An Experimental Study of Closed Loop Two-Phase Thermosyphon for Spent Fuel Pool Passive Cooling

Author(s):  
Minglu Wang ◽  
Mingguang Zheng ◽  
Cheng Ye ◽  
Zhongming Qiu ◽  
Zhenqin Xiong

The study reported here examined a closed loop two-phase thermosyphon (CLTPT) of evaporator length 7.6m and internal diameter 65mm used to cool the spent fuel pool. This experimental study investigates the thermal performances and heat and mass transfer characteristic of CLTPT by examining the thermodynamic cycles and overall thermal resistances with ammonia, R134a and water as the working fluid. Measurements of temperature and pressure distributions of the fluid around the loop were made under various conditions. Results show that this loop operates with low filling ratio, low mass flow rate, and high heat-transfer coefficient and the CLTPT has the ability to cool the spent fuel pool. The working fluid flowing through the heat pipe evaporator section generally experienced a subcooled zone, pool boiling zone and high gas quality two-phase region. The average heat transfer coefficient of evaporator reaches 450 W/m2•°C using R134a as working fluid. The thermal resistance of R134a is always smaller than ammonia but the thermal resistance of water is largest at small temperature difference while is smallest when temperature difference is large.

2014 ◽  
Vol 592-594 ◽  
pp. 1554-1558 ◽  
Author(s):  
N. Narendra Babu ◽  
Rudra Naik

Pulsating heat pipe (PHP) is a passive heat transfer device, which transfers heat from one region to another with exceptional heat transfer capacity. It utilizes the latent heat of vaporization of the working fluid as well as the sensible heat. As a result, the effective thermal conductivity is higher than that of the conductors. An experimental study on three turn closed loop pulsating heat pipe with three different working fluids viz., Acetone, Methanol, Heptane and distilled water were employed. The PHP is made up of brass material with an inner diameter of 1.95mm, with a total length of 1150 mm for different fill ratios (FR) was employed .The PHP is tested for the thermal resistance and the heat transfer coefficient. The experimental result strongly demonstrates that acetone is a better working fluid among the working fluids considered in terms of higher heat transfer coefficient and lower thermal resistance.


Author(s):  
Hongbin He ◽  
Biao Shen ◽  
Sumitomo Hidaka ◽  
Koji Takahashi ◽  
Yasuyuki Takata

Heat transfer characteristic of a closed two-phase thermosyphon with enhanced boiling surface is studied and compared with that of a copper mirror surface. Two-phase cooling improves heat transfer coefficient (HTC) a lot compared to single-phase liquid cooling. The evaporator surfaces, coated with a pattern of hydrophobic circle spots (non-electroplating Ni-PTFE, 0.5∼2 mm in diameter and 1.5–3 mm in pitch) on Cu substrates, achieve very high heat transfer coefficient and lower the incipience temperature overshoot using water as the working fluid. Sub-atmospheric boiling on the hydrophobic spot-coated surface shows a much better heat transfer performance. Tests with heat loads (30 W to 260 W) reveals the coated surfaces enhance nucleate boiling performance by increasing the bubbles nucleation sites density. Hydrophobic circle spots coated surface with diameter 1 mm, pitch 1.5 mm achieves the maximal heat transfer enhancement with the minimum boiling thermal resistance as low as 0.03 K/W. The comparison of three evaporator surfaces with same spot parameters but different coating materials is carried out experimentally. Ni-PTFE coated surface with immersion method performs the optimal performance of the thermosyphon.


