OCT angiography in optic disc drusen: comparison with structural and functional parameters

2019 ◽  
Vol 104 (8) ◽  
pp. 1109-1113 ◽  
Author(s):  
Hendrik Engelke ◽  
Mehdi Shajari ◽  
Julian Riedel ◽  
Niklas Mohr ◽  
Siegfried G Priglinger ◽  
...  

BackgroundOptic disc drusen (ODD) can cause retinal nerve fibre layer (RNFL) defects with progressive visual field (VF) loss. Microvascular changes are discussed as a cause. We measured the vessel density (VD) of the optic disc in ODD using optical coherence tomography angiography and compared it with a normal population. Another intent was to determine the sensitivity and correlations in comparison with functional (VF) and structural parameters (RNFL, minimum rim width (MRW), ganglion cell complex (GCC)).MethodsWe analysed the VD of 25 patients with ODD and an age-matched control population including 25 healthy participants using AngioVue (Optovue, Fremont, CA, USA). We obtained data about RNFL, GCC, Bruch’s membrane opening MRW (Spectralis HRA & OCT; Heidelberg Engineering, Germany) and VF (standard automated perimetry; SITA 24-2). Low image quality and pathologies interfering with the diagnostics were excluded. Parametric data were analysed using the t-test and non-parametric values using the Mann-Whitney U test. Linear regression analysis was used to determine correlations using the Bravais-Pearson test.ResultsThe VD was significantly reduced in the ODD group especially the peripapillary capillary VD (n=45 vs 50 eyes; mean 43.15% vs 51.70%). Peripapillary RNFL thickness correlated with the VD significantly (r=0.902 (n=44), 0.901 (n=44), 0.866 (n=45)). The RNFL analysis showed a reduction in ODD, especially the superior hemisphere (mean 107 µm, 129 µm; 49 vs 50 eyes). The GCC was significantly lower in the ODD group (n=38 vs 40; mean 87 µm vs 98 µm). Positive correlation between the VD and the GCC was significant (n=37, r=0.532). There is a significant negative correlation (n=19; r=−0.726) between the VD and the pattern standard deviation (PSD).ConclusionThis study reveals significant peripapillary microvascular changes in patients with ODD correlating with the RNFL and GCC reduction. There is a negative correlation between the PSD and the VD.

Author(s):  
Barbara Cvenkel ◽  
Maja Sustar ◽  
Darko Perovšek

Abstract Purpose To investigate the value of pattern electroretinography (PERG) and photopic negative response (PhNR) in monitoring glaucoma compared to standard clinical tests (standard automated perimetry (SAP) and clinical optic disc assessment) and structural measurements using spectral-domain OCT. Methods A prospective study included 32 subjects (32 eyes) with ocular hypertension, suspect or early glaucoma monitored for progression with clinical examination, SAP, PERG, PhNR and OCT for at least 4 years. Progression was defined clinically by the documented change of the optic disc and/or significant visual field progression (EyeSuite™ trend analysis). One eye per patient was included in the analysis. Results During the follow-up, 13 eyes (40.6%) showed progression, whereas 19 remained stable. In the progressing group, all parameters showed significant worsening over time, except for the PhNR, whereas in the stable group only the OCT parameters showed a significant decrease at the last visit. The trend of change over time using linear regression was steepest for the OCT parameters. At baseline, only the ganglion cell complex (GCC) and peripapillary retinal nerve fibre (pRNFL) thicknesses significantly discriminated between the stable and progressing eyes with the area under the ROC curve of 0.72 and 0.71, respectively. The inter-session variability for the first two visits in the stable group was lower for OCT (% limits of agreement within ± 17.4% of the mean for pRNFL and ± 3.6% for the GCC thicknesses) than for ERG measures (within ± 35.9% of the mean for PERG N95 and ± 59.9% for PhNR). The coefficient of variation for repeated measurements in the stable group was 11.9% for PERG N95 and 23.6% for the PhNR, while it was considerably lower for all OCT measures (5.6% for pRNFL and 1.7% for GCC thicknesses). Conclusions Although PERG and PhNR are sensitive for early detection of glaucomatous damage, they have limited usefulness in monitoring glaucoma progression in clinical practice, mainly due to high inter-session variability. On the contrary, OCT measures show low inter-session variability and might have a predicting value for early discrimination of progressing cases.


