scholarly journals Test-Retest Reliability of the King-Devick Test in an Adolescent Population

2017 ◽  
Vol 52 (5) ◽  
pp. 439-445 ◽  
Author(s):  
Tyler J. Oberlander ◽  
Bernadette L. Olson ◽  
Lee Weidauer

Context:  The King-Devick (KD) test is a screening tool designed to assess cognitive visual impairments, namely saccadic rhythm, postconcussion. Test-retest reliability of the KD in a healthy adolescent population has not yet been established. Objective:  To investigate the overall test-retest reliability of the KD among a sample of healthy adolescents. Additionally, we sought to determine if sex and age influenced reliability. Design:  Cross-sectional study. Setting:  Secondary school. Patients or Other Participants:  Sixty-eight healthy adolescents, 41 boys (age = 15.4 ± 1.9 years) and 27 girls (age = 15.4 ± 1.9 years). Main Outcome Measure(s):  Participants completed the KD (version 1) at 3 testing sessions (days 1, 30, and 45) following standard instructions. We recorded total time to complete the reading of 3 cards for each participant during each testing session. Two-way random-effects intraclass correlation coefficients (ICCs) using single measurements repeated over time and repeatability coefficients were calculated. Linear mixed models were used to determine whether differences existed at each testing time and to examine whether changes that took place among visits were different by sex or age. Results:  Adolescents who completed the KD demonstrated acceptable reliability (ICC = 0.81; 95% confidence interval = 0.73, 0.87); however, the repeatability coefficient was large (±8.76 seconds). The sample demonstrated improvements between visits 1 and 2 (mean ± standard error = 4.3 ± 0.5 seconds, P < .001) and between visits 2 and 3 (2.4 ± 0.5 seconds, P < .001) for a total improvement of 6.9 seconds over 3 tests. No significant visit-by-sex or visit-by-age interactions were observed. Conclusions:  Despite the ICC being clinically acceptable, providers using the KD test for serial assessment of concussion in adolescents should be cautious in interpreting the results due to a large learning effect. Incorporating multiple measures can ensure accurate detection of sport concussion.

Author(s):  
Jaroslava Kopcakova ◽  
Zuzana Dankulincova Veselska ◽  
Michal Kalman ◽  
Daniela Filakovska Bobakova ◽  
Dagmar Sigmundova ◽  
...  

The aim of this study was to investigate the test–retest reliability of the motives for undertaking physical activity (PA) items from the Health Behavior in School-Aged Children (HBSC) study questionnaire among Slovak and Czech adolescents and to determine whether this reliability differs by gender, age group and country. We obtained data from 580 students aged 11 and 15 years old (51.2% boys) who participated in a test and retest study with a four-week interval in 2013 via the Health Behavior in School-Aged Children cross-sectional study in the Czech Republic and Slovakia. We estimated the test–retest reliability of all 13 dichotomized motives by using Intraclass Correlation Coefficients (ICC) and Cohen’s Kappa statistics, for continuous and dichotomized motives, respectively. Test–retest reliability showed moderate agreement for nine motives (ICC from 0.41 to 0.60) and fair agreement for four motives (ICC from 0.33 to 0.40). Kappa statistics were similarly moderate to large (0.33 to 0.61), except for three motives with small or trivial correlations. The motives “To improve my health” and “To enjoy the feeling of using my body” had consistently low Kappas and correlations. Overall, the results of this study suggest that most questions on motives for PA on the HBSC questionnaire have acceptable test–retest characteristics for use among adolescents.


2008 ◽  
Vol 22 (6) ◽  
pp. 737-744 ◽  
Author(s):  
I-Ping Hsueh ◽  
Miao-Ju Hsu ◽  
Ching-Fan Sheu ◽  
Su Lee ◽  
Ching-Lin Hsieh ◽  
...  

Objective. To provide empirical justification for selecting motor scales for stroke patients, the authors compared the psychometric properties (validity, responsiveness, test-retest reliability, and smallest real difference [SRD]) of the Fugl-Meyer Motor Scale (FM), the simplified FM (S-FM), the Stroke Rehabilitation Assessment of Movement instrument (STREAM), and the simplified STREAM (S-STREAM). Methods. For the validity and responsiveness study, 50 inpatients were assessed with the FM and the STREAM at admission and discharge to a rehabilitation department. The scores of the S-FM and the S-STREAM were retrieved from their corresponding scales. For the test-retest reliability study, a therapist administered both scales on a different sample of 60 chronic patients on 2 occasions. Results. Only the S-STREAM had no notable floor or ceiling effects at admission and discharge. The 4 motor scales had good concurrent validity (rho ≥ .91) and satisfactory predictive validity (rho = .72-.77). The scales showed responsiveness (effect size d ≥ 0.34; standardized response mean ≥ 0.95; P < .0001), with the S-STREAM most responsive. The test-retest agreements of the scales were excellent (intraclass correlation coefficients ≥ .96). The SRD of the 4 scales was 10% of their corresponding highest score, indicating acceptable level of measurement error. The upper extremity and the lower extremity subscales of the 4 showed similar results. Conclusions. The 4 motor scales showed acceptable levels of reliability, validity, and responsiveness in stroke patients. The S-STREAM is recommended because it is short, responsive to change, and able to discriminate patients with severe or mild stroke.


