Quantitative analysis of flue gas FTIR-spectra employing a new mathematical method to determine the instrumental line shape

Author(s):  
Roman Windpassinger
2017 ◽  
Vol 10 (3) ◽  
pp. 989-997 ◽  
Author(s):  
Youwen Sun ◽  
Mathias Palm ◽  
Christine Weinzierl ◽  
Christof Petri ◽  
Justus Notholt ◽  
...  

Abstract. The TCCON (Total Carbon Column Observing Network) and most NDACC (Network for Detection of Atmospheric Composition Change) sites assume an ideal ILS (instrumental line shape) for analysis of the spectra. In order to adapt the radiant energy received by the detector, an attenuator or different sizes of field stop can be inserted in the light path. These processes may alter the alignment of a high-resolution FTIR (Fourier transform infrared) spectrometer, and may result in bias due to ILS drift. In this paper, we first investigated the sensitivity of the ILS monitoring with respect to application of different kinds of attenuators for ground-based high-resolution FTIR spectrometers within the TCCON and NDACC networks. Both lamp and sun cell measurements were conducted after the insertion of five different attenuators in front of and behind the interferometer. The ILS characteristics derived from lamp and sun spectra are in good agreement. ILSs deduced from all lamp cell measurements were compared. As a result, the disturbances to the ILS of a high-resolution FTIR spectrometer with respect to the insertion of different attenuators at different positions were quantified. A potential strategy to adapt the incident intensity of a detector was finally deduced.


2015 ◽  
Vol 8 (7) ◽  
pp. 3047-3057 ◽  
Author(s):  
M. Frey ◽  
F. Hase ◽  
T. Blumenstock ◽  
J. Groß ◽  
M. Kiel ◽  
...  

Abstract. A comprehensive calibration procedure for mobile, low-resolution, solar-absorption FTIR spectrometers, used for greenhouse gases observations, is developed. These instruments commend themselves for campaign use and deployment at remote sites. The instrumental line shape (ILS) of each spectrometer has been thoroughly characterized by analyzing the shape of H2O signatures in open path spectra. A setup for the external source is suggested and the invariance of derived ILS parameters with regard to chosen path length is demonstrated. The instrumental line shape characteristics of all spectrometers were found to be close to nominal. Side-by-side solar observations before and after a campaign, which involved shipping of all spectrometers to a selected target site and back, are applied for verifying the temporal invariability of instrumental characteristics and for deriving intercalibration factors for XCO2 and XCH4, which take into account residual differences of instrumental characteristics. An excellent level of agreement and stability was found between the different spectrometers: the uncorrected biases in XCO2 and XCH4 are smaller than 0.01 and 0.15 %, respectively, and the drifts are smaller than 0.005 and 0.035 %. As an additional sensitive demonstration of the instrumental performance we show the excellent agreement of ground pressure values obtained from the total column measurements of O2 and barometric records. We find a calibration factor of 0.9700 for the spectroscopic measurements in comparison to the barometric records and a very small scatter between the individual spectrometers (0.02 %). As a final calibration step, using a co-located TCCON (Total Carbon Column Observation Network) spectrometer as a reference, a common scaling factor has been derived for the XCO2 and XCH4 products, which ensures that the records are traceable to the WMO in situ scale.


2020 ◽  
Vol 88 (3) ◽  
pp. 35
Author(s):  
Endjang Prebawa Tejamukti ◽  
Widiastuti Setyaningsih ◽  
Irnawati ◽  
Budiman Yasir ◽  
Gemini Alam ◽  
...  

