Seismic response of two-storey buildings with concentrically braced steel frames

1999 ◽  
Vol 26 (4) ◽  
pp. 497-509 ◽  
Author(s):  
M S Medhekar ◽  
DJL Kennedy

The seismic performance of two-storey steel buildings with concentrically braced frames as the lateral load resisting system is evaluated. The buildings are designed in accordance with the National Building Code of Canada (1995) and CSA Standard S16.1-94 for five seismic zones in western Canada. Only frames designed with a force modification factor of 1.5 are considered. Analytical models of the buildings are developed, which consider the nonlinear seismic behaviour of the concentrically braced frame, the shear strength of the roof diaphragm, and the stiffness and strength contributions of the nonstructural partitions. The seismic response is estimated with nonlinear static and dynamic time history analyses. Roof diaphragm flexibility does not influence the dynamic behaviour significantly. The distribution of lateral forces from response spectrum analysis agrees well with that specified. Current design procedures provide reasonable estimates of the lateral drift in low and moderate seismic zones. Brace ductility demands are reasonable and may be limited due to the contributions of nonstructural partitions. However, in moderate and high seismic zones, the connections, beams, columns, and roof diaphragm are overloaded. The capacity design procedure is recommended to provide adequate resistance to the overloaded components.Key words: analyses, capacity design, concentrically braced frame, diaphragm, dynamic, earthquake, low-rise, nonlinear, seismic design, steel.

1999 ◽  
Vol 26 (4) ◽  
pp. 379-394 ◽  
Author(s):  
M S Medhekar ◽  
DJL Kennedy

The seismic performance of single-storey steel buildings, with concentrically braced frames and a roof diaphragm that acts structurally, is evaluated. The buildings are designed in accordance with the National Building Code of Canada 1995 and CSA Standard S16.1-94 for five seismic zones in western Canada with seismicities ranging from low to high. Only frames designed with a force modification factor of 1.5 are considered. Analytical models of the building are developed, which consider the nonlinear seismic behaviour of the concentrically braced frame, the strength and stiffness contributions of the cladding, and the flexibility, strength, and distributed mass of the roof diaphragm. The seismic response of the models is assessed by means of a linear static analysis, a response spectrum analysis, a nonlinear static or "pushover" analysis, and nonlinear dynamic time history analyses. The results indicate that current design procedures provide a reasonable estimate of the drift and brace ductility demand, but do not ensure that yielding is restricted to the braces. Moreover, in moderate and high seismic zones, the roof diaphragm responds inelastically and brace connections are overloaded. Recommendations are made to improve the seismic performance of such buildings.Key words: analyses, concentrically braced frame, dynamic, earthquake, flexible diaphragm, low-rise, nonlinear, seismic design, steel.


2018 ◽  
Vol 4 (3) ◽  
pp. 655 ◽  
Author(s):  
Ali Kachooee ◽  
Mohammad Ali Kafi ◽  
Mohsen Gerami

The concentrically braced frames (CBFs) are one of the most widely used lateral load-resisting systems. Seismic performance of these structures has a weakness that is due to the brace buckling at a lower loading than the ultimate compressive loading capacity. In this paper, attempt is made to enhance the seismic response of CBFs through utilizing a local fuse. For this purpose, first the formulation of fuse area and length are presented. Then based on this formulation, several numerical models have been built and analyzed to examine the effect of implementing this fuse on seismic response of CBFs. From the analyses results, it is found that if the reduced cross-section fuse (RCF) is properly designed and also the end of brace is fixed, the CBFs with equal energy dissipation capacity, that are equipped with this fuse exhibit a better ductility than the customary CBFs.


Author(s):  
Nasim Irani Sarand ◽  
Abdolrahim Jalali

Concentrically braced frames (CBFs) as one of well-known stiff and common lateral force resisting systems often show limited ductility capacity under severe earthquakes. This study proposes rocking zipper braced frame (RZBF) to improve the drift capacity of CBFs which is based on combination of rocking behavior and zipper columns. In the RZBF system, rocking behavior permit the braced frame to uplift during the earthquake and then restoring force induced through post-tensioned bars self-center the frame to its initial state. Also, zipper columns can decrease the concentration of damage by distributing the unbalance force at the mid bay over the frame’s height. To assess the performance of RZBF, a comparison study is carried out considering CBF, rocking concentrically braced frame, zipper braced frame and RZBF. For this purpose, some frames structures are designed and nonlinear time history analysis conduct under a set of earthquake records. Seismic responses such as roof drift ratio, gap opening at the column-base interface, forces of top story braces and post-tensioned bars are taken into consideration. The results show that the proposed RZBF has better performance among the others and zipper columns can improve the behavior of rocking systems.