2021 ◽  
Vol 8 ◽  
Author(s):  
Yunru Liao ◽  
Zhenlan Yang ◽  
Zijing Li ◽  
Rui Zeng ◽  
Jing Wang ◽  
...  

Purpose: Purpose of this study is to evaluate the measuring consistency of central refraction between multispectral refraction topography (MRT) and autorefractometry.Methods: This was a descriptive cross-sectional study including subjects in Sun Yat-sen Memorial Hospital from September 1, 2020, to December 31, 2020, ages 20 to 35 years with a best corrected visual acuity of 20/20 or better. All patients underwent cycloplegia, and the refractive status was estimated with autorefractometer, experienced optometrist and MRT. We analyzed the central refraction of the autorefractometer and MRT. The repeatability and reproducibility of values measured using both devices were evaluated using intraclass correlation coefficients (ICCs).Results: A total of 145 subjects ages 20 to 35 (290 eyes) were enrolled. The mean central refraction of the autorefractometer was −4.69 ± 2.64 diopters (D) (range −9.50 to +4.75 D), while the mean central refraction of MRT was −4.49 ± 2.61 diopters (D) (range −8.79 to +5.02 D). Pearson correlation analysis revealed a high correlation between the two devices. The intraclass correlation coefficient (ICC) also showed high agreement. The intrarater and interrater ICC values of central refraction were more than 0.90 in both devices and conditions. At the same time, the mean central refraction of experienced optometrist was −4.74 ± 2.66 diopters (D) (range −9.50 to +4.75D). The intra-class correlation coefficient of central refraction measured by MRT and subjective refraction was 0.939.Conclusions: Results revealed that autorefractometry, experienced optometrist and MRT show high agreement in measuring central refraction. MRT could provide a potential objective method to assess peripheral refraction.


2020 ◽  
Vol 47 (4) ◽  
pp. 479-486
Author(s):  
Yuki Kondo ◽  
Kyota Bando ◽  
Yosuke Ariake ◽  
Wakana Katsuta ◽  
Kyoko Todoroki ◽  
...  

BACKGROUND: The reliability of the evaluation of the Balance Evaluation Systems Test (BESTest) and its two abbreviated versions are confirmed for balance characteristics and reliability. However, they are not utilized in cases of spinocerebellar ataxia (SCA). OBJECTIVE: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BESTest and its abbreviated versions in persons with mild to moderate spinocerebellar ataxia. METHODS: The BESTest was performed in 20 persons with SCA at baseline and one month later. The scores of the abbreviated version of the BESTest were determined from the BESTest scores. The interclass correlation coefficient (1,1) was used as a measure of relative reliability. Furthermore, we calculated the MDC in the BESTest and its abbreviated versions. RESULTS: The intraclass correlation coefficients (1,1) and MDC at 95% confidence intervals were 0.92, 8.7(8.1%), 0.91, 4.1(14.5%), and 0.81, 5.2(21.6%) for the Balance, Mini-Balance, and Brief-Balance Evaluation Systems Tests, respectively. CONCLUSIONS: The BESTest and its abbreviated versions had high test-retest reliability. The MDC values of the BESTest could enable clinicians and researchers to interpret changes in the balance of patients with SCA more precisely.


2012 ◽  
Vol 92 (9) ◽  
pp. 1197-1207 ◽  
Author(s):  
Parminder K. Padgett ◽  
Jesse V. Jacobs ◽  
Susan L. Kasser

Background The Balance Evaluation Systems Test (BESTest) and Mini-BESTest are clinical examinations of balance impairment, but the tests are lengthy and the Mini-BESTest is theoretically inconsistent with the BESTest. Objective The purpose of this study was to generate an alternative version of the BESTest that is valid, reliable, time efficient, and founded upon the same theoretical underpinnings as the original test. Design This was a cross-sectional study. Methods Three raters evaluated 20 people with and without a neurological diagnosis. Test items with the highest item-section correlations defined the new Brief-BESTest. The validity of the BESTest, the Mini-BESTest, and the new Brief-BESTest to identify people with or without a neurological diagnosis was compared. Interrater reliability of the test versions was evaluated by intraclass correlation coefficients. Validity was further investigated by determining the ability of each version of the examination to identify the fall status of a second cohort of 26 people with and without multiple sclerosis. Results Items of hip abductor strength, functional reach, one-leg stance, lateral push-and-release, standing on foam with eyes closed, and the Timed “Up & Go” Test defined the Brief-BESTest. Intraclass correlation coefficients for all examination versions were greater than .98. The accuracy of identifying people from the first cohort with or without a neurological diagnosis was 78% for the BESTest versus 72% for the Mini-BESTest or Brief-BESTest. The sensitivity to fallers from the second cohort was 100% for the Brief-BESTest, 71% for the Mini-BESTest, and 86% for the BESTest, and all versions exhibited specificity of 95% to 100% to identify nonfallers. Limitations Further testing is needed to improve the generalizability of findings. Conclusions Although preliminary, the Brief-BESTest demonstrated reliability comparable to that of the Mini-BESTest and potentially superior sensitivity while requiring half the items of the Mini-BESTest and representing all theoretically based sections of the original BESTest.


