scholarly journals The Test–Retest Reliability of Bilateral and Unilateral Force Plate–Derived Parameters of the Countermovement Push-Up in Elite Boxers

2020 ◽  
pp. 1-5
Author(s):  
Gemma N. Parry ◽  
Lee C. Herrington ◽  
Ian G. Horsley ◽  
Ian Gatt

Context: Maximal power describes the ability to immediately produce power with the maximal velocity at the point of release, impact, and/or take off—the greater an athlete’s ability to produce maximal power, the greater the improvement of athletic performance. In reference to boxing performance, regular consistent production of high muscular power during punching is considered an essential prerequisite. Despite the importance of upper limb power to athletic performance, presently, there is no gold standard test for upper limb force development performance. Objective: To investigate the test–retest reliability of the force plate–derived measures of countermovement push-up in elite boxers. Design: Test–retest design. Setting: High Performance Olympic Training Center. Participants: Eighteen elite Olympic boxers (age = 23 [3] y; height = 1.68 [0.39] m; body mass = 70.0 [17] kg). Intervention: Participants performed 5 repetitions of countermovement push-up trials on FD4000 Forcedeck dual force platforms on 2 separate test occasions 7 days apart. Main Outcome Measures: Peak force, mean force, flight time, rate of force development, impulse, and vertical stiffness of the bilateral and unilateral limbs from the force–time curve. Results: No significant differences between the 2 trial occasions for any of the derived bilateral or unilateral performance measures. Intraclass correlation coefficients indicated moderate to high reliability for performance parameters (intraclass correlation coefficients = .68–.98) and low coefficient of variation (3%–10%) apart from vertical stiffness (coefficient of variation = 16.5%–25%). Mean force demonstrated the greatest reliability (coefficient of variation = 3%). In contrast, no significant differences (P < .001) were noted between left and right limbs (P = .005–.791), or between orthodox or southpaw boxing styles (P = .19–.95). Conclusion: Force platform–derived kinetic bilateral and unilateral parameters of countermovement push-up are reliable measures of upper limb power performance in elite-level boxers; results suggest unilateral differences within the bilateral condition are not the norm for an elite boxing cohort.

2020 ◽  
Vol 29 (3) ◽  
pp. 381-383 ◽  
Author(s):  
Gemma N. Parry ◽  
Lee C. Herrington ◽  
Ian G. Horsley

Context: Muscular power output of the upper limb is a key aspect of athletic and sporting performance. Maximal power describes the ability to immediately produce power with maximal velocity at the point of release, impact, or takeoff, with research highlighting that the greater an athlete’s ability to produce maximal power, the greater the improvement in athletic performance. Despite the importance of upper-limb power for athletic performance, there is presently no gold-standard test for upper-limb force development performance. Objective: The aim of this study was to investigate the test–retest reliability of force plate–derived measures of the countermovement push-up in active males. Design: Test–retest design. Setting: Controlled laboratory. Participants: Physically active college athletes (age 24 [3] y, height 1.79 [0.08] m, body mass 81.7 [9.9] kg). Intervention: Subjects performed 3 repetitions of maximal effort countermovement push-up trials on Kistler force plates on 2 separate test occasions 7 days apart. Main Outcome Measures: Peak force, mean force, flight time, rate of force development, and impulse were analyzed from the force–time curve. Results: No significant differences between the 2 trial occasions were observed for any of the derived performance measures. Intraclass correlation coefficient and within-subject coefficient of variation calculations indicated performance measures to have moderate to very high reliability (intraclass correlation coefficient = .88–.98), coefficient of variation = 5.5%–14.1%). Smallest detectable difference for peak force (7.5%), mean force (8.6%), and rate of force development (11.2%) were small to moderate. Conclusion: Force platform–derived kinetic parameters of countermovement push-up are reliable measurements of power in college-level athletes.


