scholarly journals Optical Quality and Related Factors in Ocular Hypertension: Preliminary Study

2016 ◽  
Vol 2016 ◽  
pp. 1-5
Author(s):  
Yu-jing Wang ◽  
Yan-ning Yang ◽  
Lin-ying Huang ◽  
Bo Wang ◽  
Yu-can Han ◽  
...  

Background.To evaluate the optical quality and related factors in patients with ocular hypertension (OHT).Methods.This was a prospective case-control study. A total of 12 eyes with OHT and 20 control eyes underwent testing with Optical Quality Analysis System II (OQAS II) to evaluate the modulation transfer function cut off frequency (MTF cutoff), the Strehl 2D ratio (SR), objective scatter index (OSI), tear-film mean OSI (TFOSI), and the OQAS values (OV100%,OV20%, and OV9%).Results.The optical quality of patients with OHT declined, with lower MTF cutoff (OHT 36.86 ± 7.11 cpd , controls 48.50 ± 4.04 cpd,t=-4.60,P<0.05), lower SR (OHT 0.22 ± 0.04, controls 0.27 ± 0.05,t=-2.72,P<0.05), lower OV100% (OHT 1.26 ± 0.25, controls 1.61 ± 0.14,t=-4.03,P<0.05), lower OV20% (OHT 1.27 ± 0.27, controls 1.72 ± 0.20,t=-4.00,P<0.05), and lower OV9% (OHT 1.30 ± 0.25, controls 1.69 ± 0.32,t=-2.28,P<0.05). There were not any statistically significant differences in OSI and TFOSI. The MTF cutoff in patients with OHT was correlated significantly with age (r=-0.59,P<0.05).Conclusions.Optical quality of patients with OHT is reduced, with lower MTF cutoff, SR, OV100%, OV20%, and OV9%. MTF cutoff is negatively related to age.

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Zhonghao Ren ◽  
Liyan Xu ◽  
Qi Fan ◽  
Kaili Yang ◽  
Shengwei Ren ◽  
...  

Purpose. The study aimed to evaluate the visual quality of forme fruste keratoconus (FFK) and mild and moderate keratoconus by using an optical quality analysis system II (OQAS-II) and to explore the correlation between optical quality parameters and the disease progression. Methods. Twenty-one normal eyes, twenty-one FFK eyes, twenty-one mild keratoconus eyes, and twenty-one moderate keratoconus eyes were included in this prospective study. The optical quality parameters, such as object scatter index (OSI), modulation transfer function cutoff (MTF cutoff), strehl ratio (SR), and OQAS-II values at contrasts of 100% (OV-100), 20% (OV-20), and 9% (OV-9), were measured by OQAS-II. The repeatability of these parameters was analyzed by intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CVw). Correlations between optical quality parameters and mean central keratometry readings (Kmean) were evaluated. The sensitivity and specificity of the parameters were analyzed using the receiver operating characteristic (ROC). Results. All the optical quality parameters among four groups showed good repeatability (all ICC≥0.75). The MTF cutoff, SR, OV-100, OV-20, OV-9 in FFK, mild and moderate keratoconus eyes were significantly lower than those in the normal group (all P<0.05). The ROC analyses of the MTF cutoff, SR, OV-100, OV-20, and OV-9 showed significant area under the curve (AUC) in discriminating FFK form normal, mild keratoconus from FFK, and moderate keratoconus from mild keratoconus (all P<0.05). The OSI in mild and moderate keratoconus eyes were significantly higher than that in FFK and normal group (all P<0.05), while the OSI showed no significant difference between the FFK group and normal group (P>0.05). The ROC analyses of the OSI showed significant AUC in discriminating mild keratoconus from FFK and moderate keratoconus from mild keratoconus (all P<0.05). In addition, the MTF cutoff was closely correlated to Kmean in keratoconus eyes (r = −0.710, P<0.001). Conclusion. The repeatability of OQAS-II is good in measuring visual quality of normal as well as FFK, mild, and moderate keratoconus. The visual quality of the FFK, mild, and moderate keratoconus is worse than that in normal eyes. The OQAS-II has the potential value in screening FFK from normal eyes and might be a useful tool for evaluating the progression of keratoconus.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Jun Li ◽  
Zhe Yu ◽  
Hui Song