2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Taher I. Omari ◽  
Johanna Savilampi ◽  
Karmen Kokkinn ◽  
Mistyka Schar ◽  
Kristin Lamvik ◽  
...  

Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements.Methods. Five subjects swallowed10×10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing.Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showedsubstantialtoexcellentagreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged fromslighttoexcellentdepending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showedexcellenttest-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showedmoderatetosubstantialtest-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged fromslighttosubstantial(mean Interrater ICC 0.15–0.61).Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility.


2021 ◽  
pp. 1-4
Author(s):  
Jamon Couch ◽  
Marc Sayers ◽  
Tania Pizzari

Context: An imbalance between shoulder internal rotation (IR) and external rotation (ER) strength in athletes is proposed to increase the risk of sustaining a shoulder injury. Hand-held (HHD) and externally fixed dynamometry are reliable forms of assessing shoulder IR and ER strength. A new externally fixed device with an attachable fixed upper-limb mold (The ForceFrame) exists; however, its reliability in measuring shoulder strength is yet to be investigated. Objective: To determine the test–retest reliability of the ForceFrame, with and without the fixed upper-limb mold, in the assessment of shoulder IR and ER strength, as compared with HHD. Design: Test–retest reliability study. Setting: Laboratory, clinical. Participants: Twenty-two healthy and active individuals were recruited from the university community and a private physiotherapy practice. Main Outcome Measures: Maximal isometric shoulder IR and ER strength was measured using the ForceFrame and traditional HHD in neutral and at 90° shoulder abduction. Mean (SD) strength measures were calculated. Test–retest reliability was analyzed using intraclass correlation coefficients (3, 1). The SEM and minimal detectable change were calculated. Results: Good to excellent test–retest reliability was found for all shoulder strength tests across Hand-held dynamometry (HHD) and externally fixed dynamometry (EFD) are reliable forms (intraclass correlation coefficients [3, 1] = .854–.916). The minimal detectable changes ranged between 25.61 and 41.84 N across tests. Test–retest reliability was not affected by the dynamometer or testing position. Conclusions: The results from this study indicate that both the ForceFrame and HHD are suitable for measuring shoulder strength in clinical practice. The use of the fixed upper-limb mold with the ForceFrame does not improve reliability.


2021 ◽  
pp. 1-6
Author(s):  
Fei Tian ◽  
Yaqi Zhao ◽  
Jixin Li ◽  
Wenjin Wang ◽  
Danni Wu ◽  
...  

Context: Many methods used to evaluate knee proprioception have shortcomings that limit their use in clinical settings. Based on an inexpensive 3D camera, a new portable device was recently used to evaluate the joint position sense (JPS) of the knee joint. However, the test–retest reliability of the new method remains unclear. This study aimed to evaluate the test–retest reliability of the new device and a long-arm goniometer for assessing knee JPS, and to compare the variability of the 2 methods. Design: Prospective observational study of the test–retest reliability of knee JPS measurements. Methods: Twenty-one healthy adults were tested in 2 sessions with a 1-week interval. Three target knee flexion angles (30°, 45°, and 60°) were reproduced in each session. Target and reproduced angles were measured with both methods. Intraclass correlation coefficients, standard error of the measurement, and Bland–Altman plots were used to quantify test–retest reliability. Paired t tests were used to compare knee JPS (absolute error of the target-reproduced angle) between the methods. Results: The new device (good to excellent intraclass correlation coefficients .74–.80; standard error of the measurement 0.52°–0.61°) demonstrated better test–retest reliability than the goniometer (poor to fair intraclass correlation coefficients .23–.43; standard error of the measurement 0.89°–2.07°) and better test–retest agreement (respective mean differences for the 30°, 45°, and 60° knee angles: 0.11°, 0.13°, and 0.41° for the new system; 0.84°, 1.52°, and 1.18° for the goniometer). The measurements (absolute errors of the target-reproduced angles) with the goniometer were significantly greater than those with the new device (P < .05); the SDs of repeated measurements with the goniometer (1.50°–2.41°) were greater than with the new device (1.08°–1.38°). Conclusions: Given that the new device has good reliability and sufficient precision, it is the better alternative for evaluating knee JPS. Goniometers should be used with caution to assess knee JPS.


2014 ◽  
Vol 114 (1) ◽  
pp. 93-103 ◽  
Author(s):  
Tomas Larson ◽  
Eva Norén Selinus ◽  
Clara Hellner Gumpert ◽  
Thomas Nilsson ◽  
Nóra Kerekes ◽  
...  

The Autism-Tics, AD/HD, and other Comorbidities (A–TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A–TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A–TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's κ. A–TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A–TAC had intra- and inter-rater reliability intraclass correlation coefficients of ≥ .60. Cohen's κ indicated acceptable reliability. The current study provides statistical evidence that the A–TAC yields good test-retest reliability in a population-based cohort of children.


Sign in / Sign up

Export Citation Format

Share Document