scholarly journals Pseudo-Outbreak of Imipenem-Resistant Acinetobacter baumannii Resulting from False Susceptibility Testing by a Rapid Automated System

2000 ◽  
Vol 38 (9) ◽  
pp. 3505-3507 ◽  
Author(s):  
Athanassios Tsakris ◽  
Anastassia Pantazi ◽  
Spyros Pournaras ◽  
Antonios Maniatis ◽  
Aleka Polyzou ◽  
...  

Introduction of the Vitek GNS-506 susceptibility testing cards in the Hippokration General Hospital, Thessaloniki, Greece, resulted in an apparently high prevalence of imipenem-resistant Acinetobacter baumannii. When 35 of these isolates were further tested by disk diffusion, broth microdilution, and agar dilution assays, 32 were imipenem sensitive by all tests and three were sensitive or intermediate, depending on the method. The pseudoresistant acinetobacters did not form a genetically homogeneous group. It is suggested that the detection of imipenem-resistant A. baumannii isolates by this system should be confirmed by an additional susceptibility test.

2007 ◽  
Vol 51 (10) ◽  
pp. 3726-3730 ◽  
Author(s):  
Jerome R. Lo-Ten-Foe ◽  
Anne Marie G. A. de Smet ◽  
Bram M. W. Diederen ◽  
Jan A. J. W. Kluytmans ◽  
Peter H. J. van Keulen

ABSTRACT Increasing antibiotic resistance in gram-negative bacteria has recently renewed interest in colistin as a therapeutic option. The increasing use of colistin necessitates the availability of rapid and reliable methods for colistin susceptibility testing. We compared seven methods of colistin susceptibility testing (disk diffusion, agar dilution on Mueller-Hinton [MH] and Isosensitest agar, Etest on MH and Isosensitest agar, broth microdilution, and VITEK 2) on 102 clinical isolates collected from patient materials during a selective digestive decontamination or selective oral decontamination trial in an intensive-care unit. Disk diffusion is an unreliable method to measure susceptibility to colistin. High error rates and low levels of reproducibility were observed in the disk diffusion test. The colistin Etest, agar dilution, and the VITEK 2 showed a high level of agreement with the broth microdilution reference method. Heteroresistance for colistin was observed in six Enterobacter cloacae isolates and in one Acinetobacter baumannii isolate. This is the first report of heteroresistance to colistin in E. cloacae isolates. Resistance to colistin in these isolates seemed to be induced upon exposure to colistin rather than being caused by stable mutations. Heteroresistant isolates could be detected in the broth microdilution, agar dilution, Etest, or disk diffusion test. The VITEK 2 displayed low sensitivity in the detection of heteroresistant subpopulations of E. cloacae. The VITEK 2 colistin susceptibility test can therefore be considered to be a reliable tool to determine susceptibility to colistin in isolates of genera that are known not to exhibit resistant subpopulations. In isolates of genera known to (occasionally) exhibit heteroresistance, an alternative susceptibility testing method capable of detecting heteroresistance should be used.


1997 ◽  
Vol 41 (1) ◽  
pp. 129-134 ◽  
Author(s):  
E L Fasola ◽  
S Bajaksouzian ◽  
P C Appelbaum ◽  
M R Jacobs

Susceptibilities of 124 strains of Streptococcus pneumoniae to erythromycin and clindamycin were determined by the National Committee for the Clinical Laboratory Standards (NCCLS) broth microdilution method, with incubation for 20 to 24 h in ambient air and with modifications of this method by incubation for up to 48 h in air and CO2. Strains were also tested by agar dilution, E-test, and disk diffusion; good correlation was obtained with these methods, with clear separation into bimodal populations of susceptible and resistant stains. The broth microdilution method, however, using incubation in air for 24 h (NCCLS method), misclassified 4 of 92 erythromycin-resistant strains (1 as susceptible and 3 as intermediate) and 25 of 58 clindamycin-resistant strains (all as susceptible). With the exception of one strain with clindamycin, susceptible and resistant strains were correctly classified by the microdilution method with incubation in CO2 for 24 h or in ambient air for 48 h. Disk diffusion, agar dilution, and E-test methods with incubation in 5% CO2 are therefore reliable methods for susceptibility testing of pneumococci against these agents. However, the NCCLS microdilution method, which specifies incubation for 20 to 24 h in ambient air, produced significant very major errors (43%) clindamycin. Modification of the microdilution method by incubation in 5% CO2 or by extension of incubation time in ambient air to 48 h corrected these errors. Disk diffusion, however, was shown to be a simple, convenient, and reliable method for susceptibility testing of pneumococci to erythromycin and clindamycin and is suggested as the method of choice for these agents.


2013 ◽  
Vol 57 (11) ◽  
pp. 5701-5703 ◽  
Author(s):  
María Díez-Aguilar ◽  
María-Isabel Morosini ◽  
Rosa del Campo ◽  
María García-Castillo ◽  
Javier Zamora ◽  
...  

ABSTRACTThe broth microdilution method for fosfomycin andPseudomonas aeruginosawas assessed and compared with the approved agar dilution method in 206 genetically unrelatedP. aeruginosaclinical isolates. Essential agreement between the two methods was 84%, and categorical agreement was 89.3%. Additionally, Etest and disk diffusion assays were performed. Results validate broth microdilution as a reliable susceptibility testing method for fosfomycin againstP. aeruginosa. Conversely, unacceptable concordance was established between Etest and disk diffusion results with agar dilution results.


