Development of a speech intelligibility test for hearing aid research

1990 ◽  
Vol 88 (S1) ◽  
pp. S175-S175
Author(s):  
Michael Nilsson ◽  
Jean Sullivan ◽  
Sigfrid D. Soli
1966 ◽  
Vol 9 (2) ◽  
pp. 253-258 ◽  
Author(s):  
James Jerger ◽  
Carolyn Malmquist ◽  
Charles Speaks

A sentence intelligibility test and three monosyllabic word intelligibility tests, recorded through three hearing aids, were presented to 36 subjects with diverse types of hearing loss. Although hearing aids were rank ordered meaningfully on the sentence intelligibility test-in inverse proportion to the harmonic distortion-performance differences were not systematically reflected in the monosyllabic word test results.


1991 ◽  
Vol 89 (4B) ◽  
pp. 1960-1960 ◽  
Author(s):  
Michael J. Nilsson ◽  
Jean Sullivan ◽  
Sigfrid D. Soli

1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


2005 ◽  
Vol 16 (08) ◽  
pp. 600-613 ◽  
Author(s):  
Jill E. Preminger ◽  
Ryan Carpenter ◽  
Craig H. Ziegler

Using the threshold equalizing noise (TEN) test, 49 subjects with at least two pure-tone thresholds per ear greater than 50 dB HL and none greater than 80 dB HL were evaluated for the presence or absence of dead regions. The purpose of this study was to (1) assess the prevalence of cochlear dead regions in this clinical population, (2) measure whether listeners with dead regions performed differently than listeners without dead regions on a speech intelligibility in noise test, and (3) determine whether cochlear dead regions are associated with reduced subjective hearing aid performance. The results showed that (1) twenty-nine percent of the subjects tested positive for dead regions, (2) listeners with dead regions had poorer sentence understanding in noise than listeners without dead regions and (3) listeners with dead regions perceived poorer subjective hearing aid performance in listening environments with reverberation or background noise as compared to those without dead regions.


Revista CEFAC ◽  
2010 ◽  
Vol 12 (4) ◽  
pp. 662-670 ◽  
Author(s):  
Tatiane Maria Pelitero ◽  
Alessandra Kerli da Silva Manfredi ◽  
Andrea Pires Corrêa Schneck

OBJETIVO: comparar o desempenho na Avaliação Simplificada do Processamento Auditivo (ASPA) e no Pediatric Speech Intelligibility Test (PSI), de crianças com alteração de Aprendizagem da Leitura e Escrita e sem este tipo de alteração. MÉTODOS: participaram da pesquisa 28 crianças na faixa etária de 8 a 12 anos, do sexo masculino e feminino. Os participantes foram submetidos ao Teste de Desempenho Escolar (TDE) para a categorização dos grupos de estudo e controle, e, para avaliação das habilidades auditivas foram aplicados a ASPA e o Teste PSI. RESULTADOS: não foi observada associação estatisticamente significante entre o desempenho nos testes de Processamento Auditivo (PA) e o grupo com dificuldades de aprendizagem, apesar de ter sido verificada maior frequência de alterações no grupo de estudo em relação ao grupo controle, em todos os testes. Na ASPA, o teste em que se observou maior número de alterações foi o Teste de Memória Sequencial Verbal, contudo, o Teste de Memória Sequencial Não-verbal foi o que mostrou maior diferença entre os grupos. CONCLUSÃO: Não foram encontradas diferenças estatisticamente significantes no desempenho na Avaliação Simplificada do Processamento Auditivo (ASPA) e no Pediatric Speech Intelligibility Test (PSI), das crianças com alteração de Aprendizagem da Leitura e Escrita e sem alteração.


2020 ◽  
Vol 5 (1) ◽  
pp. 36-39
Author(s):  
Mariya Yu. Boboshko ◽  
Irina P. Berdnikova ◽  
Natalya V. Maltzeva

Objectives -to determine the normative data of sentence speech intelligibility in a free sound field and to estimate the applicability of the Russian Matrix Sentence test (RuMatrix) for assessment of the hearing aid fitting benefit. Material and methods. 10 people with normal hearing and 28 users of hearing aids with moderate to severe sensorineural hearing loss were involved in the study. RuMatrix test both in quiet and in noise was performed in a free sound field. All patients filled in the COSI questionnaire. Results. The hearing impaired patients were divided into two subgroups: the 1st with high and the 2nd with low hearing aid benefit, according to the COSI questionnaire. In the 1st subgroup, the threshold for the sentence intelligibility in quiet was 34.9 ± 6.4 dB SPL, and in noise -3.3 ± 1.4 dB SNR, in the 2nd subgroup 41.7 ± 11.5 dB SPL and 0.15 ± 3.45 dB SNR, respectively. The significant difference between the data of both subgroups and the norm was registered (p


1980 ◽  
Vol 89 (5_suppl) ◽  
pp. 79-83
Author(s):  
Richard Lippmann

Following the Harvard master hearing aid study in 1947 there was little research on linear amplification. Recently, however, there have been a number of studies designed to determine the relationship between the frequency-gain characteristic of a hearing aid and speech intelligibility for persons with sensorineural hearing loss. These studies have demonstrated that a frequency-gain characteristic that rises at a rate of 6 dB/octave, as suggested by the Harvard study, is not optimal. They have also demonstrated that high-frequency emphasis of 10–40 dB above 500–1000 Hz is beneficial. Most importantly, they have demonstrated that hearing aids as they are presently being fit do not provide maximum speech intelligibility. Percent word correct scores obtained with the best frequency-gain characteristics tested in various studies have been found to be 9 to 19 percentage points higher than scores obtained with commercial aids owned by subjects. This increase in scores is equivalent to an increase in signal-to-noise ratio of 10 to 20 dB. This is a significant increase which could allow impaired listeners to communicate in many situations where they presently cannot. These results demonstrate the need for further research on linear amplification aimed at developing practical suggestions for fitting hearing aids.


1990 ◽  
Vol 33 (4) ◽  
pp. 676-689 ◽  
Author(s):  
David A. Fabry ◽  
Dianne J. Van Tasell

The Articulation Index (AI) was used to evaluate an “adaptive frequency response” (AFR) hearing aid with amplification characteristics that automatically change to become more high-pass with increasing levels of background noise. Speech intelligibility ratings of connected discourse by normal-hearing subjects were predicted well by an empirically derived AI transfer function. That transfer function was used to predict aided speech intelligibility ratings by 12 hearing-impaired subjects wearing a master hearing aid with the Argosy Manhattan Circuit enabled (AFR-on) or disabled (AFR-off). For all subjects, the AI predicted no improvements in speech intelligibility for the AFR-on versus AFR-off condition, and no significant improvements in rated intelligibility were observed. The ability of the AI to predict aided speech intelligibility varied across subjects. However, ratings from every hearing-impaired subject were related monotonically to AI. Therefore, AI calculations may be used to predict relative—but not absolute—levels of speech intelligibility produced under different amplification conditions.