scholarly journals Immunosorbent Assay Based on Recombinant Hemagglutinin Protein Produced in a High-Efficiency Mammalian Expression System for Surveillance of Measles Immunity

1998 ◽  
Vol 36 (3) ◽  
pp. 721-726 ◽  
Author(s):  
Fabienne Bouche ◽  
Wim Ammerlaan ◽  
Francoise Berthet ◽  
Sophie Houard ◽  
Francois Schneider ◽  
...  

Recombinant hemagglutinin (H) protein of the measles virus (MV) was produced in mammalian cells with a high-yield expression system based on the Semliki Forest virus replicon. Crude membrane preparations of H protein-transfected BHK-21 cells were used to coat microtiter plates to measure specific immunoglobulin G antibodies in 228 serologically defined serum samples mainly from measles late-convalescent adults. The titers by the enzyme-linked immunosorbent assay for the H protein (H-ELISA) closely correlated with neutralization test (NT) titers (R 2 = 0.66), hemagglutination inhibition test (HI) titers (R 2 = 0.64), with the titers from a certified commercial ELISA based on whole MV-infected cells (MV-ELISA;R 2 = 0.45). The correlations described above were better than those of the commercial MV-ELISA titers with the NT (R 2 = 0.52) or HI (R 2 = 0.48) titers. By using the 2nd International Standard for anti-measles serum, the detection level of the assay corresponds to 215 mIU/ml for undiluted serum, which corresponds to the estimated threshold for protective immunity. The specificity, accuracy, and positive predictive value were, in general, better for the H-ELISA than for a commercial MV-ELISA, independent of whether HI, NT, or HI and NT were used as “gold standards.” In contrast, the H-ELISA proved to be slightly less sensitive than the MV-ELISA (sensitivities, 98.6 versus 99.5%, respectively;P was not significant). The assays did not differ significantly in the number of serum samples with positive HI and NT results (n = 212) which measured false negative (H-ELISA, 2 of 212 [0.94%]; MV-ELISA, 1 of 212 [0.47%]), but the H-ELISA detected significantly more measles-susceptible individuals than the MV-ELISA (10 of 11 versus 3 of 11, respectively;P < 0.05) among the individuals whose sera had negative HI and NT results. Our data demonstrate that the H-protein preparation that we describe could be a cost-effective alternative to current whole-virus-based ELISAs for surveillance for immunity to measles and that such an assay could be more efficient in detecting susceptibility to measles. Furthermore, unlike whole MV-based antigens, H-protein would also be suitable for use in the development of a simple field test for the diagnosis of measles.

1998 ◽  
Vol 36 (12) ◽  
pp. 3509-3513 ◽  
Author(s):  
Fabienne B. Bouche ◽  
Nicolaas H. C. Brons ◽  
Sophie Houard ◽  
Francois Schneider ◽  
Claude P. Muller

Recombinant hemagglutinin (H) of the measles virus (MV) expressed in a mammalian high-expression system based on the Semliki Forest virus replicon was used in an enzyme-linked immunosorbent assay (ELISA) for the detection of specific immunoglobulin M (IgM) and IgG in patients with acute-phase measles. One hundred twelve serum specimens from 70 patients with measles were analyzed. Case definition was based on a commercial IgM ELISA that utilizes MV-infected cells (MV-ELISA) (Enzygnost; Behring Diagnostics); the clinical criteria of the Centers for Disease Control and Prevention (Atlanta, Ga.); and/or the increase in hemagglutinin test titers, neutralization test titers, and levels of MV-specific IgG whenever paired sera were available. The initial time courses of the IgM signal after the onset of rash are similar in the H- and MV-ELISAs. On days 0 to 19, both ELISAs detected IgM in 67 of 68 (98.5%) sera. Average maximal levels of IgM seem to persist, however, about 10 days longer in the MV-ELISA (up to day 25) than in the H-ELISA (day 15). From days 20 to 29 and 30 to 59, the H-ELISA detected only 64.3 (9 of 14) and 19.2% (5 of 26), respectively, of sera that were IgM positive by MV-ELISA. At least up to day 30, the performance of the H-ELISA seemed to be similar to that reported for commercial ELISAs based on whole MV. Our results demonstrate that MV H-specific IgM can be used to diagnose most measles cases from a single serum specimen collected within 19 days after the onset of rash and that the recombinant protein used in this study is suitable for this purpose.