2018 ◽  
Vol 141 (1) ◽  
Author(s):  
Roberto Javier Merino Vela ◽  
Emanuele Brunesi ◽  
Roberto Nascimbene

Nonstructural components play an important role in the correct functioning of industrial facilities, which may suffer greatly from earthquake-induced actions, as demonstrated by past seismic events. Therefore, the correct evaluation of seismic demands acting upon them is of utmost importance when assessing or designing an industrial complex exposed to seismic hazard. Among others, nonlinear time history analyses (NLTHA) of structural systems including nonstructural elements and floor response spectra are well-known methods for computing these actions, the former being more accurate and the latter being less onerous. This work focuses on deriving floor spectra for a steel special concentrically braced frame (SCBF), which is a common type of lateral-load resisting system for industrial frames. The results are used to compute the seismic actions on a small liquid storage tank mounted on the case study frame. Additionally, the results are compared to those obtained by modeling the structure and the tank together, that is, by modeling the tank explicitly and incorporating it within the model of the support structure. To this end, a simple model, consisting of two uncoupled single degree-of-freedom systems, is used for the tank. The floor spectra resulting from both approaches are compared to establish differences in the behavior of the structure and nonstructural element/component. Finally, the seismic demand on the tank—obtained by direct and indirect analyses—is compared to that obtained by applying ASCE 7-10 and Eurocode 8 prescriptions.


2016 ◽  
Vol 20 (6) ◽  
pp. 940-952 ◽  
Author(s):  
Bing Qu ◽  
Francisco Sanchez-Zamora ◽  
Michael Pollino ◽  
Hetao Hou

This article focuses on evaluating the adequacy of a seismic rehabilitation technology which adds rocking cores to deficient steel concentrically braced frames in near-fault regions. Two demonstration buildings were rehabilitated with the technology. Seismic performance of the rehabilitated buildings was evaluated through numerical simulations. Analysis results suggest that the code-compliant concentrically braced frames may be vulnerable to collapse under the fault-normal components of the near-fault ground motions, approximately having a probability of exceedance of 10% in 50 years. It is found that the Rocking Core technology is effective in reducing the inter-story drift responses of the demonstration buildings under near-fault earthquakes. The rehabilitated systems can further benefit from the use of hysteretic energy dissipating links between the rocking cores and existing concentrically braced frames. This article also addresses the influence of the rocking cores on modal properties of the rehabilitated buildings. It is found that the rocking core with moderate stiffness does not significantly alter the modal properties of a rehabilitated concentrically braced frame.


2016 ◽  
Vol 847 ◽  
pp. 128-134
Author(s):  
Zhi Hao Zhou ◽  
Camillo Nuti ◽  
Davide Lavorato ◽  
Alessandro Vittorio Bergami

In this paper, a new model named as “brace01” for steel brace is presented on the basis of experimental data on different types of steel struts. This model shows a peasant capability in the structural analysis of Concentrically Braced Frames. A brace is idealized as a pin-ended member with a plastic hinge located at its midspan. This expression of the model is proposed by combining the mechanical properties and the phenomenological characters. The model for steel brace is implemented in an effective way in OpenSees. The calibration of the material model is done by comparing the numerical curves generated by the numerical model with the experimental curves of pin-ended steel braces. The new model is proved applicable to practical Concentrically Braced Frame.


2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Ergang Xiong ◽  
Kun Zu ◽  
Qian Zhang

To study the seismic performance of self-centering concentrically braced frame (SC-CBF) structure, the static elastoplastic analysis, low-cycle repeated loading analysis, and elastoplastic time-history analysis were conducted for a four-story SC-CBF structure, compared with the traditionally concentrically braced frame (CBF) structure. The influences of different GAP stiffnesses and cross-sectional areas of prestressed tendon were investigated on the self-centering and seismic performance of the SC-CBF structure. The results show that the SC-CBF structure has a strong lateral resistance, a small base shear under earthquake action, and a slight residual drift after unloading. The SC-CBF structure has a better ductility than the CBF structure. The displacement of the SC-CBF structure under the action of rare and extremely rare earthquakes is large, and the structure can dissipate more energy; the interstory drift is large, but the residual drift is small, exhibiting its ideal seismic and self-centering performance. However, the mechanical behavior of prestressed tendons is significantly affected by the stiffness of the GAP. The mechanical and seismic performances of the overall structure are slightly affected by the stiffness of the GAP, but the cross-sectional area of the prestressed tendons has a remarkable influence on the overall performance of the structure.


2018 ◽  
Vol 763 ◽  
pp. 157-164
Author(s):  
Vahid Mohsenzadeh ◽  
Lydell D.A. Wiebe

Concentrically braced frames are one of the most common seismic force resisting systems because of their high strength and stiffness. In current practice, the gusset plates that connect the brace to the adjacent beams and columns can increase the strength and stiffness of the connection significantly. This strength and stiffness can provide a reserve of lateral force resisting capacity during a large earthquake, which may play a role in the seismic collapse behaviour of the braced frame. An alternative connection has recently been proposed as a means of ensuring that brace buckling occurs only in-plane, that no field welding is required, and that all damage is confined to a replaceable brace module. However, the proposed connection does not include a gusset plate that can provide a similar stiffness and reserve capacity. In order to investigate the potential influence of the range of possible beam-column-gusset plate designs, this paper assesses the effect of the fixity of these connections on the behavior of a six-storey special concentrically braced frame. Nonlinear dynamic analyses have been conducted to determine the seismic performance of the frame with this connection modelled using three different assumptions (pinned, shear tab and fixed), and the collapse risk is assessed using the FEMA P695 methodology. The results show that when the gravity framing is not modelled, the fixity of the beam-column connections is important in avoiding the formation of a soft storey under extreme earthquakes, thereby reducing the probability of collapse of the building.