scholarly journals Validation of a Serum Analysis Method to Analyze Antihistamines by Capillary Electrophoresis

2014 ◽  
Vol 2014 ◽  
pp. 1-6
Author(s):  
J. Peris-Vicente ◽  
S. Carda-Broch ◽  
J. Esteve-Romero

The validation of an electrophoresis-based analytical method to quantify 17 antihistamines in pharmaceutical formulations and serum is described. Then, whether the methodology provides true values with low uncertainty and is able to detect the concentration range level of analyte usually found in the matrix was evaluated. The analytical method was validated following the recommendations of an official guide to provide more reliability to the results. The ICH Harmonized Tripartite Guideline was selected because it was especially developed for analysis of drugs. The guide and the following required validation parameters, selectivity, calibration range, linearity, limit of detection, limit of quantification, inter- and intraday accuracy and precision, and robustness, were described. The method was inexpensive, fast, simple, environmentally friendly, and useful for routine analysis. The methodology was successfully validated and applied to commercial pharmaceutical formulations and spiked blank serum samples.

Author(s):  
DAVID ALEXANDER ◽  
Abdul Rohman

Objective: The aim of this research was to validate inductively coupled plasma-atomic emission spectroscopy (ICP-AES) for quantitative analysis of cadmium (Cd), chromium (Cr), cuprum (Cu), mangan (Mn) and nickel (Ni) in milk products. Methods: The heavy metals in milk were determined using ICP-AES at optimized wavelength. The method was validated by assessing several validation parameters which included linearity and range, accuracy, precision and sensitivity expressed by the limit of detection and limit of quantification. The validated method was then used for the analysis of milks commercially available. Results: ICP-AES for determination of Cd, Cr, Cu, Mn, and Ni was linear over a certain concentration range with a coefficient correlation value of>0.997. The limit of quantification values of Cd, Cr, Cu, Mn, and Ni were 0.0047; 0.0050; 0.0066; 0.0061; and 0.0169 µg/ml, respectively. The precision of analytical method exhibited relative standard deviation (RSD) values of 3.18%; 4.17%; 3.05%; 2.93%; and 4.47% during repeatability test and 5.28%; 5.06%; 3.67%; 3.67%; and 11.17% during intermediate precision of Cd, Cr, Cu, Mn, and Ni respectively. The recoveries of these metals assessed using standard addition method were 92.25; 90.88; 102.87; 94.50; and 86.85%, respectively. Conclusion: ICP-AES offered a reliable and fast method for the determination of heavy metals in milk products. The developed method could be proposed as an official method for determination of heavy metals in milk products.


2019 ◽  
Vol 31 (1) ◽  
pp. 32-39
Author(s):  
Suman Shrivastava ◽  
Pooja Deshpande ◽  
S. J. Daharwal

Development of a method is crucial for discovery, development, and analysis of medicines in the pharmaceutical formulation. Method validation could also be thought to be one in all the foremost well-known areas in analytical chemistry as is reproduced within the substantial variety of articles submitted and presented in peer review journals every year. Validation of an analytical procedure is to demonstrate that it's appropriate for its intended purpose. Results from method validation are often wont to decide the quality, reliability and consistency of analytical results. Analytical methods need to be validated or revalidated. This review describes general approach towards validation process and validation parameters to be considered during validation of an analytical method. It also refers to various regulatory requirements like WHO, USFDA, EMEA, ICH, ISO/IEC. The parameters described here are according to ICH guidelines which include accuracy, precision, specificity, limit of detection, limit of quantification, linearity range and robustness.


