STRUCTURAL AND OPTICAL FEATURES OF POROUS SILICON PREPARED BY ELECTROCHEMICAL ANODIC ETCHING

2009 ◽  
Vol 16 (01) ◽  
pp. 93-97 ◽  
Author(s):  
L. S. CHUAH ◽  
Z. HASSAN ◽  
F. K. YAM ◽  
H. ABU HASSAN

Porous silicon (PS) samples were prepared by electrochemical anodic etching of n-type (111) silicon wafers in HF solution. The structural, optical, and chemical features of the PS were investigated in terms of different etching durations. The porous samples were investigated by scanning electron microscopy (SEM), photoluminescence (PL), and Raman scattering. SEM images indicated that the pores increased with the etching duration; however, the etching duration has significant effect on the shape of the pores. PL measurements revealed that the porosity-induced PL intensity enhancement was only observed in the porous samples. Raman spectra showed shifting of PS Raman peak to lower frequency relative to non-porous silicon Raman peak.

Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 51
Author(s):  
Michela Relucenti ◽  
Giuseppe Familiari ◽  
Orlando Donfrancesco ◽  
Maurizio Taurino ◽  
Xiaobo Li ◽  
...  

Several imaging methodologies have been used in biofilm studies, contributing to deepening the knowledge on their structure. This review illustrates the most widely used microscopy techniques in biofilm investigations, focusing on traditional and innovative scanning electron microscopy techniques such as scanning electron microscopy (SEM), variable pressure SEM (VP-SEM), environmental SEM (ESEM), and the more recent ambiental SEM (ASEM), ending with the cutting edge Cryo-SEM and focused ion beam SEM (FIB SEM), highlighting the pros and cons of several methods with particular emphasis on conventional SEM and VP-SEM. As each technique has its own advantages and disadvantages, the choice of the most appropriate method must be done carefully, based on the specific aim of the study. The evaluation of the drug effects on biofilm requires imaging methods that show the most detailed ultrastructural features of the biofilm. In this kind of research, the use of scanning electron microscopy with customized protocols such as osmium tetroxide (OsO4), ruthenium red (RR), tannic acid (TA) staining, and ionic liquid (IL) treatment is unrivalled for its image quality, magnification, resolution, minimal sample loss, and actual sample structure preservation. The combined use of innovative SEM protocols and 3-D image analysis software will allow for quantitative data from SEM images to be extracted; in this way, data from images of samples that have undergone different antibiofilm treatments can be compared.


Author(s):  
Debbie G. Jones ◽  
Albert P. Pisano

A novel fabrication process is presented to create ultra thick ferromagnetic structures in silicon. The structures are fabricated by electroforming NiFe into silicon templates patterned with deep reactive ion etching (DRIE). Thin films are deposited into photoresist molds for characterization of an electroplating cell. Results show that electroplated films with a saturation magnetization above 1.6 tesla and compositions of approximately 50/50 NiFe can be obtained through agitation of the electrolyte. Scanning electron microscopy (SEM) images show that NiFe structures embedded in a 500 μm thick silicon wafer are realized and the roughening of the mold sidewalls during the DRIE aids in adhesion of the NiFe to the silicon.


2021 ◽  
Vol 21 (7) ◽  
pp. 3773-3778
Author(s):  
Keon-Young Kim ◽  
Se-Min Jeong ◽  
Chang-Yull Lee

This paper proposes a new mechanism for detecting microscopic damage of structures based on imitating the sensory organs of spiders. Therefore, it is essential to manufacture sensors that can react sensitively to the micro deformations of structures. Numerous cracks were intentionally generated to improve the sensitivity of the proposed sensor, and an increase in the gap of the crack was observed by scanning electron microscopy (SEM) observation. Electrohydrodynamic technology is used to detect deformations in a structure of depositing Ag nano paste on a polyethylene terephtha-late (PET) substrate. Ag nano lines are also observed by SEM images. The sensor is constructed as a grid structure, by forming layers patterned horizontally and vertically. An impact tester is used to verify the mechanism for structural health monitoring using the developed sensor. The resistance changes of the sensors are applied to estimate the structure’s damaged location. The intersections of the lines with varying resistance can be used to accurately detect crack initiation. The proposed mechanism is a powerful methodology for estimating and detecting microscopic deformations and damage to structures.


