Bubble versus other continuous positive airway pressure forms: a systematic review and meta-analysis

Author(s):  
Shruti K Bharadwaj ◽  
Abdullah Alonazi ◽  
Laura Banfield ◽  
Sourabh Dutta ◽  
Amit Mukerji

BackgroundUse of bubble continuous positive airway pressure (CPAP) has generated considerable interest in neonatal care, but its comparative effectiveness compared with other forms of CPAP, especially in developed countries, remains unclear.ObjectiveTo systematically review and meta-analyse short-term clinical outcomes among preterm infants treated with bubble CPAP vs all other forms of CPAP.MethodsProspective experimental studies published from 1995 onward until October 2018 comparing bubble versus other CPAP forms in preterm neonates <37 weeks’ gestational age were included after a systematic review of multiple databases using pre-specified search criteria.ResultsA total of 978 articles were identified, of which 19 articles were included in meta-analyses. Of these, 5 had a high risk of bias, 8 had unclear risk and 6 had low risk. The risk of the primary outcome (CPAP failure within 7 days) was lower with bubble CPAP (0.75; 95% CI 0.57 to 0.98; 12 studies, 1194 subjects, I2=21%). Among secondary outcomes, only nasal injury was higher with use of bubble CPAP (risk ratio (RR) 2.04, 95% CI 1.33 to 3.14; 9 studies, 983 subjects; I2=42%) whereas no differences in mortality (RR 0.82, 95% CI 0.47 to 1.92; 9 studies, 1212 subjects, I2=20%) or bronchopulmonary dysplasia (BPD) (RR 0.8, 95% CI 0.53 to 1.21; 8 studies, 816 subjects, I2=0%) were noted.ConclusionBubble CPAP may lead to lower incidence of CPAP failure compared with other CPAP forms. However, it does not appear to translate to improvement in mortality or BPD and potential for nasal injury warrants close monitoring during clinical application.Trial registration numberCRD42019120411.

2019 ◽  
Vol 24 (Supplement_2) ◽  
pp. e59-e59
Author(s):  
Shruthi Bharadwaj ◽  
Abdullah Alonazi ◽  
Laura Banfield ◽  
Sourabh Dutta ◽  
Amit Mukerjee

2021 ◽  
pp. archdischild-2021-323041
Author(s):  
Kristen L Sessions ◽  
Andrew G Smith ◽  
Peter J Holmberg ◽  
Brian Wahl ◽  
Tisungane Mvalo ◽  
...  

ObjectiveDetermine non-invasive ventilation with continuous positive airway pressure (CPAP) outcomes for paediatric respiratory distress in low-income and middle-income countries (LMICs).DesignSystematic review and meta-analysis.SettingLMIC hospitals.PatientsOne month to 15 year olds with respiratory distress.InterventionsWe searched Medline, Embase, LILACS, Web of Science and Scopus on 7 April 2020. Included studies assessed CPAP safety, efficacy or effectiveness. All study types were included; neonatal only studies were excluded. Data were extracted by two reviewers and bias was assessed. Certainty of evidence was evaluated, and risk ratios (RR) were produced for meta-analyses. (PROSPERO protocol CRD42018084278).Results2174 papers were screened, 20 were included in the systematic review and 3 were included in two separate meta-analyses of mortality and adverse events. Studies suitable for meta-analysis were randomised controlled trials (RCTs) from Bangladesh, Ghana and Malawi. For meta-analyses comparing death or adverse events between CPAP and low-flow oxygen recipients, we found no clear CPAP effect on mortality (RR 0.75, 95% CI 0.33 to 1.72) or adverse events (RR 1.52, CI 0.71 to 3.26). We downgraded the certainty of evidence for both death and adverse events outcomes to ‘low’ due to design issues and results discrepancies across RCTs.ConclusionsEvidence for CPAP efficacy against mortality and adverse events has low certainty and is context dependent. Hospitals introducing CPAP need to have mechanisms in place to optimise safety in the context it is being used; this includes the location (a high dependency or intensive care area), adequate numbers of staff trained in CPAP use, close monitoring and mechanisms for escalation, daily direct physician supervision, equipment that is age appropriate and user-friendly and continuous monitoring of outcomes and quality of care.


BMJ Open ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. e044499
Author(s):  
Fanny Bertelli ◽  
Carey Meredith Suehs ◽  
Jean Pierre Mallet ◽  
Marie Caroline Rotty ◽  
Jean Louis Pepin ◽  
...  

