scholarly journals Effects of region and sex on the mechanical properties of the glenohumeral capsule during uniaxial extension

2010 ◽  
Vol 108 (6) ◽  
pp. 1711-1718 ◽  
Author(s):  
Carrie A. Voycheck ◽  
Eric J. Rainis ◽  
Patrick J. McMahon ◽  
Jeffrey A. Weiss ◽  
Richard E. Debski

Surgical repair of the glenohumeral capsule after dislocation ignores regional boundaries of the capsule and is not sex specific. However, each region of the capsule functions to stabilize the joint in different positions, and differences in joint laxity between men and women have been found. The objectives of this research were to determine the effects of region (axillary pouch and posterior capsule) and sex on the material properties of the glenohumeral capsule. Boundary conditions derived from experiments were used to create finite-element models that applied tensile deformations to tissue samples from the capsule. The material coefficients of a hyperelastic constitutive model were determined via inverse finite-element optimization, which minimized the difference between the experimental and finite-element model-predicted load-elongation curve. These coefficients were then used to create stress-stretch curves representing the material properties of the capsule regions for each sex in response to uniaxial extension. For the axillary pouch, the C1(men: 0.28 ± 0.39 MPa and women: 0.23 ± 0.12 MPa) and C2(men: 8.2 ± 4.1 and women: 7.7 ± 3.0) material coefficients differed between men and women by only 0.05 MPa and 0.5, respectively. Similarly, the posterior capsule coefficients differed by 0.15 MPa (male: 0.49 ± 0.26 MPa and female: 0.34 ± 0.20 MPa) and 0.6 (male: 7.8 ± 2.9 and female: 7.2 ± 3.0), respectively. No differences could be detected in the material coefficients between regions or sexes. As a result, surgeons may not need to consider region- and sex-specific surgical repair techniques. Furthermore, finite-element models of the glenohumeral joint may not need region- or sex-specific material coefficients when using this constitutive model.

Author(s):  
Carrie A. Voycheck ◽  
Patrick J. McMahon ◽  
Richard E. Debski

Glenohumeral dislocation is a significant clinical problem and often results in injury to the anteroinferior (anterior band of the inferior glenohumeral ligament (AB-IGHL) and axillary pouch) glenohumeral capsule. [1] However, clinical exams to diagnose capsular injuries are not reliable [2] and poor patient outcome still exists following repair procedures. [3] Validated finite element models of the glenohumeral capsule may be able to improve diagnostic and repair techniques; however, improving the accuracy of these models requires adequate constitutive models to describe capsule behavior. The collagen fibers in the anteroinferior capsule are randomly oriented [4], thus the material behavior of the glenohumeral capsule has been described using isotropic models. [5,6] A structural model consisting of an isotropic matrix embedded with randomly aligned collagen fibers proved to better predict the complex capsule behavior than an isotropic phenomenological model [7] indicating that structural models may improve the accuracy of finite element models of the glenohumeral joint. Many structural models make the affine assumption (local fiber kinematics follow global tissue deformation) however an approach to account for non-affine fiber kinematics in structural models has been recently developed [8]. Evaluating the affine assumption for the capsule would aid in developing an adequate constitutive model. Therefore, the objective of this work was to assess the affine assumption of fiber kinematics in the anteroinferior glenohumeral capsule by comparing experimentally measured preferred fiber directions to the affine-predicted fiber directions.


1996 ◽  
Vol 118 (4) ◽  
pp. 473-481 ◽  
Author(s):  
Michael R. Bryant ◽  
Peter J. McDonnell

Membrane inflation tests were performed on fresh, intact human corneas using a fiber optic displacement probe to measure the apical displacements. Finite element models of each test were used to identify the material properties for four different constitutive laws commonly used to model corneal refractive surgery. Finite element models of radial keratotomy using the different best-fit constitutive laws were then compared. The results suggest that the nonlinearity in the response of the cornea is material rather than geometric, and that material nonlinearity is important for modeling refractive surgery. It was also found that linear transverse isotropy is incapable of representing the anisotropy that has been experimentally measured by others, and that a hyperelastic law is not suitable for modeling the stiffening response of the cornea.