PLoS ONE ◽  
2021 ◽  
Vol 16 (2) ◽  
pp. e0247399
Author(s):  
Edyta Koman-Wierdak ◽  
Katarzyna Nowomiejska ◽  
Agnieszka Brzozowska ◽  
Dominika Nowakowska ◽  
Mario Damiano Toro ◽  
...  

The aim of the study is to evaluate the progression of visual field (VF) defects over 16 years of observation and to assess abnormalities in vessels and retinal nerve fibre layer (RNFL) thickness in patients with optic disc drusen (ODD). Both static automated perimetry (SAP) and semi-automated kinetic perimetry (SKP) were performed in 16 eyes of 8 patients (mean age 54 years) with ODD among 26 eyes of 13 patients examined 16 years before. The area of I2e, I4e, III4e, and V4e isopters was measured in deg2. The MD and PSD parameters were estimated using SAP. Optical coherence tomography angiography (OCT-A) was additionally performed in 16 ODD eyes and 16 eyes of 8 healthy subjects to estimate the RNFL thickness and vessel density of the optic nerve disc and the macula. The differences in all isopter areas of SKP and SAP parameters after 16 years were not significant. The analysis of OCT-A showed a significant reduction of the vessel density and RNFL of the peripapillary area in each segment in patients with ODD, compared with the control group. The highest reduction of RNFL was observed in the superior segment of the optic disc area (92.56μm vs 126.63μm) also the macular thickness was decreased in ODD patients, compared with the control group. In the macula, there was a significant vascular defect in the whole superficial layer and in the parafoveal deep layer. A strong significant correlation of the parafoveal deep plexus with MD and PSD parameters was detected. In conclusion, VF loss due to ODD after 16 years of the follow-up was not significant both in SKP and SAP. ODD caused a reduced vessel density and RNFL, as well as macular thickness in OCT-A. SAP parameters were influenced by parafoveal deep plexus.


2021 ◽  
Vol 8 ◽  
Author(s):  
Yali Wu ◽  
Qing Cun ◽  
Yijin Tao ◽  
Wenyan Yang ◽  
Jia Wei ◽  
...  

Purpose: To investigate the clinical significance of macular estimated retinal ganglion cell (mRGC) and estimated retinal ganglion cell (eRGC) in the diagnosis and staging of glaucoma.Methods: This is a cross-section study. All enrolled subjects underwent standard automated perimetry (SAP) and optical coherence tomography (OCT) examination. Swedish Interactive Threshold Algorithm (SITA)-FAST detection strategy and 24-2, 10-2 detection programs were employed in SAP assessment. The visual-field parameters and OCT parameters were calculated according to three formulas to obtain the eRGC and mRGC1 or mRGC2. The efficiency of eRGC, mRGC1, and mRGC2 estimates for the staging of glaucoma was compared. The sensitivity and specificity of each parameter for diagnosis of glaucoma were analyzed using the receiver operating characteristic (ROC) curve.Results: A total of 119 eyes were included in the analysis. Compared with the healthy controls, eRGC, mRGC1, and mRGC2 estimates were significantly decreased in patients with glaucoma. As glaucoma progressed, eRGC, mRGC1, and mRGC2 estimates were gradually reduced. In preperimetric glaucoma, mRGC1, mRGC2, and eRGC were reduced by 13.2, 14.5, and 18%, respectively. In the mild stage of glaucoma, mRGC1, mRGC2, and eRGC were reduced by 28, 34, and 38%, respectively. In the advanced stage of glaucoma, mRGC1, mRGC2, and eRGC were reduced by 81, 85, and 92% respectively. The proportion of retinal ganglion cell (RGC) loss in the macula was close to that outside the macula. The specificity at 95% gave a sensitivity of 95.51, 86.52, and 87.64% for eRGC, mRGC1, and mRGC2, respectively. The sensitivity of structural parameters macular ganglion cell complex thickness and retinal nerve fiber layer (RNFL) were 98.88 and 95.51%, respectively. The sensitivity of functional parameters mean deviation (24-2) and visual field index (VFI) were 80.90 and 73.03%, respectively. The area under ROC curve of mRGC1, mRGC2, and eRGC were 0.982, 0.972, and 0.995 (P < 0.0001), respectively.Conclusion: Estimated retinal ganglion cell, mRGC1, and mRGC2 provide value to the staging of glaucoma and better diagnostic performance. Macular RGC estimatesthat integration of both structural and functional damages in macular may serve as a sensitive indicator for assessing macular damage in glaucoma and are of importance for the diagnosis and progression management of glaucoma.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yoko Mase ◽  
Yoshitsugu Matsui ◽  
Eriko Uchiyama ◽  
Hisashi Matsubara ◽  
Masahiko Sugimoto ◽  
...  

