scholarly journals Comparison of membrane filtration and Autoanalysis Colilert presence-absence techniques for analysis of total coliforms and Escherichia coli in drinking water samples.

1989 ◽  
Vol 55 (12) ◽  
pp. 3091-3094 ◽  
Author(s):  
C M Lewis ◽  
J L Mak
1998 ◽  
Vol 64 (8) ◽  
pp. 3079-3083 ◽  
Author(s):  
Karl F. Eckner

ABSTRACT A total of 338 water samples, 261 drinking water samples and 77 bathing water samples, obtained for routine testing were analyzed in duplicate by Swedish standard methods using multiple-tube fermentation or membrane filtration and by the Colilert and/or Enterolert methods. Water samples came from a wide variety of sources in southern Sweden (Skåne). The Colilert method was found to be more sensitive than Swedish standard methods for detecting coliform bacteria and of equal sensitivity for detecting Escherichia coli when all drinking water samples were grouped together. Based on these results, Swedac, the Swedish laboratory accreditation body, approved for the first time in Sweden use of the Colilert method at this laboratory for the analysis of all water sources not falling under public water regulations (A-krav). The coliform detection study of bathing water yielded anomalous results due to confirmation difficulties. E. coli detection in bathing water was similar by both the Colilert and Swedish standard methods as was fecal streptococcus and enterococcus detection by both the Enterolert and Swedish standard methods.


2008 ◽  
Vol 54 (6) ◽  
pp. 495-500 ◽  
Author(s):  
B. Lévesque ◽  
D. Pereg ◽  
E. Watkinson ◽  
J.S. Maguire ◽  
L. Bissonnette ◽  
...  

Bermuda residents collect rainwater from rooftops to fulfil their freshwater needs. The objective of this study was to assess the microbiological quality of drinking water in household tanks throughout Bermuda. The tanks surveyed were selected randomly from the electoral register. Governmental officers visited the selected household (n = 102) to collect water samples and administer a short questionnaire about the tank characteristics, the residents’ habits in terms of water use, and general information on the water collecting system and its maintenance. At the same time, water samples were collected for analysis and total coliforms and Escherichia coli were determined by 2 methods (membrane filtration and culture on chromogenic media, Colilert kit). Results from the 2 methods were highly correlated and showed that approximately 90% of the samples analysed were contaminated with total coliforms in concentrations exceeding 10 CFU/100 mL, and approximately 66% of samples showed contamination with E. coli. Tank cleaning in the year prior to sampling seems to protect against water contamination. If rainwater collection from roofs is the most efficient mean for providing freshwater to Bermudians, it must not be considered a source of high quality drinking water because of the high levels of microbial contamination.


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2005 ◽  
Vol 3 (3) ◽  
pp. 221-228 ◽  
Author(s):  
J. T. Macy ◽  
E. F. Dunne ◽  
S. P. Luby ◽  
Y. H. Angoran-Benie ◽  
Y. Kamelan-Tano ◽  
...  

Membrane filtration, multiple tube fermentation (the standard methods) and Colilert are techniques available for assessing drinking water quality, but there are no published comparisons of Colilert to standard methods in a developing country laboratory. We reviewed the published literature on Colilert and standard methods and conducted a study to compare Colilert with membrane filtration for the detection and enumeration of total coliforms and fecal coliforms (Escherichia coli bacteria) using 35 stored drinking water samples from households in Abidjan, Côte d'Ivoire. Our study results are consistent with previous published studies conducted in developed countries. Results from Colilert and membrane filtration correlated for both total coliforms (r2=0.81) and E. coli (r2=0.93). Colilert is an acceptable method to measure the presence and quantity of coliforms in water samples in a developing country setting.


2021 ◽  
Vol 10 (1) ◽  
pp. 23
Author(s):  
Muhammad Rayhan Braja Gitawama ◽  
Netti Suharti ◽  
Nora Harminarti

The National Food and Drug Agency has controlled the refill drinking water in drinking water depots and also controlled food at school canteens ranging from elementary, junior high, to high school, but the National Food and Drug Agency never do food quality controlling in canteens at universities. Objectives: To identified the contamination by coliform and E. coli bacteria in drinking water at Andalas University canteen. Methods: This research was descriptive to identify coliform bacteria on  15 drinking water at the Andalas University faculty canteens.  Samples were taken directly using a sterile bottle, while data analysis using Most Probable Number  (MPN)  tables 5-1-1 and the presence of E. coli bacteria colonies from drinking water samples. Results: 9 of 15 water samples were contaminated by coliform bacteria with the highest MPN index of 240/100 ml that was found in 2 samples. From 9 samples containing coliform bacteria, all of them were found to contain E. coli bacteria. Conclusion: Most of the samples were contaminated by coliform and E. coli bacteria. Drinking water served using a kettle was more contaminated than drinking water served using gallons.Keywords: Coliform, Escherichia coli, MPN


2002 ◽  
Vol 2 (3) ◽  
pp. 9-15 ◽  
Author(s):  
R.A.B. Nichols ◽  
C.A. Paton ◽  
B.M. Campbell ◽  
J. Wastling ◽  
H.V. Smith

We describe a semi-quantitative PCR-RFLP method for detecting low densities of Cryptosporidium spp. oocysts present in final drinking water samples and natural mineral waters. UK Standard Operating Protocols were used to concentrate oocysts from drinking water samples. Oocysts were concentrated from mineral waters by membrane filtration. Cryptosporidium oocysts identified by epifluorescence microscopy on slides or filters were subjected to DNA extraction and PCR-RFLP analysis. Oocysts were disrupted by freeze-thawing in lysis buffer. Amplicons were readily detected from 2 to 5 intact oocysts on ethidium bromide stained gels following 1 round of PCR. DNA extracted from C. parvum, C. muris, C. baileyi, human-derived C. meleagridis, and C. felis were used to confirm species identity by PCR-RFLP following simultaneous digestion with DraI and VspI.