2020 ◽  
Vol 34 (24) ◽  
pp. 2050249
Author(s):  
L. Yoosefi ◽  
V. Setoodeh

High sensitivity and response ratio of magnetoimpedance (MI) sensors have raised interest for using them in different environments for detection of weak magnetic fields of magnetic elements even though the high dependence of the MI response to the surface condition of the MI sensor has limited its application in some environments. In this study, we investigate the effects originating from the MI measurement in moisturized air. Using scanning electron microscopy (SEM) images, it is observed that the surface of an Fe-based MI sensor has become rough and granular after the presence of moisture on its surface. Results can be useful for developing MI sensors for use in different environmental conditions.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1779 ◽  
Author(s):  
Christoph Naber ◽  
Florian Kleiner ◽  
Franz Becker ◽  
Long Nguyen-Tuan ◽  
Christiane Rößler ◽  
...  

A new method for the nuclear magnetic resonance (NMR) surface relaxivity calibration in hydrated cement samples is proposed. This method relies on a combined analysis of 28-d hydrated tricalcium silicate samples by scanning electron microscopy (SEM) image analysis and 1H-time-domain (TD)-NMR relaxometry. Pore surface and volume data for interhydrate pores are obtained from high resolution SEM images on surfaces obtained by argon broad ion beam sectioning. These data are combined with T2 relaxation times from 1H-TD-NMR to calculate the systems surface relaxivity according to the fast exchange model of relaxation. This new method is compared to an alternative method that employs sequential drying to calibrate the systems surface relaxivity.


1996 ◽  
Vol 457 ◽  
Author(s):  
I. Coulthard ◽  
T. K. Sham

ABSTRACTApart from its well known ability to luminesce very intensely at room temperature in the visible range, porous silicon is also an effective reducing agent. We report the formation of several noble metal (Pd, Ag, Au, Pt) nanostructures by reductive dispersion of metal ions from aqueous solutions onto the surface of porous silicon. The nanophase systems produced by reductive deposition vary with the element deposited and the metallic salt utilized in the process. The resulting nanophase systems were studied using a variety of techniques including: scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and spectroscopie methods using synchrotron radiation.


Biomolecules ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1536
Author(s):  
Ali Daraei ◽  
Marlien Pieters ◽  
Stephen R. Baker ◽  
Zelda de Lange-Loots ◽  
Aleksander Siniarski ◽  
...  

Scanning Electron Microscopy (SEM) is a powerful, high-resolution imaging technique widely used to analyze the structure of fibrin networks. Currently, structural features, such as fiber diameter, length, density, and porosity, are mostly analyzed manually, which is tedious and may introduce user bias. A reliable, automated structural image analysis method would mitigate these drawbacks. We evaluated the performance of DiameterJ (an ImageJ plug-in) for analyzing fibrin fiber diameter by comparing automated DiameterJ outputs with manual diameter measurements in four SEM data sets with different imaging parameters. We also investigated correlations between biophysical fibrin clot properties and diameter, and between clot permeability and DiameterJ-determined clot porosity. Several of the 24 DiameterJ algorithms returned diameter values that highly correlated with and closely matched the values of the manual measurements. However, optimal performance was dependent on the pixel size of the images—best results were obtained for images with a pixel size of 8–10 nm (13–16 pixels/fiber). Larger or smaller pixels resulted in an over- or underestimation of diameter values, respectively. The correlation between clot permeability and DiameterJ-determined clot porosity was modest, likely because it is difficult to establish the correct image depth of field in this analysis. In conclusion, several DiameterJ algorithms (M6, M5, T3) perform well for diameter determination from SEM images, given the appropriate imaging conditions (13–16 pixels/fiber). Determining fibrin clot porosity via DiameterJ is challenging.


Sign in / Sign up

Export Citation Format

Share Document