primary secondary amine
Recently Published Documents


TOTAL DOCUMENTS

42
(FIVE YEARS 11)

H-INDEX

13
(FIVE YEARS 3)

Molecules ◽  
2021 ◽  
Vol 26 (21) ◽  
pp. 6727
Author(s):  
Saida Belarbi ◽  
Martin Vivier ◽  
Wafa Zaghouani ◽  
Aude De Sloovere ◽  
Valerie Agasse ◽  
...  

Pesticide extraction in rapeseed samples remains a great analytical challenge due to the complexity of the matrix, which contains proteins, fatty acids, high amounts of triglycerides and cellulosic fibers. An HPLC-MS/MS method was developed for the quantification of 179 pesticides in rapeseeds. The performances of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method were evaluated using different dispersive solid-phase extraction (d-SPE) sorbents containing common octadecylsilane silica/primary–secondary amine adsorbent (PSA/C18) and new commercialized d-SPE materials dedicated to fatty matrices (Z-Sep, Z-Sep+, and EMR-Lipid). The analytical performances of these different sorbents were compared according to the SANTE/12682/2019 document. The best results were obtained using EMR-Lipid in terms of pesticide average recoveries (103 and 70 of the 179 targeted pesticides exhibited recoveries within 70–120% and 30–70%, respectively, with low RSD values). Moreover, the limits of quantification (LOQ) range from 1.72 µg/kg to 6.39 µg/kg for 173 of the pesticides. Only the recovery for tralkoxydim at 10 μg/kg level was not satisfactory (29%). The matrix effect was evaluated and proved to be limited between −50% and 50% for 169 pesticides with this EMR-Lipid and freezing. GC-Orbitrap analyses confirmed the best efficiency of the EMR-Lipid sorbent for the purification of rapeseeds.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


Molecules ◽  
2021 ◽  
Vol 26 (2) ◽  
pp. 274
Author(s):  
Qiuhong Yang ◽  
Xiaohui Ai ◽  
Jing Dong ◽  
Yongtao Liu ◽  
Shun Zhou ◽  
...  

We developed a method for determination of imidacloprid and its metabolites 5-hydroxy imidacloprid, olefin imidacloprid, imidacloprid urea and 6-chloronicotinic acid in Procambarus clarkii (crayfish) tissues using quick, easy, cheap, effective, rugged, and safe (QuEChERS) and high-performance liquid chromatography-triple quadrupole mass spectrometry. Samples (plasma, cephalothorax, hepatopancrea, gill, intestine, and muscle) were extracted with acetonitrile containing 0.1% acetic acid and cleaned up using a neutral alumina column containing a primary secondary amine. The prepared samples were separated using reverse phase chromatography and scanned in the positive and negative ion multiple reaction-monitoring modes. Under the optimum experimental conditions, spiked recoveries for these compounds in P. clarkii samples ranged from 80.6 to 112.7% with relative standard deviations of 4.2 to 12.6%. The limits of detection were 0.02–0.5 μg·L−1, the limits of quantification were 0.05–2.0 μg·L−1 and the method of quantification was 0.05–2.0 μg·kg−1. The method is rapid, simple, sensitive and suitable for rapid determination and analysis of imidacloprid and its metabolites in P. clarkii tissues.


RSC Advances ◽  
2021 ◽  
Vol 11 (16) ◽  
pp. 9098-9111
Author(s):  
Salahudeen Shamna ◽  
C. M. A. Afsina ◽  
Rose Mary Philip ◽  
Gopinathan Anilkumar

Amino alkylation of an acidic α-proton of a carbonyl by formaldehyde and a primary/secondary amine or ammonia, affording a β-amino-carbonyl compound also known as a Mannich base is a valuable reaction. We focus on recent advances in Zn catalysed Mannich reactions.


Separations ◽  
2020 ◽  
Vol 7 (4) ◽  
pp. 52
Author(s):  
Nho-Eul Song ◽  
Young Sung Jung ◽  
Ji Yeon Choi ◽  
Minseon Koo ◽  
Hyo-Kyoung Choi ◽  
...  

Agricultural water is closely linked to surface and ground water as well as soil; hence, ensuring its safety is an important endeavor. We used the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) method to analyze multi-residue pesticides in agricultural water by using a combined-sorbent-based clean-up procedure. Among the various sorbents examined, clean-up using ENVI-Carb combined with a primary secondary amine sorbent delivered the highest recovery of multi-residue pesticides (>93.9%). While the developed method showed satisfactory linearity (R2 > 0.9991), precision, and specificity, recovery was low for pyrazolate (29.1%) and thidiazuron (59.2%). The limits of detection and quantification for the 55 pesticides targeted in this study were in 0.02–3.0 μg L−1 and 0.1–9.9 μg L−1, respectively. The developed method was used to identify and quantify multi-residue pesticides during sample analysis. The results suggest that the QuEChERS method employing a combination of ENVI-Carb and another sorbent can be applied for the effective analysis of multi-residue pesticides in agricultural water.