Abstract Background Acquired color anomalies caused by cerebral trauma are classified as either achromatopsias or dyschromatopsias (Zeki, Brain 113:1721–1777, 1990). The three main brain regions stimulated by color are V1, the lingual gyrus, which was designated as human V4 (hV4), and the fusiform gyrus, designated as V4α. (Zeki, Brain 113:1721–1777, 1990). An acquired cerebral color anomaly is often accompanied by visual field loss (hemi- and quadrantanopia), facial agnosia, prosopagnosia, visual agnosia, and anosognosia depending on the underlying pathology (Bartels and Zeki, Eur J Neurosci 12:172–193, 2000), (Meadows, Brain 97:615–632, 1974), (Pearman et al., Ann Neurol 5:253–261, 1979). The purpose of this study was to determine the characteristics of a patient who developed dyschromatopsia following a traumatic injury to her brain. Case presentation The patient was a 24-year-old woman who had a contusion to her right anterior temporal lobe. After the injury, she noticed color distortion and that blue objects appeared green in the left half of the visual field. Although conventional color vision tests did not detect any color vision abnormalities, short wavelength automated perimetry (SWAP) showed a decrease in sensitivity consistent with a left hemi-dyschromatopsia. Magnetic resonance imaging (MRI) detected abnormalities in the right fusiform gyrus, a part of the anterior temporal lobe. At follow-up 14 months later, subjective symptoms had disappeared, but the SWAP abnormalities persisted and a thinning of the sectorial ganglion cell complex (GCC) was detected. Conclusion The results indicate that although the subjective symptoms resolved early, a reduced sensitivity of SWAP remained and the optical coherence tomography (OCT) showed GCC thinning. We conclude that local abnormalities in the anterior section of fusiform gyrus can cause mild cerebral dyschromatopsia without other symptoms. These findings indicate that it is important to listen to the symptoms of the patient and perform appropriate tests including the SWAP and OCT at the early stage to objectively prove the presence of acquired cerebral color anomaly.


2011 ◽  
Vol 2 (2) ◽  
pp. 232-237
Author(s):  
Tryfon Rotsos ◽  
Chrysanthos Symeonidis ◽  
Mrinal Rana ◽  
James S. Deane

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alexandru Lavric ◽  
Valentin Popa ◽  
Hidenori Takahashi ◽  
Rossen M. Hazarbassanov ◽  
Siamak Yousefi