2011 ◽  
Vol 55 (10) ◽  
pp. 4707-4711 ◽  
Author(s):  
Ana Elizabeth Markelz ◽  
Katrin Mende ◽  
Clinton K. Murray ◽  
Xin Yu ◽  
Wendy C. Zera ◽  
...  

ABSTRACTTheAcinetobacter baumannii-calcoaceticuscomplex (ABC) is associated with increasing carbapenem resistance, necessitating accurate resistance testing to maximize therapeutic options. We determined the accuracy of carbapenem antimicrobial susceptibility tests for ABC isolates and surveyed them for genetic determinants of carbapenem resistance. A total of 107 single-patient ABC isolates from blood and wound infections from 2006 to 2008 were evaluated. MICs of imipenem, meropenem, and doripenem determined by broth microdilution (BMD) were compared to results obtained by disk diffusion, Etest, and automated methods (the MicroScan, Phoenix, and Vitek 2 systems). Discordant results were categorized as very major errors (VME), major errors (ME), and minor errors (mE). DNA sequences encoding OXA beta-lactamase enzymes (blaOXA-23-like,blaOXA-24-like,blaOXA-58-like, andblaOXA-51-like) and metallo-β-lactamases (MBLs) (IMP, VIM, and SIM1) were identified by PCR, as was theKPC2carbapenemase gene. Imipenem was more active than meropenem and doripenem. The percentage of susceptibility was 37.4% for imipenem, 35.5% for meropenem, and 3.7% for doripenem. Manual methods were more accurate than automated methods.blaOXA-23-likeandblaOXA-24-likewere the primary resistance genes found.blaOXA-58-like, MBLs, andKPC2were not present. Both automated testing and manual testing for susceptibility to doripenem were very inaccurate, with VME rates ranging between 2.8 and 30.8%. International variability in carbapenem breakpoints and the absence of CLSI breakpoints for doripenem present a challenge in susceptibility testing.


1999 ◽  
Vol 37 (3) ◽  
pp. 544-547 ◽  
Author(s):  
Christine D. Steward ◽  
Sheila A. Stocker ◽  
Jana M. Swenson ◽  
Caroline M. O’Hara ◽  
Jonathan R. Edwards ◽  
...  

Fluoroquinolone resistance appears to be increasing in many species of bacteria, particularly in those causing nosocomial infections. However, the accuracy of some antimicrobial susceptibility testing methods for detecting fluoroquinolone resistance remains uncertain. Therefore, we compared the accuracy of the results of agar dilution, disk diffusion, MicroScan Walk Away Neg Combo 15 conventional panels, and Vitek GNS-F7 cards to the accuracy of the results of the broth microdilution reference method for detection of ciprofloxacin and ofloxacin resistance in 195 clinical isolates of the familyEnterobacteriaceae collected from six U.S. hospitals for a national surveillance project (Project ICARE [Intensive Care Antimicrobial Resistance Epidemiology]). For ciprofloxacin, very major error rates were 0% (disk diffusion and MicroScan), 0.9% (agar dilution), and 2.7% (Vitek), while major error rates ranged from 0% (agar dilution) to 3.7% (MicroScan and Vitek). Minor error rates ranged from 12.3% (agar dilution) to 20.5% (MicroScan). For ofloxacin, no very major errors were observed, and major errors were noted only with MicroScan (3.7% major error rate). Minor error rates ranged from 8.2% (agar dilution) to 18.5% (Vitek). Minor errors for all methods were substantially reduced when results with MICs within ±1 dilution of the broth microdilution reference MIC were excluded from analysis. However, the high number of minor errors by all test systems remains a concern.


2020 ◽  
Vol 58 (10) ◽  
Author(s):  
Hanna Hakvoort ◽  
Evelyn Bovenkamp ◽  
Kerryl E. Greenwood-Quaintance ◽  
Suzannah M. Schmidt-Malan ◽  
Jay N. Mandrekar ◽  
...  

ABSTRACT This study aimed to determine whether agar dilution, research-use-only disk diffusion (Mast Group Ltd., Bootle Merseyside, UK), Etest (bioMérieux, Inc., Durham, NC), and MIC test strip (MTS) (Liofilchem, Inc., Waltham, MA) methods yield equivalent results to those of broth microdilution (BMD) for imipenem-relebactam susceptibility testing using a collection of 297 Gram-negative bacilli, including members of the order Enterobacterales and Pseudomonas aeruginosa, enriched for drug resistance. MIC and disk diameter results were interpreted using United States Food and Drug Administration breakpoints. Overall, 76.8% of the isolates tested were susceptible to imipenem-relebactam by BMD. MIC values for agar dilution, Etest, and MTS were not significantly different from that for BMD, although they tended to be 1 to 2 dilutions higher. Essential agreement was 95.6% for agar dilution, 90.6% for Etest, and 85.2% for MTS. Categorical agreement was 98.0% for agar dilution, 73.1% for disk diffusion, 96.3% for Etest, and 96.6% for MTS. In conclusion, agar dilution and Etest yielded comparable results to BMD for imipenem-relebactam.