2020 ◽  
Vol 103 (6) ◽  
pp. 1498-1511 ◽  
Author(s):  
Bappa Ghosh ◽  
Narayan Kamble ◽  
Arijita Bhattacharyya ◽  
Chandrasekar Kandaswamy ◽  
Kaushik Banerjee

Abstract Background and objectives Turmeric is widely used as an ingredient of food and medicinal products. There exists no validated method for multi-residue analysis of pesticides in turmeric. Objective This study was undertaken to develop a simple and robust method for the quantitative determination of multi-class pesticides in turmeric powder and rhizome by GC-MS/MS. Method Initially, the samples were soaked in water for 30 min and homogenized to a fine paste. A portion of this paste (2 g) was extracted with acetonitrile (2 mL) and partitioned with hexane (2 mL) after adding 5 mL of 20% NaCl. The cleanup step involved dispersive solid phase extraction with graphitized carbon black (GCB, 5 mg/mL). Its performance was evaluated against primary secondary amine (PSA) and C18 sorbents. The cleaned extract was evaporated to dryness and reconstituted in ethyl acetate before GC-MS/MS analysis. The method was validated for a mixture of 208 multi-class pesticides at 10 ng/g and higher levels (i.e., 20 and 50 ng/g). Results The findings, which demonstrated a satisfactory recovery and precision (RSDs <20%) for all compounds at 10 ng/g and higher spiking levels, are aligned with the analytical quality control criteria of SANTE/12682/2019 guidelines. The cleanup effect of GCB was much superior to that of PSA, C18, and their combinations. The solvent exchange step with hexane was effective in removing co-extractives and minimizing matrix effects. Conclusions This method complies with the regulatory requirements and is fit-for-purpose for pesticide residue monitoring in turmeric. Highlights The study reports a validated GC-MS/MS method for multi-residue analysis of pesticides in turmeric for the first time. The method provided a high throughput analysis of multi-class pesticides in turmeric rhizome and powder matrices with satisfactory selectivity, sensitivity, accuracy, and precision.


Molecules ◽  
2019 ◽  
Vol 24 (11) ◽  
pp. 2093 ◽  
Author(s):  
Tomasz Tuzimski ◽  
Szymon Szubartowski

Background: Identification and quantitative determination of analytes released from the packaging material is undoubtedly a difficult and tricky task, requiring the chemical analyst to develop an individual approach to obtain reliable analytical information. Unfortunately, it is still challenging for scientists to determine bisphenols at trace or even ultra-trace levels in samples characterized by a very complex, and often variable, matrix composition. Objective: Optimization and application of QuEChERS/d-SPE coupled with HPLC-DAD (and LC-QqQ-MS) method for the simultaneous determination of bisphenols (A, S, F, B, BADGE and derivatives) in milk samples from a can and breast milk samples have been performed. Methods: Concerning the analysis of unconjugated analytes, after the thawing and shaking the sample (5 mL breast milk or 10 mL milk samples from a can), it was transferred into a 50 mL polypropylene centrifuge tube. For the analysis of the total amount of analytes, prior to the extraction with acetonitrile, a deconjugation step was implemented in a tube by adding to sample, the an Isotopically Labelled Internal Standard (IS) solution (50 ng/mL) and 1 mL of the enzymatic solution with the β-Glucuronidase (3500 U/mL). The mix was homogenized and incubated for 16–18 h at 37 °C. Next, 10 mL of acetonitrile, and a QuEChERS salt packet (4 g anhydrous MgSO4, 1 g NaCl) were added. After shaking and centrifugation, the total acetonitrile layer was isolated in a polypropylene tube evaporate to dryness, and reconstitute in 1.2 mL acetonitrile. During d-SPE step the extract was transferred into a 15 mL polypropylene tube with Z-Sep and primary secondary amine (PSA). Next, shake the tube, store in fridge, and centrifuge for 15 min. The acetonitrile supernatant was obtained with a pipette and evaporated to dryness. Mixture MeOH: water (20:80, v/v) were added to the dry residue and the extract was reconstitute in 200 μL and analyzed by HPLC-DAD and HPLC–QqQ-MS equipment. Conclusion: Six different salts during d-SPE step were evaluated such as: zirconium dioxide-based sorbent (Z-Sep, Z-Sep Plus), primary secondary amine (PSA), octadecyl (C18), EMR-Lipid, Chitin and also their mixtures. Negligible matrix interference was observed for most of the analytes due to application of Z-Sep and PSA in dispersive-solid phase extraction clean-up step. Extraction of target analytes was performed using QuEChERS/d-SPE cleanup, and presents good performance for selected analytes with recoveries in the range of 15–103% and relative standard deviations (RSD) less than 10% in breast milk samples.


Author(s):  
Chau Minh Huynh ◽  
Vu Dinh Thien Vo ◽  
Nguyen Thao Nguyen ◽  
Mai Anh Nguyen

Weak anion exchange sorbent based on cross-linked polystyrene with primary secondary amine group was prepared by substitution nucleophilic reaction (SN2) between methylene chloride group and 1,2-ethylene diamine. The effect of factors, namely the weight ratio of amine over methylene chloride, reaction time and temperature on nitrogen percentage were studied using experimental design approach. The amination yield rose as all of factors increased but was reduced while both temperature and time increased simultaneously. Nitrogen percentage of the products were varied from 4.0% to 6.3%. Sorbents with predicted capacity of 4.5%, 5.0%, 6.3%, and 6.5% were synthesized. The results showed that the actual capacities of the products were close to the predictions, especially for those in the experimental domain, indicating a good model that can be used to prepare sorbents of any desired capacity. The sorbent application ability of multiresidue pesticides analysis in food were initially investigated through both aspects: interference elimination and analyte content conservation.


Sign in / Sign up

Export Citation Format

Share Document