Author(s):  
MUCHTARIDI MUCHTARIDI ◽  
Kurnia Megawati ◽  
Febrina Amelia Saputri ◽  
Mulyana Mulyana

Objective: The purpose of this study was to obtain a valid analytical method for determining the level of 2,5-hexanedione in the urine of oil industry workers. Methods: Gas Chromatography (GC) was employed to analyze 2,5-hexanedione in the urine. The analysis was done using HP-5 (Crosslinked methyl siloxane) capillary columns 30 m x 0.320 mm long, film thickness 0.25 μm. The temperature of the detector temperature was 300 °C, and the injector temperature was 250 °C. The helium gas flow rate was 2 ml/min. The detector was Flame Ionization Detection (FID). Parameters of system suitability test and validation were obtained. Results: This study results that the method of analysis 2,5-hexanedione in urine by Gas Chromatography (GC) confirm the requirements of the validation method with a linearity was 0.99963, accuracy was in the range of 99.16% to 114.13%, the precision with % coefficient of variation was 1.65% to 5.16%, % coefficient variation of specificity was 0.027%, limit of detection was 0.054 μg/ml and limit of quantification was 0.18 μg/ml. Conclusion: The proposed GC method meets the acceptance criteria of validation parameters and can be applied for routine analysis.


2014 ◽  
Vol 50 (4) ◽  
pp. 793-797 ◽  
Author(s):  
Vanita Somasekhar

A reverse phase HPLC method is described for the determination of 6-mercaptopurine in bulk and tablets. Chromatography was carried on a C18 column using a mixture of acetonitrile and 0.05 mol/L sodium acetate buffer (10:90 v/v) as the mobile phase at a flow rate of 1 mL/min-1 with detection at 324 nm. The retention time of the drug was 3.25 min. The detector response was linear in the concentration of 0.01-5 μg/mL. The limit of detection and limit of quantification were 17 and 52 ng/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of mercaptopurine in bulk and tablets.


2020 ◽  
pp. 1-8
Author(s):  
M. Pernica ◽  
J. Martiník ◽  
R. Boško ◽  
V. Zušťáková ◽  
K. Benešová ◽  
...  

The present study describes using molecularly imprinted polymer (MIP) technology for determination of patulin (PAT) and 5-hydroxymethylfurfural (5-HMF) in beverages by ultra-high performance liquid chromatography coupled to photodiode array (UPLC-PDA). PAT (4-hydroxy-4H-furo[3,2-c]pyran-2(6H)-one) is a mycotoxin produced by Penicillium fungi and Penicillium expansum is probably the most commonly encountered species that infects apples during their growth, harvest, storage or processing. The occurrence of PAT as a natural contaminant of apples is a worldwide problem. 5-HMF (also known as 5-(hydroxymethyl) furan-2-carbaldehyde), is formed in the Maillard reaction as well as during caramelisation. It is a good storage time-temperature marker and flavour indicator, especially in beverages such as wine, beer, but also cider and apple juice which may contain PAT. PAT and 5-HMF were separated within 2 min using a Luna Omega C18 column and the PDA detector wavelength was set to 276 nm. The validation parameters of the analytical method such as linearity, limit of detection, limit of quantification, accuracy and precision were tested. The calibration curves were linear at least in the range 50-1000 ng/ml with a good linearity (R2>0.999) for both analytes, the limit of detection and the limit of quantification for PAT and 5-HMF were in the range 4.9-6.6 and 16.1-21.8 μg/l, respectively. The recoveries of the selected analyte were in the range 61.9-109.0% with a precision of <8.2% (relative standard deviation (RSD)) for PAT and in the range 50.8-98.0% with a precision of <10.0% (RSD) for 5-HMF. The validated procedure was successfully applied for the analysis of PAT and 5-HMF in beverages from retail shops.


2018 ◽  
Vol 9 (1) ◽  
pp. 7-12 ◽  
Author(s):  
Maha Osama El-Kayal ◽  
Maha Nasr Sayed ◽  
Nahed Dawood Mortada ◽  
Seham Elkheshen

