Research on pulse stretching of underwater bubbles echo signal of lidar

Author(s):  
Yinbo Zhang ◽  
Jianfeng Sun ◽  
Peng Jiang ◽  
Di Liu ◽  
Xin Zhou
Keyword(s):  
2011 ◽  
Vol 30 (3) ◽  
pp. 564-568
Author(s):  
Xiao-qing Wang ◽  
Ying Yu ◽  
Yong-qiang Chen ◽  
Jiang XIAO ◽  
Min-hui Zhu
Keyword(s):  

2013 ◽  
Vol 756-759 ◽  
pp. 4586-4590
Author(s):  
Jun Gu ◽  
Kun Cai ◽  
Zi Chang Liang

The simulated PM-spectrum fractal sea surfaces and the 3-D near-field distributed model of horn antenna are built, the near-field formulas of KA method are deduced. The near-field scattering coefficient and the Doppler echo signal of rough sea surfaces are calculated, the agreement with measured data proved the correctness and validity of the near-field scattering model.


Electronics ◽  
2018 ◽  
Vol 7 (8) ◽  
pp. 148 ◽  
Author(s):  
Yakun Lv ◽  
Yanhong Wu ◽  
Hongyan Wang ◽  
Lei Qiu ◽  
Jiawei Jiang ◽  
...  

When imaging maneuvering targets with inverse synthetic aperture ladar (ISAL), dispersion and Doppler frequency time-variation exist in the range and cross-range echo signal, respectively. To solve this problem, an ISAL imaging algorithm based on integral cubic phase function-fractional Fourier transform (ICPF-FRFT) is proposed in this paper. The accurate ISAL echo signal model is established for a space maneuvering target that quickly approximates the uniform acceleration motion. On this basis, the chirp rate of the echo signal is quickly estimated by using the ICPF algorithm, which uses the non-uniform fast Fourier transform (NUFFT) method for fast calculations. At the best rotation angle, the range compression is realized by FRFT and the range dispersion is eliminated. After motion compensation, separation imaging of strong and weak scattering points is realized by using ICPF-FRFT and CLEAN technique and the azimuth defocusing problem is solved. The effectiveness of the proposed method is verified by a simulation experiment of an aircraft scattering point model and real data.


2011 ◽  
Vol 403-408 ◽  
pp. 1817-1822
Author(s):  
Xi Feng Zhou ◽  
Xiao Wu ◽  
Qian Gang Guo

The quality of ultrasonic flaw echo signal is the foundation of achieving qualitative and quantitative analysis in the in ultrasonic flaw detection. In practice, the flaw echo signals are often contaminated or even annihilation by random noise. According to the characteristics of ultrasonic flaw echo signal, wavelet packet has more accurate local analysis ability in low frequency and high frequency part. This paper discusses de-noising in ultrasonic signals based on wavelet packet analysis, and proposes an improved threshold approach for de-noising. The results show that: It remarkably raises the signal-to-noise ratio of ultrasonic flaw echo signal and improves the quality of signal with improved wavelet packet threshold.


2011 ◽  
Vol 41 (1) ◽  
pp. 59-67 ◽  
Author(s):  
A. D. Milov ◽  
Yuriy A. Grishin ◽  
S. A. Dzuba ◽  
Yu. D. Tsvetkov

Sign in / Sign up

Export Citation Format

Share Document