scholarly journals A New Approach to the RP-HPLC Method for Simultaneous Estimation of Atorvastatin Calcium and Fenofibrate in Pharmaceutical Dosage Forms

2012 ◽  
Vol 9 (3) ◽  
pp. 1223-1229 ◽  
Author(s):  
S. D. Bhinge ◽  
S. M. Malipatil ◽  
A. Jondhale ◽  
R. Hirave ◽  
A. S. Savali

The present manuscript describes the development and validation of an isocratic reverse phase high-performance liquid chromatographic (RP-HPLC) method for the estimation of Atorvastatin calcium and Fenofibrate in raw material and tablet. Atorvastatin Calcium, Fenofibrate and Diclofenac (internal standard) were well separated using a reversed phase column and mobile phase consisting of acetonitrile:KH2PO4(50 mM) (72:28v/v) (pH 4.1). The mobile phase was pumped at 1.0 mL/min flow rate and atorvastatin calcium and fenofibrate were detected by UV-Vis detection at 260 nm. The retention time for atorvastatin calcium, Internal Standard and fenofibrate were 4.34, 5.35 and 12.05 min, respectively. The LOD and LOQ was found to be 1.95 and 4.80 µg/mL for atorvastatin calcium whereas for fenofibrate it was found to be 1.73 and 3.98 µg/mL in mobile phase. The developed method was validated by applying parameters as precision, accuracy, selectivity, reproducibility and system suitability tests.

INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 59-68
Author(s):  
H Mahajan ◽  
S Savale ◽  
P Nerkar ◽  

The present study was aimed at developing a Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) method for simultaneous determination of curcumin (CRM) and gefitinib (GFT) in bulk, plasma and brain homogenate. hydrochlorothiazide was used as an internal standard (IS). A new simple, rapid, selective, precise and accurate RP-HPLC method has been developed. The separation was achieved by using C-18 column (Qualisil BDS C18, 250 mm x 4.6 mm I.D.) coupled with a guard column of silica, mobile phase consisted of acetonitrile: water with 0.1% formic acid (30:70 v/v). The flow rate was 0.2 ml/min and the drug was detected using PDA detector at the wavelength of 242 nm. The experimental conditions, including the diluting solvent, mobile phase composition, column saturation and flow rate, were optimised to provide high-resolution and reproducible peaks. The method was developed and tested for linearity range of 10-60 μg/mL for bulk analysis and 200-800 ng/mL for plasma and brain homogenate. The developed method was validated as per ICH guidelines, in terms of linearity, application of the proposed method to bulk sample, recovery, precision, repeatability, ruggedness, sensitivity (LOD and LOQ) and robustness and stability study (short and long-term stabilities, freeze/thaw stability, post-preparative). The low value of % RSD showed that the method was precise within the acceptance limit of 2%. The developed method was successfully applied for the analysis of the drug in bulk as well as various marketed formulation and drug in plasma and brain distribution studies.


2013 ◽  
Vol 16 (1) ◽  
pp. 69-75 ◽  
Author(s):  
Khohinur Hossain ◽  
Asma Rahman ◽  
Md Zakir Sultan ◽  
Farhana Islam ◽  
Md Akteruzzaman ◽  
...  

A simple, fast and economic reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed and validated for simultaneous and quantitative analyses of pioglitazone HCl and glimepiride in pharmaceutical dosage forms. The method was developed using the mobile phase comprising of potassium dihydrogen phosphate buffer (KH2PO4) at pH 3.4 and acetonitrile in the ratio of 40:60 (v/v) over C-18 bonded silica column (250 x 4.6 mm, 5 um, Phenomenex Inc.) at ambient temperature. The flow rate was at 0.8 min/min and the eluent was monitored by UV detection at 235 nm. The recoveries were found to be >97% for pioglitazone and >99% for glimepiride, demonstrative of accuracy of the protocol. Inter-day and intra-day precision of the new method were less than the maximum allowable limit (RSD% ? 2.0) according to ICH, USP and FDA guidelines. The method showed linear response with correlation coefficient (r2) values of 0.9991 for pioglitazone and 0.9999 for glimepiride. Therefore, the method was found to be accurate, reproducible, sensitive and less time consuming and can be successfully applied for the assay of pioglitazone and glimepiride in combined formulations. DOI: http://dx.doi.org/10.3329/bpj.v16i1.14497 Bangladesh Pharmaceutical Journal 16(1): 69-75, 2013