Mangosteen, or Garcinia mangostana L., has merged as an emerging fruit to be investigated due to its active compounds, especially xanthone derivatives such as α -mangostin (AM), γ-mangostin (GM), and gartanin (GT). These compounds had been reported to exert some pharmacological activities, such as antioxidant and anti-inflammatory, therefore, the development of an analytical method capable of quantifying these compounds should be investigated. The aim of this study was to determine the correlation between FTIR spectra and HPLC chromatogram, combined with chemometrics for quantitative analysis of ethanolic extract of mangosteen. The ethanolic extract of mangosteen pericarp was prepared using the maceration technique, and the obtained extract was subjected to measurement using instruments of FTIR spectrophotometer at wavenumbers of 4000–650 cm−1 and HPLC, using a PDA detector at 281 nm. The data acquired were subjected to chemometrics analysis of partial least square (PLS) and principal component regression (PCR). The result showed that the wavenumber regions of 3700–2700 cm−1 offered a reliable method for quantitative analysis of GM with coefficient of determination (R2) 0.9573 in calibration and 0.8134 in validation models, along with RMSEC value of 0.0487% and RMSEP value 0.120%. FTIR spectra using the second derivatives at wavenumber 3700–663 cm−1 with coefficient of determination (R2) >0.99 in calibration and validation models, along with the lowest RMSEC value and RMSEP value, were used for quantitative analysis of GT and AM, respectively. It can be concluded that FTIR spectra combined with multivariate are accurate and precise for the analysis of xanthones.


2018 ◽  
Vol 180 ◽  
pp. 02005
Author(s):  
Ondřej Bartoš ◽  
Jan Havlík ◽  
František Hrdlička

The aim of the paper is to introduce the study of condensation processes in the wet stack. Because of the high cost of reheating (due to the loss of useful heat of flue gases), wet stacks are being considered for new or retrofit applications of wet flue gas desulfurization (FGD) systems around the word. Wet stacks, in contrast to classical chimneys where flue gases are heated up to avoid any condensation, works with wet flue gases and condensation is welcome. The study provides a quantitative analysis of the condensation.


2000 ◽  
Vol 39 (33) ◽  
pp. 6230 ◽  
Author(s):  
Mikko Ahro ◽  
Jyrki Kauppinen ◽  
Ilkka Salomaa

2012 ◽  
Vol 5 (11) ◽  
pp. 2917-2931 ◽  
Author(s):  
O. E. García ◽  
M. Schneider ◽  
A. Redondas ◽  
Y. González ◽  
F. Hase ◽  
...  

Abstract. This study investigates the long-term evolution of subtropical ozone profile time series (1999–2010) obtained from ground-based FTIR (Fourier Transform InfraRed) spectrometry at the Izaña Observatory ozone super-site. Different ozone retrieval strategies are examined, analysing the influence of an additional temperature retrieval and different constraints. The theoretical assessment reveals that the FTIR system is able to resolve four independent ozone layers with a precision of better than 6% in the troposphere and of better than 3% in the lower, middle and upper stratosphere. This total error includes the smoothing error, which dominates the random error budget. Furthermore, we estimate that the measurement noise as well as uncertainties in the applied atmospheric temperature profiles and instrumental line shape are leading error sources. We show that a simultaneous temperature retrieval can significantly reduce the total random errors and that a regular determination of the instrumental line shape is important for producing a consistent long-term dataset. These theoretical precision estimates are empirically confirmed by daily intercomparisons with Electro Chemical Cell (ECC) sonde profiles. In order to empirically document the long-term stability of the FTIR ozone profile data we compare the linear trends and seasonal cycles as obtained from the FTIR and ECC time series. Concerning seasonality, in winter both techniques observe stratospheric ozone profiles that are typical middle latitude profiles (low tropopause, low ozone maximum concentrations) and in summer/autumn profiles that are typical tropical profiles (high tropopause, high maximum concentrations). The linear trends estimated from the FTIR and the ECC datasets agree within their error bars. For the FTIR time series, we observe a significant negative trend in the upper troposphere/lower stratosphere of about −0.2% yr−1 and a significant positive trend in the middle and upper stratosphere of about +0.3% yr−1 and +0.4% yr−1, respectively. Identifying such small trends is a difficult task for any measurement technique. In this context, super-sites applying different techniques are very important for the detection of reliable ozone trends.