The effect of hearing aid signal processing on speech intelligibility in a realistic virtual sound environment

2020 ◽  
Vol 148 (4) ◽  
pp. 2721-2721
Author(s):  
Naim Mansour ◽  
Marton Marschall ◽  
Tobias May ◽  
Adam Westermann ◽  
Torsten Dau
2022 ◽  
Vol 151 (1) ◽  
pp. 232-241
Author(s):  
Naim Mansour ◽  
Marton Marschall ◽  
Adam Westermann ◽  
Tobias May ◽  
Torsten Dau

1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


1990 ◽  
Vol 88 (S1) ◽  
pp. S175-S175
Author(s):  
Michael Nilsson ◽  
Jean Sullivan ◽  
Sigfrid D. Soli

2005 ◽  
Vol 16 (08) ◽  
pp. 600-613 ◽  
Author(s):  
Jill E. Preminger ◽  
Ryan Carpenter ◽  
Craig H. Ziegler

Using the threshold equalizing noise (TEN) test, 49 subjects with at least two pure-tone thresholds per ear greater than 50 dB HL and none greater than 80 dB HL were evaluated for the presence or absence of dead regions. The purpose of this study was to (1) assess the prevalence of cochlear dead regions in this clinical population, (2) measure whether listeners with dead regions performed differently than listeners without dead regions on a speech intelligibility in noise test, and (3) determine whether cochlear dead regions are associated with reduced subjective hearing aid performance. The results showed that (1) twenty-nine percent of the subjects tested positive for dead regions, (2) listeners with dead regions had poorer sentence understanding in noise than listeners without dead regions and (3) listeners with dead regions perceived poorer subjective hearing aid performance in listening environments with reverberation or background noise as compared to those without dead regions.


2020 ◽  
Vol 24 ◽  
pp. 233121652097034
Author(s):  
Florian Langner ◽  
Andreas Büchner ◽  
Waldo Nogueira

Cochlear implant (CI) sound processing typically uses a front-end automatic gain control (AGC), reducing the acoustic dynamic range (DR) to control the output level and protect the signal processing against large amplitude changes. It can also introduce distortions into the signal and does not allow a direct mapping between acoustic input and electric output. For speech in noise, a reduction in DR can result in lower speech intelligibility due to compressed modulations of speech. This study proposes to implement a CI signal processing scheme consisting of a full acoustic DR with adaptive properties to improve the signal-to-noise ratio and overall speech intelligibility. Measurements based on the Short-Time Objective Intelligibility measure and an electrodogram analysis, as well as behavioral tests in up to 10 CI users, were used to compare performance with a single-channel, dual-loop, front-end AGC and with an adaptive back-end multiband dynamic compensation system (Voice Guard [VG]). Speech intelligibility in quiet and at a +10 dB signal-to-noise ratio was assessed with the Hochmair–Schulz–Moser sentence test. A logatome discrimination task with different consonants was performed in quiet. Speech intelligibility was significantly higher in quiet for VG than for AGC, but intelligibility was similar in noise. Participants obtained significantly better scores with VG than AGC in the logatome discrimination task. The objective measurements predicted significantly better performance estimates for VG. Overall, a dynamic compensation system can outperform a single-stage compression (AGC + linear compression) for speech perception in quiet.


2016 ◽  
Vol 27 (09) ◽  
pp. 732-749 ◽  
Author(s):  
Gabriel Aldaz ◽  
Sunil Puria ◽  
Larry J. Leifer

