Advances in analytical techniques for neutron capture therapy: Thin layer chromatography matrix and track etch thin layer chromatography methods for boron-10 analysis

1987 ◽  
Vol 14 (5) ◽  
pp. 818-824 ◽  
Author(s):  
Jacalyn M. Schremmer ◽  
Denise J. Noonan
1977 ◽  
Vol 1977 (1) ◽  
pp. 189-191
Author(s):  
James C. Clow

ABSTRACT The Federal Water Pollution Control Act (FWPCA), as amended in 1972, tasks the Coast Guard with development of “procedures and techniques to be employed in identifying…. oil and hazardous substances….” In carrying out this portion of the service's environmental mandate, the Coast Guard Research and Development Center has developed first generation laboratory and field systems for the forensic identification and classification of oil spills. The laboratory system utilizes four independent analytical techniques (infrared and fluorescence spectroscopy, gas and thin-layer chromatography) to match spill samples with suspected sources, while the field system utilizes two analytical techniques (fluorescence spectroscopy and thin-layer chromatography). The field system is designed to give each Captain of the Port or Marine Safety Office the capability to rapidly identify the source of the majority of oil spills, or in more difficult cases to provide sufficient information to justify the collection of additional samples for more detailed analysis by the laboratory system.


2015 ◽  
Vol 20 (2) ◽  
pp. 71-75
Author(s):  
Mareta Mukharbekovna Ibragimova ◽  
Latif Tulaganovich Ikramov

Objective: An increasing numbers of cases of poisonings by glimepiride, either attempted suicide or accidental, combined with the absence of reliable methods for the detection and quantitation of glimepiride in biological matrices is the basis for the need for the development of new analytical techniques for forensic analysis.Materials and Methods: Analyses were performed using drug- free biological fluids (whole blood and urine). Specimens were spiked with chromatographically pure glimepiride. After hydrolysis with diluted hydrochloric acid at 50-60 °C for 15-20 min and a double extraction into chloroform, glimepiride was identified by thin-layer chromatography. Standard solution of glimepiride (1 mg/mL) and Sorbfil chromatographic plates were used for thin-layer chromatography. The thin-layer chromatography studies showed that the best mobile phase was chloroform:acetone (9:1), Rf value of glimepiride in five examinations was 0.37±0.02. Visualization of glimepiride was achieved byspraying with Dragendorff’s, Bushard’s, or diphenylcarbazone-chloroform solution followed by mercuric sulphate. The limit of detection of pure glimepiride by thin-layer chromatography was 0.5 p/mL, 1.5 p g/mL in whole blood and 1.0 p g/mL in urine. For spectrophotometric determinations of glimepiride, a UV/VIS spectrophotometer with 1 cm matches quartz cell was used. Standard solutions of glimepiride in ethanol were prepared at concentrations of 1-50 p g/mL and scanned in full-scan mode between 200-400 nm.Results and Conclusion: The wavelength maxima for glimepiride was found to be 227 nm with molar absorptivity of 3.2685x10 4 l/mol/cm. Beer’s law was obeyed in the concentration range of 2-40 p g/mL. The limit of detection and limit of quantification were found to be 0.97 p g/mL and 2.70 p g/mL, respectively. The results have been successfully applied in blood of patients after oral administration and on postmortem blood in an overdose death.Keywords: Glimepiride, Thin-layer chromatography, Spectrophotometry.


2015 ◽  
Vol 1 (3) ◽  
pp. 114 ◽  
Author(s):  
Bhadresh V Savaj ◽  
Ashutoshkumar Patidar ◽  
Hasumati A Raj

Hydrochlorothiazide is chemically 6-chloro-1, 1-dioxo-3, 4-dihydro-2H-1, 2, 4-benzothiadiazine-7-sulfonamide. Hydrochlorothiazide is a diuretic drug used for treatment of high blood pressure(hypertension) and accumulation of fluid (edema). It works by blocking salt and fluid reabsorption from the urine in the kidneys, causing increased urine output (dieresis). Hydrochlorothiazide is used to treat excessive fluid accumulation and swelling (edema) of the body caused byheart failure, cirrhosis, chronickidney failure, corticosteroid medications, and nephrotic syndrome. It can be used alone or in conjunction with otherblood pressure lowering medicationstotreat high blood pressure.This review focuses on the recent developments in analytical techniques for estimation of Hydrochlorothiazide alone or in combinations with other drugs in various biological media like human plasma and urine. This review will critically examine the (a) sample pretreatment method such as solid phase extraction (SPE), (b) separation methods such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC), ultra performance liquid chromatography (UPLC), high performance thin layer chromatography (HPTLC), liquid chromatography coupled to tandem mass spectrometry (LC-MS) and capillary electrophoresis (CE), (c) other methods such as spectrophotometry, diffuse reflectance near infrared spectroscopy and electrochemical methods.


Author(s):  
H. R. Bolliger ◽  
M. Brenner ◽  
H. Gänshirt ◽  
Helmut K. Mangold ◽  
H. Seiler ◽  
...  

1969 ◽  
Vol 61 (4) ◽  
pp. 641-648 ◽  
Author(s):  
Leon J. Sholiton ◽  
Emile E. Werk

ABSTRACT Rat and bovine brain have been incubated with testosterone-4-14C under standard conditions. With use of paper chromatography, the extracted metabolites were noted to fall into less-polar, iso-polar, and more polar fractions. The components of the less-polar fraction were separated by acetylation and thin-layer chromatography and the major end-products identified by recrystallization to constant specific activity or constant 3H/14C ratios. Androst-4-enedione and 5α-dihydrotestosterone were formed consistently under the conditions utilized. Trace amounts of other less-polar metabolites were noted occasionally.


Sign in / Sign up

Export Citation Format

Share Document