2021 ◽  
pp. 1-4
Author(s):  
Jamon Couch ◽  
Marc Sayers ◽  
Tania Pizzari

Context: An imbalance between shoulder internal rotation (IR) and external rotation (ER) strength in athletes is proposed to increase the risk of sustaining a shoulder injury. Hand-held (HHD) and externally fixed dynamometry are reliable forms of assessing shoulder IR and ER strength. A new externally fixed device with an attachable fixed upper-limb mold (The ForceFrame) exists; however, its reliability in measuring shoulder strength is yet to be investigated. Objective: To determine the test–retest reliability of the ForceFrame, with and without the fixed upper-limb mold, in the assessment of shoulder IR and ER strength, as compared with HHD. Design: Test–retest reliability study. Setting: Laboratory, clinical. Participants: Twenty-two healthy and active individuals were recruited from the university community and a private physiotherapy practice. Main Outcome Measures: Maximal isometric shoulder IR and ER strength was measured using the ForceFrame and traditional HHD in neutral and at 90° shoulder abduction. Mean (SD) strength measures were calculated. Test–retest reliability was analyzed using intraclass correlation coefficients (3, 1). The SEM and minimal detectable change were calculated. Results: Good to excellent test–retest reliability was found for all shoulder strength tests across Hand-held dynamometry (HHD) and externally fixed dynamometry (EFD) are reliable forms (intraclass correlation coefficients [3, 1] = .854–.916). The minimal detectable changes ranged between 25.61 and 41.84 N across tests. Test–retest reliability was not affected by the dynamometer or testing position. Conclusions: The results from this study indicate that both the ForceFrame and HHD are suitable for measuring shoulder strength in clinical practice. The use of the fixed upper-limb mold with the ForceFrame does not improve reliability.


Author(s):  
Michael J. Duncan ◽  
Darren Richardson ◽  
Rhys Morris ◽  
Emma Eyre ◽  
Neil D. Clarke

The present study examined the test–retest reliability of the Ghent University dribbling test and short dribble test in a pediatric population. Fifty-four boys aged 9–14 years (mean ± SD = 11 ± 2 years) undertook the Ghent University and dribbling tests on two occasions separated by 2 weeks. Intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement were conducted for each test. Intraclass correlation coefficients and coefficient of variation indicated good to excellent reliability, and relatively small variability for both dribbling tests. The 95% limits of agreement indicated relatively little bias Ghent University dribbling test for both running alone and running with the ball components, and the Bangsbo and Mohr short dribble test. The results of the present study suggest both dribbling tests examined in the present study demonstrate good reliability and low levels of systematic bias.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


2008 ◽  
Vol 22 (6) ◽  
pp. 737-744 ◽  
Author(s):  
I-Ping Hsueh ◽  
Miao-Ju Hsu ◽  
Ching-Fan Sheu ◽  
Su Lee ◽  
Ching-Lin Hsieh ◽  
...  

Objective. To provide empirical justification for selecting motor scales for stroke patients, the authors compared the psychometric properties (validity, responsiveness, test-retest reliability, and smallest real difference [SRD]) of the Fugl-Meyer Motor Scale (FM), the simplified FM (S-FM), the Stroke Rehabilitation Assessment of Movement instrument (STREAM), and the simplified STREAM (S-STREAM). Methods. For the validity and responsiveness study, 50 inpatients were assessed with the FM and the STREAM at admission and discharge to a rehabilitation department. The scores of the S-FM and the S-STREAM were retrieved from their corresponding scales. For the test-retest reliability study, a therapist administered both scales on a different sample of 60 chronic patients on 2 occasions. Results. Only the S-STREAM had no notable floor or ceiling effects at admission and discharge. The 4 motor scales had good concurrent validity (rho ≥ .91) and satisfactory predictive validity (rho = .72-.77). The scales showed responsiveness (effect size d ≥ 0.34; standardized response mean ≥ 0.95; P < .0001), with the S-STREAM most responsive. The test-retest agreements of the scales were excellent (intraclass correlation coefficients ≥ .96). The SRD of the 4 scales was 10% of their corresponding highest score, indicating acceptable level of measurement error. The upper extremity and the lower extremity subscales of the 4 showed similar results. Conclusions. The 4 motor scales showed acceptable levels of reliability, validity, and responsiveness in stroke patients. The S-STREAM is recommended because it is short, responsive to change, and able to discriminate patients with severe or mild stroke.


Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4082 ◽  
Author(s):  
Alexander Peebles ◽  
Lindsay Maguire ◽  
Kristen Renner ◽  
Robin Queen

Clinically feasible methods for quantifying landing kinetics could help identify patients at risk for secondary anterior cruciate ligament injuries. The purpose of this study was to evaluate the validity and between-day repeatability of the loadsol insole during a single-hop and bilateral stop-jump. Thirty healthy recreational athletes completed seven single-hops and seven stop-jumps while simultaneous loadsol (100 Hz) and force plate (1920 Hz) measurements were recorded. Peak impact force, loading rate, and impulse were computed for the dominant limb, and limb symmetry was calculated between limbs for each measure. All outcomes were compared between the loadsol and force plate using intraclass correlation coefficients (ICC) and Bland–Altman plots. Fifteen participants completed a second day of testing to assess between-day repeatability of the loadsol. Finally, an additional 14 participants completed the first day of testing only to assess the validity of the newest generation loadsol, which sampled at 200 Hz. At 100 Hz, validity ICC results were moderate to excellent (0.686–0.982), and repeatability ICC results were moderate to excellent (0.616–0.928). The 200 Hz loadsol demonstrated improved validity ICC (0.765–0.987). Bland–Altman plots revealed that the loadsol underestimated load measures. However, this bias was not observed for symmetry outcomes. The loadsol device is a valid and repeatable tool for evaluating kinetics during landing.