2003 ◽  
Vol 10 (3) ◽  
pp. 439-442 ◽  
Author(s):  
F. Roodbari ◽  
M. H. Roustai ◽  
A. Mostafaie ◽  
H. Soleimanjdahi ◽  
R. Sarrami Foroshani ◽  
...  

ABSTRACT Measles is a highly contagious respiratory virus infection, with typical clinical symptoms including maculopapular rash, fever, cough, coryza, and conjunctivitis. Despite implementation of widespread vaccination programs throughout the world, the rates of global morbidity and mortality are still considerable. This study was performed to design a reliable indirect enzyme-linked immunosorbent assay (ELISA) to measure measles-specific immunoglobulin M (IgM). First, human IgM was purified, and then an anti-IgM antibody was produced in rabbits and purified in a multistep process. The rabbit IgG against human IgM was conjugated with peroxidase. Measles virus-infected Vero cells produced viral antigen. One hundred serum samples from infants of 9 to 18 months of age, mostly vaccinated, were evaluated for determining the presence of specific IgM antibodies against measles virus. The samples were also evaluated for neutralizing antibodies against measles virus by a microneutralization test (MNT). By comparing the results of the ELISA with those of MNT, it was demonstrated that ELISA had a sensitivity and specificity of 100 and 92%, respectively. On the other hand, when the results obtained by our ELISA system were compared with those of an imported measles virus IgM ELISA kit (EIAgen; Adaltis Italia SPa, Bologna, Italy), a high level of agreement was shown (k = 0.926).


2010 ◽  
Vol 17 (9) ◽  
pp. 1481-1483 ◽  
Author(s):  
V. A. Arankalle ◽  
R. G. Virkar ◽  
B. V. Tandale ◽  
N. B. Ingle

ABSTRACT An enzyme-linked immunosorbent assay (ELISA) for the detection of IgG antibodies against the pandemic H1N1 2009 influenza A virus, employing a recombinant hemagglutinin protein of the virus, was compared to the hemagglutination inhibition (HI) test using 783 serum samples. The results showed a concordance of 98.4%, suggesting the utility of the ELISA in serosurveillance. Two hundred sixty-nine (100%) serum samples with an HI titer of ≥20 were ELISA reactive.


2016 ◽  
Vol 42 (03) ◽  
pp. 165-170
Author(s):  
Hui-Wen Chen ◽  
Ting-Hsiang Hsiao ◽  
Ching-Ho Wang

Reticuloendotheliosis virus (REV) infects various animals including chickens, ducks, geese, pheasants, peafowl and other birds. REV causes tumor, runting disease syndrome and immunosuppression in infected birds. The purpose of this study was to develop a rapid, reliable and convenient method to detect anti-REV antibody. The REV envelope protein was expressed by baculovirus expression system and evaluated for the potential as an antigen in an enzyme linked-immunosorbent assay (ELISA). The env gene from a REV strain goose/3410/06 was cloned into bacmid vector and expressed in Sf9 insect cells. The expected recombinant envelope protein expressed in infected insect cells was demonstrated in western blot with size of 62 kDa, and purified for using as antigen in an ELISA. A total of 182 chicken serum samples were used to evaluate the suitability of the ELISA based on neutralization test as the gold standard. The results showed that the relative sensitivity and relative specificity of this ELISA were 88.5% and 97.7%, respectively. The present ELISA using baculovirus expression envelope protein can be used to detect anti-REV antibody in the field.


2007 ◽  
Vol 53 (6) ◽  
pp. 720-726 ◽  
Author(s):  
S. Khamehchian ◽  
R. Madani ◽  
M.J. Rasaee ◽  
F. Golchinfar ◽  
R. Kargar

