scholarly journals Variables Affecting the Accuracy of Implant Master Casts: An In Vitro Pilot Study

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Matthias Karl ◽  
Victor Palarie

Impression and master cast accuracy have been identified as being the major determinants of superstructure fit in implant-supported restorations. The goal of this in vitro investigation was to determine the effects of different transfer components, impression materials, disinfection, storage time, and stone type on master cast accuracy. Following impression making from a reference model with two internal-hex bone-level implants and master cast fabrication (eight experimental groups; n = 5), a bar-type measurement device equipped with a strain gauge was fixed on all master casts while strain development was recorded. Statistical analysis was performed applying ANOVA and paired t-tests with the level of significance set at α = 0.05. The transfer components with plastic sleeves caused maximum misfit strain which was significantly greater as compared to click (P = 0.02) and open tray transfer components (P = 0.00). No significant effect on master cast accuracy was recorded for the parameters impression material, impression disinfection, and storage of impressions or casts. Lower strain development was observed in casts poured in type 3 stone as compared to casts poured in type 4 stone (P = 0.01). For the bone-level implant system considered here, the great levels of accuracy could be achieved using pick-up impressions with either click or open tray impression components.

2020 ◽  
Vol 9 (5) ◽  
pp. 1436 ◽  
Author(s):  
Tim Joda ◽  
Lea Matthisson ◽  
Nicola U. Zitzmann

The aim of this in vitro study was to analyze the impact of model aging on the accuracy of 3D-printed dental models. A maxillary full-arch reference model with prepared teeth for a three-unit fixed dental prosthesis was scanned ten times with an intraoral scanner (3Shape TRIOS Pod) and ten models were 3D printed (Straumann P-Series). All models were stored under constant conditions and digitized with a desktop scanner after 1 day; 1 week; and 2, 3, and 4 weeks. For accuracy, a best-fit algorithm was used to analyze the deviations of the abutment teeth (GFaI e.V Final Surface®). Wilcoxon Rank Sum Tests were used for comparisons with the level of significance set at α = 0.05. Deviation analysis of the tested models showed homogenous intragroup distance calculations at each timepoint. The most accurate result was for 1 day of aging (3.3 ± 1.3 µm). A continuous decrease in accuracy was observed with each aging stage from day 1 to week 4. A time-dependent difference was statistically significant after 3 weeks (p = 0.0008) and 4 weeks (p < 0.0001). Based on these findings, dental models should not be used longer than 3 to 4 weeks after 3D printing for the fabrication of definitive prosthetic reconstructions.


2014 ◽  
Vol 40 (2) ◽  
pp. 137-145 ◽  
Author(s):  
Malesh Pujari ◽  
Pooja Garg ◽  
D. R. Prithviraj

Movement of impression copings inside the impression material using a direct (open tray) impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the cast. Consequently, the prosthesis may require corrective procedures. This in vitro study evaluated the accuracy of 3 different impression techniques using polyether and vinyl polysiloxane (VPS) impression material to obtain a precise cast for multiple internal connection implants. A reference acrylic resin model with 4 internal connection implants was fabricated. Impressions of the reference model were made using 3 different techniques and 2 different impression materials. The study consisted of 24 specimens divided into 6 groups of 4 each. Impressions were poured with ADA type IV stone (Kalrock, Kalabhai Karson Pvt Ltd, Mumbai, India). All casts were evaluated for the positional accuracy (mm) of the implant replica heads using a profile projector. These measurements were compared to the measurements calculated on the reference resin model, which served as a control. Data were analyzed with 2-way analysis of variance (ANOVA) followed by Bonferroni multiple comparison procedures to evaluate group means. The results revealed significant difference for anterior implant distance between the 2 impression materials (P &lt; .01) and also among the 3 different techniques (P &lt; .05). The lowest mean variation was found with the polyether impression material and the splinted technique. For posterior implants, the results suggested no significant difference between the 2 impression materials (P ≥ .05). Although results were not statistically significant, the polyether impression material showed the lowest mean variation as compared to the VPS impression material. However, there was a significant difference among the 3 different techniques (P &lt; .05). Among the 3 different techniques, the lowest mean variation between 2 posterior implants was found in the splinted technique. Casts obtained from impression techniques using square impression copings splinted together with autopolymerizing acrylic resin prior to the impression procedure were more accurate than casts obtained from impressions with nonmodified implant impression copings and with airborne particle–abraded, adhesive-coated copings. Casts obtained from polyether impression material were more accurate than casts obtained from vinyl polysiloxane impression material.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Sonam Gupta ◽  
Aparna Ichalangod Narayan ◽  
Dhanasekar Balakrishnan

Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique.Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n=5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA.Results. Statistically significant difference (p<0.05) was found between the two impression materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p>0.05) was observed between varied stock and custom trays.Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials.