2019 ◽  
Vol 11 (1) ◽  
pp. 94
Author(s):  
Swati Sahani ◽  
Vandana Jain

Objective: The objective of this study was to develop and validate a novel, simple, rapid, precise and accurate reversed-phase high performance liquid chromatographic (RP-HPLC) method for simultaneous quantitative estimation of berberine, quercetin, and piperine in Ayurvedic formulation.Methods: The chromatographic separation was achieved using a stationary phase C18 shim-pack (150 mm x 4.6 mm, 5µ) column and mobile phase consisted of acetonitrile: 0.04 M potassium dihydrogen phosphate buffer (pH 3.0 adjusted using orthophosphoric acid) in a ratio of 65:35 v/v, with a flow rate of 1 ml/min and UV detection at 255 nm.Results: The retention time of berberine, quercetin, and piperine were found to be 2.7, 3.0 and 6.3 min respectively. Linearity for berberine, quercetin, and piperine were found in the range of 12-28 µg/ml. All calibration curve showed good linear correlation coefficients (r2˃ 0.999) within the tested ranges. Mean percent recoveries for berberine, quercetin, and piperine were found to be within the acceptance limits (98-120%). The percent relative standard deviation (% RSD) for precision was found to be less than 2% which indicates method is precise.Conclusion: The developed method is novel, simple, precise, accurate and can be used for quantitative analysis and quality control of the raw material as well as other commercial formulations containing these three markers.


1970 ◽  
Vol 3 (1) ◽  
pp. 49-53 ◽  
Author(s):  
Gaurav Patel ◽  
Sanjay Patel ◽  
Dhamesh Prajapiti ◽  
Rajendra Mehta

A reverse phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous estimation of Amlodipine Besylate and Hydrochlorothiazide in combine dosage form. Amlodipine Besylate (AML) is a long acting calcium channel blocker and in the treatment of CVS disorder. Hydrochlorothiazide (HCT) is a diuretic and antihypertensive. The mobile phase used was a combination of Water: Methanol (70:30). The detection of the combined dosage form was carried out at 245nm and a flow rate employd was 0.5ml/min. The retention time for Amlodipine Besylate and Hydrochlorothiazide was found to be 6.95 and 2.65 min respectively. Linearity was obtained in the concentration range of 6 to 18μg/ml of Amlodipine Besylate and 6 to 18μg/ml of Hydrochlorothiazide with a correlation coefficient of 0.997 and 0.9974. Detector consists of photodiode array detector; the reversed phase column used was RP-C18 (5 μm size, 250mm, 4.6mm i.d.) at ambient temperature. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method is precise, selective and rapid for simultaneous estimation of Amlodipine Besylate and Hydrochlorothiazide in routine analysis. Key Words: Simultaneous Estimation; Amlodipine Besylate; Hydrochlorothiazide; HPLC. DOI: 10.3329/sjps.v3i1.6798S. J. Pharm. Sci. 3(1): 49-53


Author(s):  
D. Chinababu

Aim: The objective of the study was simplest, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Velpatasvir (VEL) and Sofosbuvir (SOF) in the bulk and its tablet dosage form. Study Design: The Quantitative and Qualitative estimation and designed forced degradation study of Velpatasvir & Sofosbuvir by RP-HPLC. Place and Duration of Study: The study was carried at Santhiram College of Pharmacy and time taken 4 months. Method: The method was attained by used Waters( 5µm, C18 250 x 4.6 mm) column with mobile phase consists of  0.5 mM disodium hydrogen phosphate buffer pH adjusted to 6.5, with Orthophosphoric acid and Methanol in the ratio of 78:22 v/v, a flow rate of 1.0 mL/min and ultraviolet detection at 285 nm. Results: The method was validated as per ICH guidelines with different parameters, the mean retention times of VEL and SOF were found to be 2.8 & 4.7 min respectively. The resolution between VEL and SOF was found to be 10.66. The Correlation coefficients for calibration curves within the detection range of 32.5 - 97.5 and 125 - 375 µg/mL were 0.999 for VEL and SOF respectively. The LOD and LOQ for VEL and SOF were found to be 0.0068-0.029 µg/mL and 0.104-0.342 µg/mL respectively. Conclusion: The results were indicated that the developed method was used for the routine analysis of VEL & SOF combined form in bulk and its commercial formulation. To the best of our knowledge, there was no method of RP-HPLC for the determination of VEL alone or in combination with SOF molecule.


Author(s):  
Manasi Kulkarni B ◽  
Anagha Joshi M

Objective: The objective is to study the development of a simple, rapid, specific, precise, and accurate reversed-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of serratiopeptidase (SER) and diclofenac (DC) sodium in bulk and tablet formulation.Methods: RP-HPLC method was developed for the simultaneous estimation of SER and DC sodium in tablet formulation. The separation was achieved by Kromasil C18 column (250 mm × 4.6 mm, 5 μm particle size) with phosphate buffer pH-7 and o-phosphoric acid:methanol:acetonitrile (5:4:1% v/v/v). Flow rate was maintained at 1 mL/min and UV detection was carried at 270 nm.Result: For RP-HPLC method, the retention time for SER and DC sodium was found to be 3.3833 min and 8.1667 min, respectively. The method was validated for accuracy, precision, and specificity. Linearity for SER and DC sodium was in the range of 5–50 μg/ml.Conclusion: The developed RP-HPLC method is simple, accurate, rapid, sensitive, precise, and economic. Hence, this method can be employed successfully for the estimation of SER and DC sodium in both bulk and tablet dosage forms.