2001 ◽  
Author(s):  
S. I. Haider ◽  
Yogendra K. Joshi ◽  
Wataru Nakayama

Abstract The study presents a model for the two-phase flow and heat transfer in the closed loop, two-phase thermosyphon (CLTPT) involving co-current natural circulation. Most available models deal with two-phase thermosyphons with counter-current circulation within a closed, vertical, wickless heat pipe. The present research focuses on CLTPTs for electronics cooling that face more complex two-phase flow patterns than the vertical heat pipes, due to closed loop geometry and smaller tube size. The present model is based on mass, momentum, and energy balances in the evaporator, rising tube, condenser, and the falling tube. The homogeneous two-phase flow model is used to evaluate the friction pressure drop of the two-phase flow imposed by the available gravitational head through the loop. The saturation temperature dictates both the chip temperature and the condenser heat rejection capacity. Thermodynamic constraints are applied to model the saturation temperature, which also depends upon the local heat transfer coefficient and the two-phase flow patterns inside the condenser. The boiling characteristics of the enhanced structure are used to predict the chip temperature. The model is compared with experimental data for dielectric working fluid PF-5060 and is in general agreement with the observed trends. The degradation of condensation heat transfer coefficient due to diminished vapor convective effects, and the presence of subcooled liquid in the condenser are expected to cause higher thermal resistance at low heat fluxes. The local condensation heat transfer coefficient is a major area of uncertainty.


Author(s):  
R. Sankar Rao ◽  
S. Bhanu Prakash

Heat pipe is the most widely used heat exchanging device in removal of heat from any given system at a faster rate. The thermal characteristics of heat pipe with single and multi-layered screen mesh wicks have been observed with two working fluids water and acetone. Heat pipe of length 250 mm and 12.7 mm outer diameter, made of copper material is used in all the trials of with and without wick structure. A 100 mesh stainless steel screen wire mesh is chosen as wick structure. Experiments were conducted at different heat loads and various inclinations with 100% fill ratio in evaporator. The performance is measured based on total thermal resistance and overall heat transfer coefficient. The heat pipe is found effective at 60o inclination with acetone as a working fluid and with four layered screen mesh wick. Uncertainty in thermal resistance and heat transfer coefficient is calculated for a heat input of 10W at 0 and 60 inclinations.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6886
Author(s):  
Małgorzata Sikora ◽  
Tadeusz Bohdal ◽  
Karolina Formela

This article presents the results obtained from our own experimental investigations on heat exchange and pressure drop during the condensation flow of the HFE 7000 refrigerant in pipe minichannels with an internal diameter of di = 1.2–2.5 mm. The influence of vapor quality x and the mass flux density G on the two-phase flow pressure drops and heat transfer is presented. The tests were performed for the mass flux density range of G = 110–4700 kg/m2s, saturation inlet temperature of Ts = 36–43 °C and heat flux density of q = 1 ÷ 20 kW/m2. The pressure drop characteristics and heat transfer coefficient as a function of the internal diameter of minichannels are illustrated. The results of experimental research on the heat transfer coefficient and two-phase pressure drop are compared with correlations developed by other authors. The best accuracy has a comparison of experimental study with correlation of Rahman-Kariya-Miyara et al. and Mikielewicz et al.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4891
Author(s):  
Magdalena Piasecka ◽  
Kinga Strąk

This paper reports the results of heat transfer during refrigerant flow in rectangular mini-channels at stationary conditions. The impacts of selected parameters on boiling are discussed, i.e., thermal and flow parameters, dimensions and orientation of the channels. Four refrigerants (FC-72, HFE-649, HFE-7000 and HFE-7100) were used as the working fluid. Research was carried out on the experimental set-up with the test section with a single rectangular mini-channel of 180 mm long and with a group of five parallel mini-channels, each 32 mm long. The temperature of the mini-channel’s heated wall was measured by infrared thermography. Local values of the heat transfer coefficient at the contact surface between the fluid and the plate were calculated using the 1D mathematical method. The results are presented as the relationship between the heat transfer coefficient and the distance along the mini-channel length and boiling curves. Two-phase flow patterns are shown. Moreover, the results concerning various refrigerants and the use of modified heater surfaces are discussed. The main factors influencing the heat transfer process were: mini-channel inclination to the horizontal pane (the highest heat transfer coefficient at 270° and 0°), using modified heater surfaces (especially electroerosion texturing and vibration-assisted laser No. 2 texturing) and working fluids (FC-72 and HFE-7000).