Author(s):  
Xuetao Zhang ◽  
Jian Mao ◽  
Yufeng Zhou ◽  
Fangqiu Ji ◽  
Xianshuai Chen

Alveolar bone atrophy can directly cause a decrease in bone level. The effect of this process on the service life of dental implants is unknown. The aim of this study was to determine the failure forms of the two-piece dental implants in the descending process of alveolar bone level, and the specific states of the components during the failure process. The CAD software SolidWorks was used to establish the model of alveolar bone and dental implants in this article. The finite element analysis was used to analyze the statics of the dental implants in the host oral model. The finite element analysis results showed that the stress concentration point of the implant and abutment in the implant system has changed greatly during the descending process of alveolar bone level, and indirectly increased the fatigue life of the same fatigue risk point. At the same time, the dental implants were tested in vitro in the descending process of alveolar bone level. Then, the fracture of the implant system was scanned by scanning electron microscope. The fatigue test results proved the finite element analysis hypothesis the central screw first fractured under fatigue and then caused an overload break of the implant and abutment.


2021 ◽  
Vol 11 (13) ◽  
pp. 6186
Author(s):  
Saverio Cosola ◽  
Paolo Toti ◽  
Enrico Babetto ◽  
Ugo Covani ◽  
Miguel Peñarrocha-Diago ◽  
...  

Background: The present in vitro study aimed to investigate the fatigue performance of different dental fixtures in two different emergence profiles. Biological failures are frequently reported because the problem canonly be solved by replacing a failing implant with a new one. Clinicians addressed minor mechanical failures, such as bending, loosening or the fracture of screws, abutment, or the entire prosthesis, by simply replacing or fixing them. Methods: Transmucosal and submerged bone-level dental implants underwent fatigue strength tests (statical and dynamical performance) by a standardized test: UNI EN ISO 14801:2016. Two types of emergence profiles (Premium sub-crestal straight implant with a cylindrical-shaped coronal emergence or Prama one-piece cylindrical-shape implant with transmucosal convergent neck and hyperbolic geometry) were tested, and dynamic fatigue were run to failure. Data was analyzed by a suitable statistical tool. Results: The Wöhler curve of 0.38 cm Premium group c2, appeared to be significantly different from that of the 0.38 cm Prama group c3 (nonparametric one-way ANOVA χ2 = 6; degree of freedom = 1; probability = 0.0043) but not from that of the 0.33 cm Premium group c1 (nonparametric one-way ANOVA χ2 = 0.62; degree of freedom = 1; probability = 0.4328). Fatigue performance of configuration 2 was one and a half times better than that of configuration 3. Group c3 had a better ultimate failure load (421.6 ± 12.5 N) than the other two settings i.e., c1 (324.5 ± 5.5 N) and c2 (396.3 ± 5.6) reaching almost a nonsignificant level. Conclusions: It was observed that a transmucosal implant design could provide the highest resistance to static fracture. On the other hand, an equicrestal implant design could increase dynamic endurance.


2008 ◽  
Vol 35 (S 01) ◽  
Author(s):  
H Leske ◽  
A Baiker ◽  
C Schichor ◽  
J.C Tonn ◽  
R Goldbrunner ◽  
...  

2010 ◽  
Vol 51 (8) ◽  
pp. 4151 ◽  
Author(s):  
Henri Sueke ◽  
Stephen B. Kaye ◽  
Timothy Neal ◽  
Amanda Hall ◽  
Stephen Tuft ◽  
...  

2021 ◽  
Vol 19 ◽  
pp. 228080002110068
Author(s):  
Hsien-Te Chen ◽  
Hsin-I Lin ◽  
Chi-Jen Chung ◽  
Chih-Hsin Tang ◽  
Ju-Liang He

Here, we present a bone implant system of phase-oriented titanium dioxide (TiO2) fabricated by the micro-arc oxidation method (MAO) on β-Ti to facilitate improved osseointegration. This (101) rutile-phase-dominant MAO TiO2 (R-TiO2) is biocompatible due to its high surface roughness, bone-mimetic structure, and preferential crystalline orientation. Furthermore, (101) R-TiO2 possesses active and abundant hydroxyl groups that play a significant role in enhancing hydroxyapatite formation and cell adhesion and promote cell activity leading to osseointegration. The implants had been elicited their favorable cellular behavior in vitro in the previous publications; in addition, they exhibit excellent shear strength and promote bone–implant contact, osteogenesis, and tissue formation in vivo. Hence, it can be concluded that this MAO R-TiO2 bone implant system provides a favorable active surface for efficient osseointegration and is suitable for clinical applications.