obtained for heat flux, q″, in the range of 30–170 W/cm2, mass flux, m, in the range of 230–380 kg/m2 s, and an exit vapor quality, xout, from 0.2 to 0.75. Refrigerant R 134a (HFC-134a) was chosen as the working fluid. The heat sink was a pin-fin microchannel module installed in open flow loop. Deviation from the measured average temperatures was 1.5 °C at q = 30 W/cm2, and 2.0 °C at q = 170 W/cm2. These results indicate that use of pin-fin microchannel heat sink enables keeping an electronic device near uniform temperature under steady state and transient conditions. The heat transfer coefficient varied significantly with refrigerant quality and showed a peak at an exit vapor quality of 0.55 in all the experiments. At relatively low heat fluxes and vapor qualities, the heat transfer coefficient increased with vapor quality. At high heat fluxes and vapor qualities, the heat transfer coefficient decreased with vapor quality. A noteworthy feature of the present data is the larger magnitude of the transient heat transfer coefficients compared to values obtained under steady state conditions. The results of transient boiling were compared with those for steady state conditions. In contrast to the more common techniques, the low cost technique, based on open flow loop was developed to promote cooling using micropin fin sinks. Results of this experimental study may be used for designing the cooling high power laser and rocket-born electronic devices.


2017 ◽  
Vol 64 (4) ◽  
pp. 519-531 ◽  
Author(s):  
Amir Arya ◽  
Saeed Shahmiry ◽  
Vahid Nikkhah ◽  
Mohamad Mohsen Sarafraz

Abstract Experimental investigation was conducted on the thermal performance and pressure drop of a convective cooling loop working with ZnO aqueous nanofluids. The loop was used to cool a flat heater connected to an AC autotransformer. Influence of different operating parameters, such as fluid flow rate and mass concentration of nanofluid on surface temperature of heater, pressure drop, friction factor and overall heat transfer coefficient was investigated and briefly discussed. Results of this study showed that, despite a penalty for pressure drop, ZnO/water nanofluid was a promising coolant for cooling the micro-electronic devices and chipsets. It was also found that there is an optimum for concentration of nanofluid so that the heat transfer coefficient is maximum, which was wt. % = 0.3 for ZnO/water used in this research. In addition, presence of nanoparticles enhanced the friction factor and pressure drop as well; however, it is not very significant in comparison with those of registered for the base fluid.


2011 ◽  
Vol 204-210 ◽  
pp. 1481-1484
Author(s):  
Zhong Min Wan ◽  
Zheng Kai Tu ◽  
Jing Liu

A novel porous micro heat sink system is presented for thermal management of high power LEDs, which has high heat transport capability. Numerical model for the micro heat sink is developed to describe liquid flow and heat transfer based on the local thermal equilibrium of porous media, and it is solved with SIMPLE algorithm. The numerical results show that the heated surface temperature of porous micro heat sink is low at high heat fluxes and is much less than the bearable temperature level of LED chips. The heat transfer coefficient of heat sink is very high, and increasing the liquid velocity can enhance the average heat transfer coefficient. The overall pressure loss of heat sink system increases with the increasing the inlet velocity, but the overall pressure drop is much less than the pumping pressure provided by micro pump.


1994 ◽  
Vol 116 (3) ◽  
pp. 670-678 ◽  
Author(s):  
S. B. Memory ◽  
S. V. Chilman ◽  
P. J. Marto

Heat transfer measurements were made during nucleate boiling of R-113 from a bundle of 15 electrically heated, copper TURBO-B tubes arranged in an equilateral triangular pitch, designed to simulate a portion of a flooded evaporator. Five of the tubes that were oriented in a vertical array on the centerline of the bundle were each instrumented with six wall thermocouples. For increasing heat flux, the incipient boiling wall superheat of upper tubes decreased as lower tubes were activated. In the boiling region at low heat fluxes (≈ 1 kW/m2), the average bundle heat transfer coefficient was 4.6 times that obtained for a smooth tube bundle (under identical conditions) and 1.6 times greater than that obtained for a single TURBO-B tube; a similar bundle factor has been reported for a smooth tube bundle. At high heat fluxes (100 kW/m2), the average bundle heat transfer coefficient was 3.6 times that of a smooth tube bundle. Furthermore, there was still a significant bundle factor (1.22), contrary to a smooth tube bundle, where all effect of lower tubes was eliminated at high heat fluxes.


1970 ◽  
Vol 92 (3) ◽  
pp. 465-471 ◽  
Author(s):  
B. Shiralkar ◽  
P. Griffith

An investigation has been made of the factors governing the heat transfer coefficient to supercritical pressure fluids, particularly at high heat fluxes. The deterioration in heat transfer to supercritical carbon dioxide has been experimentally studied with reference to the operating conditions of mass velocity and heat flux, tube diameter, orientation, tape induced swirl, inlet temperature, and pressure. A detailed comparison has been made with the apparently contradictory results of other investigators, and operating regions, in which the heat transfer coefficient behaves differently, have been defined. The terms used to describe these regions are the Reynolds number, a heat-flux parameter, and a free-convection parameter.