Background: Previous research has shown that hearing aid wearers can successfully self-train their instruments’ gain-frequency response and compression parameters in everyday situations. Combining hearing aids with a smartphone introduces additional computing power, memory, and a graphical user interface that may enable greater setting personalization. To explore the benefits of self-training with a smartphone-based hearing system, a parameter space was chosen with four possible combinations of microphone mode (omnidirectional and directional) and noise reduction state (active and off). The baseline for comparison was the “untrained system,” that is, the manufacturer’s algorithm for automatically selecting microphone mode and noise reduction state based on acoustic environment. The “trained system” first learned each individual’s preferences, self-entered via a smartphone in real-world situations, to build a trained model. The system then predicted the optimal setting (among available choices) using an inference engine, which considered the trained model and current context (e.g., sound environment, location, and time). Purpose: To develop a smartphone-based prototype hearing system that can be trained to learn preferred user settings. Determine whether user study participants showed a preference for trained over untrained system settings. Research Design: An experimental within-participants study. Participants used a prototype hearing system—comprising two hearing aids, Android smartphone, and body-worn gateway device—for ˜6 weeks. Study Sample: Sixteen adults with mild-to-moderate sensorineural hearing loss (HL) (ten males, six females; mean age = 55.5 yr). Fifteen had ≥6 mo of experience wearing hearing aids, and 14 had previous experience using smartphones. Intervention: Participants were fitted and instructed to perform daily comparisons of settings (“listening evaluations”) through a smartphone-based software application called Hearing Aid Learning and Inference Controller (HALIC). In the four-week-long training phase, HALIC recorded individual listening preferences along with sensor data from the smartphone—including environmental sound classification, sound level, and location—to build trained models. In the subsequent two-week-long validation phase, participants performed blinded listening evaluations comparing settings predicted by the trained system (“trained settings”) to those suggested by the hearing aids’ untrained system (“untrained settings”). Data Collection and Analysis: We analyzed data collected on the smartphone and hearing aids during the study. We also obtained audiometric and demographic information. Results: Overall, the 15 participants with valid data significantly preferred trained settings to untrained settings (paired-samples t test). Seven participants had a significant preference for trained settings, while one had a significant preference for untrained settings (binomial test). The remaining seven participants had nonsignificant preferences. Pooling data across participants, the proportion of times that each setting was chosen in a given environmental sound class was on average very similar. However, breaking down the data by participant revealed strong and idiosyncratic individual preferences. Fourteen participants reported positive feelings of clarity, competence, and mastery when training via HALIC. Conclusions: The obtained data, as well as subjective participant feedback, indicate that smartphones could become viable tools to train hearing aids. Individuals who are tech savvy and have milder HL seem well suited to take advantages of the benefits offered by training with a smartphone.


2016 ◽  
Vol 27 (03) ◽  
pp. 219-236 ◽  
Author(s):  
Susan Scollie ◽  
Danielle Glista ◽  
Julie Seto ◽  
Andrea Dunn ◽  
Brittany Schuett ◽  
...  

Background: Although guidelines for fitting hearing aids for children are well developed and have strong basis in evidence, specific protocols for fitting and verifying technologies can supplement such guidelines. One such technology is frequency-lowering signal processing. Children require access to a broad bandwidth of speech to detect and use all phonemes including female /s/. When access through conventional amplification is not possible, the use of frequency-lowering signal processing may be considered as a means to overcome limitations. Fitting and verification protocols are needed to better define candidacy determination and options for assessing and fine tuning frequency-lowering signal processing for individuals. Purpose: This work aims to (1) describe a set of calibrated phonemes that can be used to characterize the variation in different brands of frequency-lowering processors in hearing aids and the verification with these signals and (2) determine whether verification with these signal are predictive of perceptual changes associated with changes in the strength of frequency-lowering signal processing. Finally, we aimed to develop a fitting protocol for use in pediatric clinical practice. Study Sample: Study 1 used a sample of six hearing aids spanning four types of frequency lowering algorithms for an electroacoustic evaluation. Study 2 included 21 adults who had hearing loss (mean age 66 yr). Data Collection and Analysis: Simulated fricatives were designed to mimic the level and frequency shape of female fricatives extracted from two sources of speech. These signals were used to verify the frequency-lowering effects of four distinct types of frequency-lowering signal processors available in commercial hearing aids, and verification measures were compared to extracted fricatives made in a reference system. In a second study, the simulated fricatives were used within a probe microphone measurement system to verify a wide range of frequency compression settings in a commercial hearing aid, and 27 adult listeners were tested at each setting. The relation between the hearing aid verification measures and the listener’s ability to detect and discriminate between fricatives was examined. Results: Verification measures made with the simulated fricatives agreed to within 4 dB, on average, and tended to mimic the frequency response shape of fricatives presented in a running speech context. Some processors showed a greater aided response level for fricatives in running speech than fricatives presented in isolation. Results with listeners indicated that verified settings that provided a positive sensation level of /s/ and that maximized the frequency difference between /s/ and /∫/ tended to have the best performance. Conclusions: Frequency-lowering signal processors have measureable effects on the high-frequency fricative content of speech, particularly female /s/. It is possible to measure these effects either with a simple strategy that presents an isolated simulated fricative and measures the aided frequency response or with a more complex system that extracts fricatives from running speech. For some processors, a more accurate result may be achieved with a running speech system. In listeners, the aided frequency location and sensation level of fricatives may be helpful in predicting whether a specific hearing aid fitting, with or without frequency-lowering, will support access to the fricatives of speech.


2021 ◽  
Vol 149 (4) ◽  
pp. 2791-2801
Author(s):  
Naim Mansour ◽  
Marton Marschall ◽  
Tobias May ◽  
Adam Westermann ◽  
Torsten Dau

Sign in / Sign up

Export Citation Format

Share Document