Routine Analysis of the Alpha Activity of Protactinium Samples

Science ◽  
1947 ◽  
Vol 106 (2756) ◽  
pp. 400-401 ◽  
Author(s):  
M. BLAU ◽  
H. SINASON
Author(s):  
John A. Hunt ◽  
Richard D. Leapman ◽  
David B. Williams

Interactive MASI involves controlling the raster of a STEM or SEM probe to areas predefined byan integration mask which is formed by image processing, drawing or selecting regions manually. EELS, x-ray, or other spectra are then acquired while the probe is scanning over the areas defined by the integration mask. The technique has several advantages: (1) Low-dose spectra can be acquired by averaging the dose over a great many similar features. (2) MASI can eliminate the risks of spatial under- or over-sampling of multiple, complicated, and irregularly shaped objects. (3) MASI is an extremely rapid and convenient way to record spectra for routine analysis. The technique is performed as follows:Acquire reference imageOptionally blank beam for beam-sensitive specimensUse image processor to select integration mask from reference imageCalculate scanning path for probeUnblank probe (if blanked)Correct for specimen drift since reference image acquisition


2000 ◽  
Vol 14 (3) ◽  
pp. 151-158 ◽  
Author(s):  
José Luis Cantero ◽  
Mercedes Atienza

Abstract High-resolution frequency methods were used to describe the spectral and topographic microstructure of human spontaneous alpha activity in the drowsiness (DR) period at sleep onset and during REM sleep. Electroencephalographic (EEG), electrooculographic (EOG), and electromyographic (EMG) measurements were obtained during sleep in 10 healthy volunteer subjects. Spectral microstructure of alpha activity during DR showed a significant maximum power with respect to REM-alpha bursts for the components in the 9.7-10.9 Hz range, whereas REM-alpha bursts reached their maximum statistical differentiation from the sleep onset alpha activity at the components between 7.8 and 8.6 Hz. Furthermore, the maximum energy over occipital regions appeared in a different spectral component in each brain activation state, namely, 10.1 Hz in drowsiness and 8.6 Hz in REM sleep. These results provide quantitative information for differentiating the drowsiness alpha activity and REM-alpha by studying their microstructural properties. On the other hand, these data suggest that the spectral microstructure of alpha activity during sleep onset and REM sleep could be a useful index to implement in automatic classification algorithms in order to improve the differentiation between the two brain states.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jelena Trajkovic ◽  
Francesco Di Gregorio ◽  
Francesca Ferri ◽  
Chiara Marzi ◽  
Stefano Diciotti ◽  
...  

AbstractSchizophrenia is among the most debilitating neuropsychiatric disorders. However, clear neurophysiological markers that would identify at-risk individuals represent still an unknown. The aim of this study was to investigate possible alterations in the resting alpha oscillatory activity in normal population high on schizotypy trait, a physiological condition known to be severely altered in patients with schizophrenia. Direct comparison of resting-state EEG oscillatory activity between Low and High Schizotypy Group (LSG and HSG) has revealed a clear right hemisphere alteration in alpha activity of the HSG. Specifically, HSG shows a significant slowing down of right hemisphere posterior alpha frequency and an altered distribution of its amplitude, with a tendency towards a reduction in the right hemisphere in comparison to LSG. Furthermore, altered and reduced connectivity in the right fronto-parietal network within the alpha range was found in the HSG. Crucially, a trained pattern classifier based on these indices of alpha activity was able to successfully differentiate HSG from LSG on tested participants further confirming the specific importance of right hemispheric alpha activity and intrahemispheric functional connectivity. By combining alpha activity and connectivity measures with a machine learning predictive model optimized in a nested stratified cross-validation loop, current research offers a promising clinical tool able to identify individuals at-risk of developing psychosis (i.e., high schizotypy individuals).


1990 ◽  
Vol 265 (27) ◽  
pp. 16158-16165 ◽  
Author(s):  
R D Kuchta ◽  
B Reid ◽  
L M Chang
Keyword(s):  

1994 ◽  
Vol 10 (4-5) ◽  
pp. 633-643
Author(s):  
Gary E. Schwartz ◽  
Iris R. Bell ◽  
Ziya V. Dikman ◽  
Mercedes Fernandez ◽  
John P. Kline ◽  
...  

Recent studies from the University of Arizona indicate that normal subjects, both college students and the elderly, can register the presence of low-intensity odors in the electroencephalogram (EEG) in the absence of conscious awareness of the odors. The experimental paradigm involves subjects sniffing pairs of bottles, one containing an odorant (e.g. isoamyl acetate) dissolved in an odorless solvent (water or liquid silicone), the other containing just the solvent, while 19 channels of EEG are continuously recorded. For the low-intensity odor conditions, concentrations are adjusted downward (decreased) until subjects correctly identify the odor bottle at chance (50). The order of odorants, concentrations, and hand holding the control bottle, are counterbalanced within and across subjects. Three previous experiments found that alpha activity (8-12 hz) decreased in midline and posterior regions when subjects sniffed the low-intensity odors. The most recent study suggests that decreased theta activity (4-8 hz) may reflect sensory registration and decreased alpha activity may reflect perceptual registration. In a just completed experiment involving college students who were selected based on combinations of high and low scores on a scale measuring cacosmia (chemical odor intolerance) and high and low scores on a scale measuring depression, cacosmic subjects (independent of depression) showed greater decreases in low-frequency alpha (8-10 hz) and greater increases in low-frequency beta (12-16 hz) to the solvent propylene glycol compared to an empty bottle. Topographic EEG mapping to low-intensity odorants may provide a useful tool for investigating possible increased sensitivity to specific chemicals in chemically sensitive individuals.


2021 ◽  
pp. 193229682110116
Author(s):  
Jan S. Krouwer

Unlike performance evaluations, which are often conducted under ideal conditions, adverse events occur during actual device use for people with diabetes. This report summarizes the number of adverse events for the years 2018 to 2020 for the 3 diabetes devices: blood glucose meters (BG), continuous glucose monitors (CGM), and insulin pumps. A text example of a CGM injury is provided. Possible reasons are suggested for trends. Whereas the rate per test result (events/usage) is exceedingly small, the rate per patient (events/people with diabetes that use insulin) is of concern. Hence, it is important to determine event causes and provide corrective actions. The first step is to put in place routine analysis of adverse event data for diabetes devices.


2016 ◽  
Vol 150 (4) ◽  
pp. S997-S998
Author(s):  
Pablo M. Linares ◽  
H de la Fuente ◽  
María Chaparro ◽  
Iván Guerra ◽  
Pedro L. Majano ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document