A competitive enzyme-linked immunosorbent assay (C-ELISA) has been developed and standardized for the detection of antibodies to the rinderpest virus (RPV) in sera from cattle, sheep, and goats. The test is specific for rinderpest because it does not detect antibodies to peste-des-petits-ruminants virus (PPRV). The test depends on the ability of the monoclonal antibody (MAb) directed against the hemagglutinin (H) protein of RPV to compete with the binding of RPV antibodies in the positive serum to the H protein of this virus. This MAb recognized a region from amino acids 575 to 583 on the H protein of RPV that is unique to the RPV H protein and is not present on the hemagglutinin-neuraminidase protein of PPRV. Another C-ELISA (peptide C-ELISA) was set up using this specific region as an antigen. A threshold value of 64.4% inhibition was established for the RPV C-ELISA, with 90 known RPV-negative and 30 RPV-positive serum samples. Using common serum samples, a cutoff value of 43.0% inhibition for the peptide C-ELISA was established. Based on statistical analysis, the overall sensitivity and specificity of the RPV C-ELISA, relative to those of a commercial kit, were found to be 90.00% and 103.33%, respectively. However, the sensitivity and specificity of the peptide C-ELISA were found to be 180.00% and 73.33%, respectively. Although a common MAb in 2 new C-ELISA systems was used, variation in their percent inhibition, due to the use of different antigens, was observed. Taking into consideration the difference in percent inhibition of the 2 described assays and the commercial kit (50%), it was found that the RPV C-ELISA and the peptide C-ELISA are more specific and sensitive tools than the commercial kit for assessing herd immune status and for epidemiologic surveillance.


2003 ◽  
Vol 10 (2) ◽  
pp. 267-271 ◽  
Author(s):  
Lynn M. Herrmann ◽  
William P. Cheevers ◽  
Travis C. McGuire ◽  
D. Scott Adams ◽  
Melinda M. Hutton ◽  
...  

ABSTRACT A competitive-inhibition enzyme-linked immunosorbent assay (cELISA) was evaluated for the detection of serum antibodies to the surface envelope (SU) of caprine arthritis-encephalitis virus (CAEV) in goats. This assay utilized 96-well microtiter plates containing CAEV-63 SU captured by monoclonal antibody (MAb) F7-299 and measured the competitive displacement of horseradish peroxidase-conjugated MAb GPB 74A binding by undiluted goat sera (F. Özyörük, W. P. Cheevers, G. A. Hullinger, T. C. McGuire, M. Hutton, and D. P. Knowles, Clin. Diagn. Lab. Immunol. 8:44-51, 2001). Two hundred serum samples from goats in the United States were used to determine the sensitivity and specificity of cELISA based on the immunoprecipitation (IP) of [35S]methionine-labeled viral antigens as a standard of comparison. A positive cELISA was defined as >33.2% inhibition of MAb 74A binding based on 2 standard deviations above the mean percent inhibition of 140 IP-negative serum samples. At this cutoff value, there were 0 of 60 false-negative sera (100% sensitivity) and 5 of 140 false-positive sera (96.4% specificity). Additional studies utilized IP-monitored cELISA to establish a CAEV-free herd of 1,640 dairy goats.


2009 ◽  
Vol 11 (10) ◽  
pp. 881-884 ◽  
Author(s):  
Annamaria Pratelli ◽  
Kadir Yesilbag ◽  
Marcello Siniscalchi ◽  
Ebru Yalçm ◽  
Zeki Yilmaz

Feline sera from Bursa province (Turkey) were assayed for coronavirus antibody using an enzyme-linked immunosorbent assay (ELISA). The study was performed on 100 sera collected from cats belonging to catteries or community shelters and to households. The serum samples were initially tested with the virus neutralisation (VN) test and the results were then compared with the ELISA. The VN yielded 79 negative and 21 positive sera but the ELISA confirmed only 74 as negative. The ELISA-negative sera were also found to be free of feline coronoviruses-specific antibodies by Western blotting. Using the VN as the gold standard test, ELISA had a sensitivity of 100% and a specificity of 93.6%, with an overall agreement of 95%. The Kappa (κ) test indicated high association between the two tests (κ=0.86, 95% confidence interval (CI) 0.743–0.980). The positive predictive value (PPV) was 0.8, and the negative predictive value (NPV) was 0.93. The prevalence of FCoV II antibodies in the sampled population based on the gold standard was 62% (95% CI 0.44–0.77) among multi-cat environments, and 4% (95% CI 0.01–0.11) among single cat households.


