Position-sensing transition-edge sensors for large-field high-energy-resolution x-ray imaging spectroscopy

Author(s):  
Enectali Figueroa-Feliciano ◽  
Caroline K. Stahle ◽  
Fred M. Finkbeiner ◽  
Mary J. Li ◽  
Mark A. Lindeman ◽  
...  
2021 ◽  
Vol 92 (1) ◽  
pp. 013103
Author(s):  
Shinya Yamada ◽  
Yuto Ichinohe ◽  
Hideyuki Tatsuno ◽  
Ryota Hayakawa ◽  
Hirotaka Suda ◽  
...  

2017 ◽  
Vol 36 (9) ◽  
pp. 1784-1795 ◽  
Author(s):  
Silvia Pani ◽  
Sarene C. Saifuddin ◽  
Filipa I.M. Ferreira ◽  
Nicholas Henthorn ◽  
Paul Seller ◽  
...  

2003 ◽  
Vol 17 (04n06) ◽  
pp. 948-952 ◽  
Author(s):  
C. GANDINI ◽  
V. LACQUANITI ◽  
E. MONTICONE ◽  
C. PORTESI ◽  
M. RAJTERI ◽  
...  

Recently transition-edge sensors (TES) have obtained an increasing interest as light detectors due to their high energy resolution and broadband response. Titanium (Ti), with transition temperature up to 0.5 K, is among the suitable materials for TES application. In this work we investigate Ti films obtained from two materials of different purity deposited by e-gun on silicon nitride. Films with different thickness and deposition substrate temperature have been measured. Critical temperatures, electrical resistivities and structural properties obtained from x-ray are related to each other.


2009 ◽  
Author(s):  
E. Figueroa-Feliciano ◽  
J. S. Adams ◽  
R. Baker ◽  
S. R. Bandler ◽  
T. A. DeLaney ◽  
...  

2018 ◽  
Vol 65 (7) ◽  
pp. 1408-1415 ◽  
Author(s):  
D. Baudin ◽  
S. Dubos ◽  
O. Gevin ◽  
O. Limousin ◽  
D. Maier ◽  
...  

2014 ◽  
Vol 617 ◽  
pp. 233-236
Author(s):  
Keiichi Tanaka ◽  
Masataka Ohgaki ◽  
Hidekazu Suzuki ◽  
Masakatsu Hasuda ◽  
Masato Yano ◽  
...  

Transition Edge Sensor (TES) is an energy dispersive X-ray detecting system with high energy resolution. The energy resolution of this system depends on the steepness of superconducting transition curve from normal to superconducting state, heat capacitance and the operating temperature. The TES is based on the dilution refrigerator cooled by about 100 mK. The energy resolution is calculated about 1-2 eV for the detector with maximum detecting energy as 10 eV. The energy resolution also depends on the superconducting current flowing through the TES device because the superconducting current is affected by the temperature stability of the refrigerator. The fluctuation of the superconducting current means the fluctuation of the X-ray spectrum peak center. We have developed the sensitivity correction system to stabilize the peak center of the X-ray spectrum. The peak center of X-ray spectrum correlates with heater power to keep the base temperature of TES device at a constant temperature. The peak center of X-ray spectrum is calibrated by monitoring the heater power at constant time interval using the correlation curve between the peak center of X-ray spectrum and heater power.


2017 ◽  
Vol 139 (49) ◽  
pp. 18024-18033 ◽  
Author(s):  
Rebeca G. Castillo ◽  
Rahul Banerjee ◽  
Caleb J. Allpress ◽  
Gregory T. Rohde ◽  
Eckhard Bill ◽  
...  

2015 ◽  
Vol 112 (52) ◽  
pp. 15803-15808 ◽  
Author(s):  
Ofer Hirsch ◽  
Kristina O. Kvashnina ◽  
Li Luo ◽  
Martin J. Süess ◽  
Pieter Glatzel ◽  
...  

The lanthanum-based materials, due to their layered structure and f-electron configuration, are relevant for electrochemical application. Particularly, La2O2CO3 shows a prominent chemoresistive response to CO2. However, surprisingly less is known about its atomic and electronic structure and electrochemically significant sites and therefore, its structure–functions relationships have yet to be established. Here we determine the position of the different constituents within the unit cell of monoclinic La2O2CO3 and use this information to interpret in situ high-energy resolution fluorescence-detected (HERFD) X-ray absorption near-edge structure (XANES) and valence-to-core X-ray emission spectroscopy (vtc XES). Compared with La(OH)3 or previously known hexagonal La2O2CO3 structures, La in the monoclinic unit cell has a much lower number of neighboring oxygen atoms, which is manifested in the whiteline broadening in XANES spectra. Such a superior sensitivity to subtle changes is given by HERFD method, which is essential for in situ studying of the interaction with CO2. Here, we study La2O2CO3-based sensors in real operando conditions at 250 °C in the presence of oxygen and water vapors. We identify that the distribution of unoccupied La d-states and occupied O p- and La d-states changes during CO2 chemoresistive sensing of La2O2CO3. The correlation between these spectroscopic findings with electrical resistance measurements leads to a more comprehensive understanding of the selective adsorption at La site and may enable the design of new materials for CO2 electrochemical applications.


Sign in / Sign up

Export Citation Format

Share Document