Author(s):  
Grishma H Patel ◽  
Shreya D Adeshra ◽  
Dhananjay B Meshram

A Novel, selective, accurate and rapid Reversed Phase High Performance Liquid Chromatographic (RPHPLC) method for the analysis of Efonidipine Hydrochloride Ethanolate and Telmisartan in binary mixture has been developed and validated. The chromatographic system consisted of a Phenomenex Kinetex ® 5µ C18 Size: 150 * 4.6mm column and the separation was achieved by using ambient temperature with a mobile phase containing mobile Phase Acetonitrile:25mM Phosphate Buffer pH 4.9 (45:55). The samples were monitored at 253 nm for detection at a flow rate of 1.0 mL/min and the retention time was about 7.77 and 4.10 mins for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The calibration curve was linear over the concentration range 5-30 and 10-60 ?g/mL for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The proposed method is accurate in the range of 99.75% - 100.10% recovery and precise (%RSD of intraday variation and % RSD of inter day variation were found to be within the acceptance criteria). Therefore, this method can be used as a more convenient and efficient option for the analysis of Efonidipine Hydrochloride Ehanolate and Telmisartan in Quality control laboratory.


Author(s):  
Manasi Kulkarni B ◽  
Anagha Joshi M

Objective: The objective is to study the development of a simple, rapid, specific, precise, and accurate reversed-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of serratiopeptidase (SER) and diclofenac (DC) sodium in bulk and tablet formulation.Methods: RP-HPLC method was developed for the simultaneous estimation of SER and DC sodium in tablet formulation. The separation was achieved by Kromasil C18 column (250 mm × 4.6 mm, 5 μm particle size) with phosphate buffer pH-7 and o-phosphoric acid:methanol:acetonitrile (5:4:1% v/v/v). Flow rate was maintained at 1 mL/min and UV detection was carried at 270 nm.Result: For RP-HPLC method, the retention time for SER and DC sodium was found to be 3.3833 min and 8.1667 min, respectively. The method was validated for accuracy, precision, and specificity. Linearity for SER and DC sodium was in the range of 5–50 μg/ml.Conclusion: The developed RP-HPLC method is simple, accurate, rapid, sensitive, precise, and economic. Hence, this method can be employed successfully for the estimation of SER and DC sodium in both bulk and tablet dosage forms.


2010 ◽  
Vol 93 (4) ◽  
pp. 1059-1068 ◽  
Author(s):  
Predrag Lj Džodić ◽  
Ljiljana J ivanovi ◽  
Ana D Proti ◽  
Mira L Zeevi ◽  
Biljana M Joci

Abstract An accurate and precise RP-HPLC method was developed and validated for the determination of carbamazepine and its impurities iminostilbene and iminodibenzyl in a tablet formulation with fluphenazine as an internal standard. Buffermethanol (50 + 50, v/v) was used as the mobile phase. During validation, specificity, linearity, precision, accuracy, LOD, LOQ, and robustness of the method were tested. The method was proven to be specific against placebo interference. Linearity was evaluated over the concentration range of 100500, 0.050.25, and 0.10.5 g/mL, and the r values were 0.9994, 0.9997, and 0.9979 for carbamazepine, iminostilbene, and iminodibenzyl, respectively. Intraday precision of the method was good, and RSD was below 2 for all analytes. The accuracy of the method ranged from 100.69 to 102.10, 99.76 to 102.66, and 99.26 to 100.08 for carbamazepine, iminostilbene, and iminodibenzyl, respectively. LOD was 0.0125, 0.025, and 0.05 g/mL and LOQ was 0.05, 0.05, and 0.1 g/mL for carbamazepine, iminostilbene, and iminodibenzyl, respectively. Robustness of the method was proven by using a chemometric approach. The method was successfully applied to the analysis of commercially available carbamazepine tablets and showed good repeatability, with RSD below 2.


2019 ◽  
Vol 9 (01) ◽  
pp. 83-88
Author(s):  
Pinkal Patel ◽  
Nalini Patel ◽  
Kinjal Parmar

A simple, selective and rapid reversed phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed and validated for the simultaneous analysis Gatifloxacin and flurbiprofen sodium in eye drops. The separation was carried out using a mobile phase consisting ACN: Buffer (pH 3.5) in the ratio of 55:45 v/v. The column used was Phenomenex luna ODS C18 (250mm X 4.6 mm i.d., 5 μm particle size) with flow rate of 1 ml / min using UV detection at 268 nm. The described method was linear over a concentration range of 2-12 μg/ml for both of Gatifloxacin and flurbiprofen sodium. The retention times of Gatifloxacin and flurbiprofen sodium were found to be 3.710 min. and 6.797 min respectively. Method was validated statistically and recovery studies were carried out. The proposed method has been applied successfully to the analysis of cited drugs either in pure form or in pharmaceutical formulations with good accuracy and precision. The method here in described can be employed for quality control and routine analysis of drugs in pharmaceutical formulations.