2000 ◽  
Vol 12 (2) ◽  
pp. 142-145 ◽  
Author(s):  
James O. Mecham ◽  
Michael M. Jochim

An enzyme-linked immunosorbent assay has been developed to detect antibodies to epizootic hemorrhagic disease of deer virus (EHDV). The assay incorporates a monoclonal antibody to EHDV serotype 2 (EHDV-2) that demonstrates specificity for the viral structural protein, VP7. The assay was evaluated with sequential sera collected from cattle experimentally infected with EHDV serotype 1 (EHDV-1) and EHDV-2, as well as the four serotypes of bluetongue virus (BTV), BTV-10, BTV-11, BTV-13, and BTV-17, that currently circulate in the US. A competitive and a blocking format as well as the use of antigen produced from both EHDV-1-and EHDV-2-infected cells were evaluated. The assay was able to detect specific antibody as early as 7 days after infection and could differentiate animals experimentally infected with EHDV from those experimentally infected with BTV. The diagnostic potential of this assay was demonstrated with field-collected serum samples from cattle, deer, and buffalo.


2021 ◽  
Vol 12 ◽  
Author(s):  
Bochao Liu ◽  
Ze Wu ◽  
Chaolan Liang ◽  
Jinhui Lu ◽  
Jinfeng Li ◽  
...  

Since December 2019, a novel coronavirus (SARS-CoV-2) has resulted in a global pandemic of coronavirus disease (COVID-19). Although viral nucleic acid test (NAT) has been applied predominantly to detect SARS-CoV-2 RNA for confirmation diagnosis of COVID-19, an urgent need for alternative, rapid, and sensitive immunoassays is required for primary screening of virus. In this study, we developed a smartphone-based nanozyme-linked immunosorbent assay (SP-NLISA) for detecting the specific nucleocapsid phosphoprotein (NP) of SARS-CoV-2 in 37 serum samples from 20 COVID-19 patients who were diagnosed by NAT previously. By using SP-NLISA, 28/37 (75.7%) serum samples were detected for NP antigens and no cross-reactivity with blood donors’ control samples collected from different areas of China. In a control assay using the conventional enzyme-linked immunosorbent assay (ELISA), only 7/37 (18.91%) serum samples were detected for NP antigens and no cross-reactivity with control samples. SP-NLISA could be used for rapid detection of SARS-CoV-2 NP antigen in primary screening of SARS-CoV-2 infected individuals.


2010 ◽  
Vol 17 (8) ◽  
pp. 1261-1268 ◽  
Author(s):  
Sridevi V. Nimmagadda ◽  
Shukra M. Aavula ◽  
Neelakantam Biradhar ◽  
Varaprasada Sankarasetty Rao ◽  
Rajalakshmi Shanmugham ◽  
...  

ABSTRACT The potency of rabies vaccines, determined using the NIH mouse protection test, can be directly correlated to the amount of rabies virus glycoprotein (RV GP) present in the vaccine. In an effort to develop a simple and sensitive enzyme-linked immunosorbent assay (ELISA) using recombinant diabody for quantification of RV GP, the variable heavy (VH) and light chain (VL) domains of an RV GP-specific human monoclonal antibody (MAb) secreted by a human × mouse heterohybridoma (human MAb R16E5) was amplified, linked using splicing by overlap extension PCR (SOE PCR), and expressed as a recombinant diabody (D06) in the pET28a bacterial expression system. The diabody D06 was purified by immobilized metal affinity chromatography on a nickel-nitrilotriacetic acid (NTA) agarose column and characterized. The purified diabody was used in combination with a well-characterized RV GP-specific mouse MAb, M5B4, to develop an immunocapture ELISA (IC-ELISA) for the quantification of RV GP in human rabies vaccine preparations. The maximum detection limit of the IC-ELISA using the M5B4-D06 combination was up to 31.25 ng/ml of RV GP. The specificity of the diabody was established by its nonreactivity toward other human viral antigens as determined by ELISA and toward RV GP as determined by immunoblot transfer assay and competitive ELISA with the parent human MAb R16E5 and MAb M5B4. The adjusted r 2 value obtained by the regression through the origin model was 0.902, and the equation for predicted potency values for M5B4-D06-based IC-ELISA and MAb M5B4 IC-ELISA were 0.5651x and 0.8044x, respectively, where x is the estimate of RV GP from the IC-ELISA in micrograms. Analysis of variance (ANOVA) results showed the estimates of the two methods differed significantly (P < 0.001), while the predicted potencies by the two tests did not differ significantly (P > 0.05). The IC-ELISA can be readily adapted to measure the RV GP content in purified antigen, and a vaccine can be formulated based on the estimated GP.


Sign in / Sign up

Export Citation Format

Share Document