Author(s):  
Il Woong Park ◽  
Maria Fernandino ◽  
Carlos Alberto Dorao

Two-phase flow instabilities have been studied during the past decades. Pressure drop oscillation (PDO) shows a relatively larger amplitude oscillation compared with other instabilities. This oscillation typically occurs when the system has compressible volume and operates in a negative slope region of the pressure drop versus flow rate curve. The characteristics of the PDO has been studied experimentally and theoretically. Even though research has been performed for identifying the characteristics of the PDO, how the PDO affects the heat transfer coefficient (HTC) remain unclear. In this study, the heat transfer coefficient is experimentally studied during pressure drop oscillation. The experiment is conducted with a heated horizontal tube with 5 mm inner diameter and 2.0 meters in length, and the R-134a is used a working fluid. For the cases studied, no significant effect of the PDO on the average heat transfer coefficient was observed.


2002 ◽  
Vol 124 (5) ◽  
pp. 881-890 ◽  
Author(s):  
S. I. Haider ◽  
Yogendra K. Joshi ◽  
Wataru Nakayama

This study presents a model for the two-phase flow and heat transfer in the closed loop, two-phase thermosyphon (CLTPT) involving co-current natural circulation. The focus is on CLTPTs for electronics cooling that exhibit complex two-phase flow patterns due to the closed loop geometry and small tube size. The present model is based on mass, momentum, and energy balances in the evaporator, rising tube, condenser, and the falling tube. The homogeneous two-phase flow model is used to evaluate the friction pressure drop of the two-phase flow imposed by the available gravitational head through the loop. The saturation temperature dictates both the heat source (chip) temperature and the condenser heat rejection capacity. Thermodynamic constraints are applied to model the saturation temperature, which also depends upon the local heat transfer coefficient and the two-phase flow patterns inside the condenser. The boiling characteristics of the enhanced structure are used to predict the chip temperature. The model is compared with experimental data for dielectric working fluid PF-5060 and is in general agreement with the observed trends. The degradation of condensation heat transfer coefficient due to diminished vapor convective effects, and the presence of subcooled liquid in the condenser are expected to cause higher thermal resistance at low heat fluxes. The local condensation heat transfer coefficient is a major area of uncertainty.


2017 ◽  
Vol 21 (6 Part A) ◽  
pp. 2481-2489 ◽  
Author(s):  
Babak Aghel ◽  
Masoud Rahimi ◽  
Saeed Almasi

This study investigated the heat transfer characteristics of modified two-phase closed thermosyphon (TPCT) using water as the working fluid. In the modified TPCT, to reduce thermal resistance, a small TPCT was inserted inside the adiabatic section. For both the plain and modified thermosyphons the performances were determined at various heat inputs from 71-960 W. The results showed that the modified TPCT had less temperature difference between the evaporator and condenser sections than the plain one. According to the experimental data, in the modified TPCT, the thermal performance increased up to 20% over that of the unmodified one.


Author(s):  
Li-Jun Fang ◽  
Hong-Peng Song ◽  
Qu-Lan Zhou ◽  
Shi-En Hui ◽  
Tong-Mo Xu

Gas-liquid screen, a novel liquid-gas two-phase flow type, is applied in a scrubber for WFGD. According to the characters of the flow type, heat transfer experiments have been conducted to study the temperature distribution of flue gas in the tower and find the relation between heat transfer coefficient, flue gas and liquid velocity. The results show that whether in concurrent or countercurrent tower the heat transfer coefficient will increase with L/G decreasing at a fixed gas velocity. The optimum position of heat transfer is at the top of the Gas-liquid screen. So multilayer ‘Gas-liquid screen’ could to be arranged to optimize the effect of heat transfer and reduce the industry cost. The formulas of the relation between heat transfer coefficient, flue gas and liquid velocity are gained. These can provide strong foundation for the engineers and the further mass transfer experimental study.


Sign in / Sign up

Export Citation Format

Share Document