Author(s):  
William J. Newman ◽  
Richard E. Debski ◽  
Susan M. Moore ◽  
Jeffrey A. Weiss

The shoulder is one of the most complex and often injured joints in the human body. The inferior glenohumeral ligament (IGHL), composed of the anterior band (AB), posterior band (PB) and the axillary pouch, has been shown to be an important contributor to anterior shoulder stability (Turkel, 1981). Injuries to the IGHL of the glenohumeral capsule are especially difficult to diagnose and treat effectively. The objective of this research was to develop a methodology for subject-specific finite element (FE) modeling of the ligamentous structures of the glenohumeral joint, specifically the IGHL, and to determine how changes in material properties affect predicted strains in the IGHL at 60° of external rotation. Using the techniques developed in this research, an improved understanding of the contribution of the IGHL to shoulder stability can be acquired.


2014 ◽  
Vol 1648 ◽  
Author(s):  
Michael Culler ◽  
Keri A. Ledford ◽  
Jason H. Nadler

ABSTRACTRemora fish are capable of fast, reversible and reliable adhesion to a wide variety of both natural and artificial marine hosts through a uniquely evolved dorsal pad. This adhesion is partially attributed to suction, which requires a robust seal between the pad interior and the ambient environment. Understanding the behavior of remora adhesion based on measurable surface parameters and material properties is a critical step when creating artificial, bio-inspired devices. In this work, structural and fluid finite element models (FEM) based on a simplified “unit cell” geometry were developed to predict the behavior of the seal with respect to host/remora surface topology and tissue material properties.


2002 ◽  
Vol 124 (3) ◽  
pp. 734-744 ◽  
Author(s):  
Ihab M. Hanna ◽  
John S. Agapiou ◽  
David A. Stephenson

The HSK toolholder-spindle connection was developed to overcome shortcomings of the 7/24 steep-taper interface, especially at higher speeds. However, the HSK system was standardized quickly, without detailed evaluation based on operational experience. Several issues concerning the reliability, maintainability, and safety of the interface have been raised within the international engineering community. This study was undertaken to analytically investigate factors which influence the performance and limitations of the HSK toolholder system. Finite Element Models were created to analyze the effects of varying toolholder and spindle taper geometry, axial spindle taper length, drawbar/clamping load, spindle speed, applied bending load, and applied torsional load on HSK toolholders. Outputs considered include taper-to-taper contact pressures, taper-to-taper clearances, minimum drawbar forces, interface stiffnesses, and stresses in the toolholder. Static deflections at the end of the holder predicted by the models agreed well with measured values. The results showed that the interface stiffness and load-carrying capability are significantly affected by taper mismatch and dimensional variations, and that stresses in the toolholder near the drive slots can be quite high, leading to potential fatigue issues for smaller toolholders subjected to frequent clamping-unclamping cycles (e.g., in high volume applications). The results can be used to specify minimum toolholder material properties for critical applications, as well as drawbar design and spindle/toolholder gaging guidelines to increase system reliability and maintainability.


2000 ◽  
Author(s):  
Ihab M. Hanna ◽  
John S. Agapiou ◽  
David A. Stephenson

Abstract The HSK toolholder-spindle connection was developed to overcome shortcomings of the 7/24 steep-taper interface, especially at higher speeds. However, the HSK system was standardized quickly, without detailed evaluation based on operational experience. Several issues concerning the reliability, maintainability, and safety of the interface have been raised within the international engineering community. This study was undertaken to analytically investigate factors which influence the performance and limitations of the HSK toolholder system. Finite Element Models were created to analyze the effects of varying toolholder and spindle taper geometry, axial spindle taper length, drawbar/clamping load, spindle speed, applied bending load, and applied torsional load on HSK toolholders. Outputs considered include taper-to-taper contact pressures, taper-to-taper clearances, minimum drawbar forces, interface stiffnesses, and stresses in the toolholder. Static deflections at the end of the holder predicted by the models agreed well with measured values. The results showed that the interface stiffness and load-carrying capability are significantly affected by taper mismatch and dimensional variations, and that stresses in the toolholder near the drive slots can be quite high, leading to potential fatigue issues for smaller toolholders subjected to frequent clamping-unclamping cycles (e.g., in high volume applications). The results can be used to specify minimum toolholder material properties for critical applications, as well as drawbar design and spindle/toolholder gaging guidelines to increase system reliability and maintainability.