Introduction To date, continuous positive airway pressure (CPAP) remains the cornerstone of obstructive sleep apnoea treatment. CPAP data describing residual sleep-disordered breathing events (ie, the CPAP-measured apnoea–hypopnoea indices (AHI-CPAPflow)) is difficult to interpret because it is an entirely different metric than the polysomnography (PSG) measured AHI gold standard (AHI-PSGgold). Moreover, manufacturer definitions for apnoea and hypopnoea are not only different from those recommended for PSG scoring, but also different between manufacturers. In the context of CPAP initiation and widespread telemedicine at home to facilitate sleep apnoea care, there is a need for concrete evidence that AHI-CPAPflow can be used as a surrogate for AHI-PSGgold. Methods and analysis No published systematic review and meta-analysis (SRMA) has compared the accuracy of AHI-CPAPflow against AHI-PSGgold and the primary objective of this study is therefore to do so using published data. The secondary objectives are to similarly evaluate other sleep disordered breathing indices and to perform subgroup analyses focusing on the inclusion/exclusion of central apnoea patients, body mass index levels, CPAP device brands, pressure titration modes, use of a predetermined and fixed pressure level or not, and the impact of a 4% PSG desaturation criteria versus 3% PSG on accuracy. The Preferred Reporting Items for SRMA protocols statement guided study design. Randomised controlled trials and observational studies of adult patients (≥18 years old) treated by a CPAP device will be included. The CPAP intervention and PSG comparator must be performed synchronously. PSGs must be scored manually and follow the American Academy of Sleep Medicine guidelines (2007 AASM criteria or more recent). To assess the risk of bias in each study, the Quality Assessment of Diagnostic Accuracy Studies 2 tool will be used. Ethics and dissemination This protocol received ethics committee approval on 16 July 2020 (IRB_MTP_2020_07_2020000404) and results will be disseminated via peer-reviewed publications. PROSPERO/Trial registration numbers CRD42020159914/NCT04526366; Pre-results


Author(s):  
Bayane Sabsabi ◽  
Ava Harrison ◽  
Laura Banfield ◽  
Amit Mukerji

Objective The study aimed to systematically review and analyze the impact of nasal intermittent positive pressure ventilation (NIPPV) versus continuous positive airway pressure (CPAP) on apnea of prematurity (AOP) in preterm neonates. Study Design In this systematic review and meta-analysis, experimental studies enrolling preterm infants comparing NIPPV (synchronized, nonsynchronized, and bi-level) and CPAP (all types) were searched in multiple databases and screened for the assessment of AOP. Primary outcome was AOP frequency per hour (as defined by authors of included studies). Results Out of 4,980 articles identified, 18 studies were included with eight studies contributing to the primary outcome. All studies had a high risk of bias, with significant heterogeneity in definition and measurement of AOP. There was no difference in AOPs per hour between NIPPV versus CPAP (weighted mean difference = −0.19; 95% confidence interval [CI]: −0.76 to 0.37; eight studies, 456 patients). However, in a post hoc analysis evaluating the presence of any AOP (over varying time periods), the pooled odds ratio (OR) was lower with NIPPV (OR: 0.46; 95% CI: 0.32–0.67; 10 studies, 872 patients). Conclusion NIPPV was not associated with decrease in AOP frequency, although demonstrated lower odds of developing any AOP. However, definite recommendations cannot be made based on the quality of the published evidence. Key Points


Neonatology ◽  
2021 ◽  
Vol 118 (3) ◽  
pp. 264-273
Author(s):  
Anne Lee Solevåg ◽  
Po-Yin Cheung ◽  
Georg M. Schmölzer

<b><i>Background:</i></b> Bi-level noninvasive ventilation (NIV) has been used in respiratory distress syndrome (RDS) as primary treatment, post-extubation, and to treat apnea. This review summarizes studies on bi-level NIV in premature infants with RDS. Nonsynchronized nasal intermittent positive pressure ventilation (nsNIPPV) and synchronized NIPPV (SNIPPV) use pressure settings ≥ those used during mechanical ventilation (MV), and biphasic continuous positive airway pressure (BiPAP) use two nasal continuous positive airway pressure (NCPAP) levels ≤4 cm H<sub>2</sub>O apart. <b><i>Methods:</i></b> A systematic review (Medline OVID and Pubmed) and meta-analysis of randomized controlled trials. Primary outcomes were bronchopulmonary dysplasia (BPD) and mortality. Secondary outcomes included NIV failure (intubation) and extubation failure (re-intubation). Data were pooled using a fixed-effects model to calculate the relative risk (RR) with 95% confidence interval (CI) between NIV modes (RevMan v 5.3, Copenhagen, Denmark). <b><i>Results:</i></b> Twenty-four randomized controlled trials that largely did not correct for mean airway pressure (MAP) and used outdated ventilators were included. Compared with NCPAP, both nsNIPPV and SNIPPV resulted in less re-intubation (RR 0.88 with 95% CI (0.80, 0.97) and RR 0.20 (0.10, 0.38), respectively) and BPD (RR 0.69 (0.49, 0.97) and RR 0.51 (0.29, 0.88), respectively). nsNIPPV also resulted in less intubation (RR 0.57 (0.45, 0.73) versus NCPAP, with no difference in mortality. One study showed less intubation in BiPAP versus NCPAP. <b><i>Conclusions:</i></b> Bi-level NIV versus NCPAP may reduce MV and BPD in premature infants with RDS. Studies comparing equivalent MAP utilizing currently available machines are needed.


2009 ◽  
Vol 17 (4) ◽  
pp. 489-494 ◽  
Author(s):  
Renata Medeiros do Nascimento ◽  
Anne Laura Costa Ferreira ◽  
Ana Cláudia Ferreira Pinheiro Coutinho ◽  
Regina Célia Sales Santos Veríssimo

Continuous positive airway pressure (CPAP) with prongs is the ventilatory support most used in newborns. Nasal injuries are complications that may arise due to the prolonged use of this device. This study aimed to determine the frequency of nasal injuries in newborns through the use of continuous positive airway pressure with prongs. A convenience sample composed of hospitalized newborns using prongs for more than two days was used. Data were collected through a structured form. Lesions were observed in all newborns, which were classified as: mild (79.6%), moderate (19.7%) and severe (0.7%). The conclusion is that the use of prongs for more than two days represents a risk factor for the lesions to develop.