2002 ◽  
Vol 16 (3) ◽  
pp. 283-289 ◽  
Author(s):  
Mark Ferraro ◽  
Jennifer Hogan Demaio ◽  
Jennifer Krol ◽  
Chris Trudell ◽  
Keren Rannekleiv ◽  
...  

The Motor Status Scale (MSS) measures shoulder, elbow (maximum score = 40), wrist, hand, and finger movements (maximum score = 42), and expands the measurement of upper extremity impairment and disability provided by the Fugl-Meyer (FM) score. This work examines the interrater reliability and criterion validity of the MSS performed in patients admitted to a rehabilitation hospital 21 ± 4 days after stroke. Using the MSS and the FM, 7 occupational therapists masked to each other’s judgments, evaluated 12 consecutive patients with stroke. Two therapists evaluated 6 additional patients on consecutive days. Intraclass correlation coefficients were significant for each group of raters for the shoulder/elbow and for the wrist/hand (P < 0.0001); test-retest measures were also significant for the shoulder/elbow (Pearson correlation coefficient r = 0.99, P < 0.004) and for the wrist/hand (Pearson correlation coefficient r = 0.99, P < 0.003). The internal item consistency for the overall MSS was significant (Cronbach alpha = 0.98, P < 0.0001). Finally the correlation between the MSS and the FM (R 2 = 0.964) was significant (P < 0.0001). The MSS affords a reliable and valid assessment of upper limb impairment and disability following stroke.


2018 ◽  
Vol 6 (s2) ◽  
pp. S252-S263 ◽  
Author(s):  
Lisa M. Barnett ◽  
Owen Makin

Assessing young children’s perceptions is commonly done one on one with an interviewer. An app enables several children to complete the scale at once. The objective was to describe an app to assess children’s perceptions of movement competence and then present consistency of child responses. The Pictorial Scale of Perceived Movement Skill Competence (PMSC) has fundamental movement skill (FMS; e.g., catch) and play items (e.g., cycling). The PMSC android app has the same items and images but children complete it independently with audio. Intraclass correlation coefficients (ICC) assessed i) test-retest reliability using the PMSC app on 18 items in 42 children (M = 6.8 yrs) and ii) consistency between measures for 13 FMS items in 44 children (M = 8.5 yrs). Over time (M = 6.9 days, SD = 0.35) the full PMSC had good consistency (ICC = 0.79, 95% CI 0.64–0.88) and the FMS items had moderate consistency (ICC = 0.68, 95% CI 0.47–0.81). There was good agreement between the app and interview for FMS items (ICC = 0.86, 95% CI 0.76–0.92). Locomotor items were less consistent. The PMSC app can generally be recommended. Future research could investigate how different forms of digital assessment affect children’s perception.


2020 ◽  
Vol 47 (4) ◽  
pp. 479-486
Author(s):  
Yuki Kondo ◽  
Kyota Bando ◽  
Yosuke Ariake ◽  
Wakana Katsuta ◽  
Kyoko Todoroki ◽  
...  

BACKGROUND: The reliability of the evaluation of the Balance Evaluation Systems Test (BESTest) and its two abbreviated versions are confirmed for balance characteristics and reliability. However, they are not utilized in cases of spinocerebellar ataxia (SCA). OBJECTIVE: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BESTest and its abbreviated versions in persons with mild to moderate spinocerebellar ataxia. METHODS: The BESTest was performed in 20 persons with SCA at baseline and one month later. The scores of the abbreviated version of the BESTest were determined from the BESTest scores. The interclass correlation coefficient (1,1) was used as a measure of relative reliability. Furthermore, we calculated the MDC in the BESTest and its abbreviated versions. RESULTS: The intraclass correlation coefficients (1,1) and MDC at 95% confidence intervals were 0.92, 8.7(8.1%), 0.91, 4.1(14.5%), and 0.81, 5.2(21.6%) for the Balance, Mini-Balance, and Brief-Balance Evaluation Systems Tests, respectively. CONCLUSIONS: The BESTest and its abbreviated versions had high test-retest reliability. The MDC values of the BESTest could enable clinicians and researchers to interpret changes in the balance of patients with SCA more precisely.


Sign in / Sign up

Export Citation Format

Share Document