(-)-Epigallocatechin gallate (EGCG) is a catechin found in green tea that has potential health benefits, such as anti-oxidant, anti-carcinogenic and anti-inflammatory effects. A rapid and sensitive Ultra-Performance Liquid Chromatographic (UPLC) method was developed and validated for the estimation of (-)-epigallocatechin-3-gallate in lipid-based formulation. The UPLC method was conducted on C18 analytical column (50 mm × 2.1 mm, 1.8 μm particle size). The mobile phase consisted of a mixture of acetic acid (1%, v:v; pH = 3), acetonitrile and water at volume ratio of 13:15:72 delivered at a flow rate of 0.5 mL/min. The diode array detector (DAD) acquisition wavelength was set at wavelengths 210 and 280 nm. Caffeine was used as internal standard. The tested validation parameters, i.e., selectivity, linearity, accuracy, precision, and sensitivity (Limit of detection and limit of quantification) were determined at both wavelengths. Results revealed that caffeine and EGCG peaks were eluted at retention times of 0.55 and 0.85 minutes, respectively. The calibration curve was linear over the concentration range of 10-60 μg/mL, with coefficients of determination (r2) of 0.9993 and 0.9998 nm at 210 and 280 nm, respectively. All the validation parameters were found within the acceptable range. The proposed method was successfully applied for the quantitation of EGCG in lipid-based formulation and statistical analysis with a reported method showed no significant difference at p < 0.05. Therefore, the proposed analytical method for EGCG can be considered as a rapid, selective and accurate analytical method that can be used for the quantitative analysis of EGCG.


Author(s):  
Valmir Gomes De Souza ◽  
FabrÍcio Havy Dantas De Andrade ◽  
Fabio Santos De Souza ◽  
Rui Oliveira Macedo

Objective: The Anadenanthera colubrina (Vell.) Brennan var. cebil is a medicinal plant that has been used for the treatment of many diseases in the northeastern region of Brazil. This plant contains secondary metabolites such as quercetin, a flavonoid that is known by its antioxidant and anti-inflammatory effects. The aim of this work is to propose the validation of an analytical method using high-performance liquid chromatography with diode array detector (HPLC-DAD) for the quantification of quercetin and standardization of the hydroalcoholic extract (HAE) of A. colubrina.Methods: The A. colubrina extracts were prepared by the maceration process with powdered leaves at 20% weight: volume (w/v) and a hydroalcoholic solution at 50% volume: volume (v/v) for 120 h at room temperature. After pretreatment of the hydroalcoholic extract, the quercetin marker was used for quantification and proceeded to the evaluation of validation parameters for the method using HPLC-DAD.Results: The analytical method proved to be specific. Linear over the range 1.4–26.6 µg/ml, regression analysis showed a good correlation coefficient (R2= 0.999); the limit of detection (LOD) and the limit of quantification (LOQ) were 0.27 and 0.81 μg/ml respectively. The relative standard deviation (RSD) did not exceed 2.5% for precision. The proposed method was validated with an average recovery of 92.5–97.5%.Conclusion: The method was validated using HPLC-DAD, allowing the quantification of quercetin in the standardisation process of extracts and quality control of the herbal drug containing A. colubrina Phyto complex.


Author(s):  
Nesma M Fahmy ◽  
Adel M Michael

Abstract Background Modern built-in spectrophotometer software supporting mathematical processes provided a solution for increasing selectivity for multicomponent mixtures. Objective Simultaneous spectrophotometric determination of the three naturally occurring antioxidants—rutin(RUT), hesperidin(HES), and ascorbic acid(ASC)—in bulk forms and combined pharmaceutical formulation. Method This was achieved by factorized zero order method (FZM), factorized derivative method (FD1M), and factorized derivative ratio method (FDRM), coupled with spectrum subtraction(SS). Results Mathematical filtration techniques allowed each component to be obtained separately in either its zero, first, or derivative ratio form, allowing the resolution of spectra typical to the pure components present in Vitamin C Forte® tablets. The proposed methods were applied over a concentration range of 2–50, 2–30, and 10–100 µg/mL for RUT, HES, and ASC, respectively. Conclusions Recent methods for the analysis of binary mixtures, FZM and FD1M, were successfully applied for the analysis of ternary mixtures and compared to the novel FDRM. All were revealed to be specific and sensitive with successful application on pharmaceutical formulations. Validation parameters were evaluated in accordance with the International Conference on Harmonization guidelines. Statistical results were satisfactory, revealing no significant difference regarding accuracy and precision. Highlights Factorized methods enabled the resolution of spectra identical to those of pure drugs present in mixtures. Overlapped spectra of ternary mixtures could be resolved by spectrum subtraction coupled FDRM (SS-FDRM) or by successive application of FZM and FD1M.


2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.