Author(s):  
Matthew D. Snyder ◽  
Tama´s R. Liszkai ◽  
Anne Demma

Pressurized water reactor (PWR) internals components can experience material aging and degradation due to irradiation. The purpose of the functionality analysis is to provide a best-estimate evaluation of the reactor internals core barrel assembly for materials degradation to see if the components retain their function. The evaluation uses an irradiated material-specific constitutive model for use in a finite element analysis [1] representing the current state of knowledge for plasticity, creep, stress relaxation, void swelling, and embrittlement. This constitutive model is a function of temperature and fluence. The analysis focuses on finding the integrated effects of material aging combined with steady-state operational characteristics of the reactor internals. In order to evaluate the potential failure mechanisms of the core barrel assembly, finite element models were developed capable of representing the complex interactions between the components. The goal of this specific analysis is to characterize the potential failure modes, spatial and chronological distribution of potential component failures for a representative model of the Babcock & Wilcox-type (B&W) designed plants. Evaluation of the reactor vessel internals for materials aging degradation involves three analytical calculations. Radiation calculations of the core provide essential information on radiation dose and heat rates of the internals. The computational fluid dynamics domain (CFD) allows evaluation of the internals temperatures through conjugate heat transfer (CHT) analysis coupled with coolant flow. Detailed structural analysis of the internals components and bolted connections is the third major physics field involved, which facilitates the development of operating stress fields within the internals. Structural analysis was performed as two parts. First, a global structural model of the core barrel assembly was used to represent the interaction of components of the core barrel assembly during 60 years of operation. The global model does not include detail of the areas of stress concentration within bolted connections. Therefore local models of selected bolts were developed. Results of both the global and local models were used as a basis for evaluating age-related effects. The description of the functionality analysis for the B&W designed RV internals is divided into three papers. Part I was presented in PVP-2008 [2] and included a description of the overall methodology with special attention to CFD-CHT evaluations. Part II, to be presented at PVP 2009 [2] describes global structural finite element models. Part III, presented in this paper, presents a description of local models of bolted connections, results, and conclusions.


Author(s):  
Bai-Qiao Chen ◽  
C. Guedes Soares

The present work aims at better understanding and predicting the thermal and structural responses of aluminum components subjected to welding, contributing to the design and fabrication of aluminum ships such as catamarans, lifesaving boats, tourist ships, and fast ships used in transportation or in military applications. Taken into consideration the moving heat source in metal inert gas (MIG) welding, finite element models of plates made of aluminum alloy are established and validated against published experimental results. Considering the temperature-dependent thermal and mechanical properties of the aluminum alloy, thermo-elasto-plastic finite element analyses are performed to determine the size of the heat-affected zone (HAZ), the temperature histories, the distortions, and the distributions of residual stresses induced by the welding process. The effects of the material properties on the finite element analyses are discussed, and a simplified model is proposed to represent the material properties based on their values at room temperature.


Author(s):  
Kelvin Luu ◽  
Carrie A. Voycheck ◽  
Patrick J. McMahon ◽  
Richard E. Debski

The glenohumeral joint is frequently dislocated causing injury to the glenohumeral capsule (axillary pouch (AP), anterior band of the inferior glenohumeral ligament (AB-IGHL), posterior band of the inferior glenohumeral ligament (PB-IGHL), posterior (Post), and anterosuperior region (AS)). [1, 2] The capsule is a passive stabilizer to the glenohumeral joint and primarily functions to resist dislocation during extreme ranges of motion. [3] When unloaded, the capsule consists of randomly oriented collagen fibers, which play a pertinent role in its function to resist loading in multiple directions. [4] The location of failure in only the axillary pouch has been shown to correspond with the highest degree of collagen fiber orientation and maximum principle strain just prior to failure. [4, 5] However, several discrepancies were found when comparing the collagen fiber alignment between the AB-IGHL, AP, and PB-IGHL. [3,6,7] Therefore, the objective was to determine the collagen fiber alignment and maximum principal strain in five regions of the capsule during uniaxial extension to failure and to determine if these parameters could predict the location of tissue failure. Since the capsule functions as a continuous sheet, we hypothesized that maximum principal strain and peak collagen fiber alignment would correspond with the location of tissue failure in all regions of the glenohumeral capsule.


2015 ◽  
Vol 2015 ◽  
pp. 1-9 ◽  
Author(s):  
Yulong Ge ◽  
Xiaoxing Li ◽  
Lihui Lang

Tubular material parameters are required for both part manufactory process planning and finite element simulations. The bulging test is one of the most credible ways to detect the property parameters for tubular material. The inverse approach provides more effective access to the accurate material evaluation than with direct identifications. In this paper, a newly designed set of bulging test tools is introduced. An inverse procedure is adopted to determine the tubular material properties in Krupkowski-Swift constitutive model of material deformation using a hybrid algorithm that combines the differential evolution and Levenberg-Marquardt algorithms. The constitutive model’s parameters obtained from the conventional and inverse methods are compared, and this comparison shows that the inverse approach is able to offer more information with higher reliability and can simplify the test equipment.


Sign in / Sign up

Export Citation Format

Share Document