AbstractThe main goal of this study is to identify the association between corneal shape, elevation, and thickness parameters and visual field damage using machine learning. A total of 676 eyes from 568 patients from the Jichi Medical University in Japan were included in this study. Corneal topography, pachymetry, and elevation images were obtained using anterior segment optical coherence tomography (OCT) and visual field tests were collected using standard automated perimetry with 24-2 Swedish Interactive Threshold Algorithm. The association between corneal structural parameters and visual field damage was investigated using machine learning and evaluated through tenfold cross-validation of the area under the receiver operating characteristic curves (AUC). The average mean deviation was − 8.0 dB and the average central corneal thickness (CCT) was 513.1 µm. Using ensemble machine learning bagged trees classifiers, we detected visual field abnormality from corneal parameters with an AUC of 0.83. Using a tree-based machine learning classifier, we detected four visual field severity levels from corneal parameters with an AUC of 0.74. Although CCT and corneal hysteresis have long been accepted as predictors of glaucoma development and future visual field loss, corneal shape and elevation parameters may also predict glaucoma-induced visual functional loss.


2012 ◽  
Vol 4 (2) ◽  
pp. 236-241
Author(s):  
S Ganekal

Objective: To compare the macular ganglion cell complex (GCC) with peripapillary retinal fiber layer (RNFL) thickness map in glaucoma suspects and patients. Subjects and methods: Forty participants (20 glaucoma suspects and 20 glaucoma patients) were enrolled. Macular GCC and RNFL thickness maps were performed in both eyes of each participant in the same visit. The sensitivity and specificity of a color code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Standard Automated Perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. Statistics: The statistical analysis was performed with the SPSS 10.1 (SPSS Inc. Chicago, IL, EUA). Results were expressed as mean ± standard deviation and a p value of 0.05 or less was considered significant. Results: Provide absolute numbers of these findings with their units of measurement. There was a statistically significant difference in average RNFL thickness (p=0.004), superior RNFL thickness (p=0.006), inferior RNFL thickness (p=0.0005) and average GCC (p=0.03) between the suspects and glaucoma patients. There was no difference in optic disc area (p=0.35) and vertical cup/disc ratio (p=0.234) in both groups. While 38% eyes had an abnormal GCC and 13% had an abnormal RNFL thickness in the glaucoma suspect group, 98% had an abnormal GCC and 90% had an abnormal RNFL thickness in the glaucoma group.Conclusion: The ability to diagnose glaucoma with macular GCC thickness is comparable to that with peripapillary RNFL thickness. Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma.DOI: http://dx.doi.org/10.3126/nepjoph.v4i2.6538 Nepal J Ophthalmol 2012; 4 (2): 236-241 


2021 ◽  
pp. 039156032110637
Author(s):  
Valerio Di Paola ◽  
Angelo Totaro ◽  
Giacomo Avesani ◽  
Benedetta Gui ◽  
Andrea Boni ◽  
...  

Purpose: Our aim was to explore the relation between FA and ADC, number and length of the periprostatic neurovascular fibers (PNF) by means of 1.5 T Diffusion Tensor Imaging (DTI) imaging through a multivariate linear regression analysis model. Methods: For this retrospective study, 56 patients (mean age 63.5 years), who underwent 1.5-T prostate MRI, including DTI, were enrolled between October 2014 and December 2018. Multivariate regression analysis was performed to evaluate the statistically significant correlation between FA values (dependent variable) and ADC, the number and the length of PNF (independent variables), if p-value <0.05. A value of 0.5 indicated poor agreement; 0.5–0.75, moderate agreement; 0.75–0.9, good agreement; 0.61–0.80, good agreement; and 0.9–1.00, excellent agreement. Results: The overall fit of the multivariate regression model was excellent, with R2 value of 0.9445 ( R2 adjusted 0.9412; p < 0.0001). Multivariate linear regression analysis showed a statistically significant correlation ( p < 0.05) for all the three independent variables. The r partial value was −0.9612 for ADC values ( p < 0.0001), suggesting a strong negative correlation, 0.4317 for the number of fiber tracts ( p < 0.001), suggesting a moderate positive correlation, and −0.306 for the length of the fiber tracts ( p < 0.05), suggesting a weak negative correlation. Conclusions: Our multivariate linear regression model has demonstrated a statistically significant correlation between FA values of PNF with other DTI parameters, in particular with ADC.