Purpose. To investigate the effects of capsulotomy shape on the visual acuity and visual quality after neodymium: yttrium aluminum garnet laser capsulotomy. Methods. In this study, a total of 42 eyes from 35 patients with posterior capsule opacification were divided into the circular and cruciate groups. The corrected distance visual acuity (CDVA), objective scatter index (OSI), modulation transfer function cutoff (MTF cutoff), Strehl ratio, and Optical Quality Analysis System values at contrasts of 100%, 20%, and 9% (OV-100, OV-20, and OV-9) were measured at precapsulotomy and 1 week and 1 month postcapsulotomy. The pseudophakic dysphotopsia questionnaire (PDQ) was used to evaluate the subjects’ satisfaction with treatment. Results. OSI values were significantly higher in the cruciate group than in the circular group at 1 week and 1 month after capsulotomy (P=0.013 and P<0.001). No significant difference was found in the OSI values between the two groups before capsulotomy (t = 0.52; P=0.61). The decrease in OSI was higher in the circular group than in the cruciate group at 1 week and 1 month after capsulotomy (P=0.036 and P=0.019). No significant differences were found in the Strehl ratio, MTF cutoff, CDVA, OV-100, OV-20, and OV-9 between the two groups at 1 week and 1 month after capsulotomy (P>0.05). The PDQ results showed that patients with circular-shaped capsulotomy complained less with intolerance of bright lights than those with cruciate-shaped capsulotomy. Conclusions. Circular-shaped capsulotomy can induce less intraocular light scattering and increase patient satisfaction.


2019 ◽  
Author(s):  
Yang Zhang ◽  
Ailing Bian ◽  
Qijun Hang ◽  
Qi Zhou

Abstract Purpose To investigate if optical quality assessed by Optical Quality Analysis System(OQAS)is a new factor for psychological disturbance and vision related quality of life(QoL) in Chinese patients with primary open angle glaucoma (POAG).Methods Cross-sectional study. OQAS, automated static perimetry, the Hospital Anxiety and Depression Scale (HADS) Questionnaire and the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) were used to assess optical quality, vision field, psychological health and QoL in 64 POAG patients. Correlation between the OQAS parameters and QoL or psychological health was analyzed by linear regression model.Results OQAS parameters, the modulation transfer function cut off frequency (MTF cutoff) and the mean OQAS values (mean OV), were significantly related to mean deviation (MD). Statistically significant correlation was also found between MTF cutoff, the mean OV and QoL in more than half of the NEI VFQ-25 subscale scores and the composite. The correlation coefficients between OQAS parameters and QoL were similar to those between MD and QoL in most of the subscale scores. HADS-Depression and HADS-Anxiety scores significantly correlated with MD in the worse eye, the composite and 3subscales of NEI VFQ-25, general health, social function and mental health, but uncorrelated with optical quality parameters measured by OQAS.Conclusions OQAS assessed optic quality is negatively related to MD and is a valid indicator for vision related QoL, but not for psychological health in our study group. OQAS might be an alternative or supplement to perimeter in POAG patients.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bo Lu ◽  
Weijie Zhu ◽  
Yu Fan ◽  
Dong Shi ◽  
Liwei Ma

Abstract Background A prospective cohort study was performed to evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. The objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = − 0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = − 0.669). In the logMAR CDVA ≤0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). In logMAR CDVA > 0.1 group, the area under the curve of the ROC of the OSI was 0.996 (P = 0.000). In logMAR CDVA ≤0.1 group, the area under the curve of the ROC of the OSI was 0.943 (P = 0.000). Conclusions The OSI was useful for evaluating of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and completely objective examination. Trial registration The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018).


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xiao-ling Jiao ◽  
Jun Li ◽  
Zhe Yu ◽  
Ping-hui Wei ◽  
Hui Song

Abstract Background To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia. Methods Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups. Results No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard. Conclusions Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.


2021 ◽  
pp. 112067212110021
Author(s):  
Javier Ruiz-Alcocer ◽  
Irene Martínez-Alberquilla ◽  
Amalia Lorente-Velázquez ◽  
José F Alfonso ◽  
David Madrid-Costa

Purpose: To objectively analyze the optical quality of the FineVision Toric intraocular lens (IOL) with two cylinder powers when different combinations of rotations and residual refractive errors are induced. Methods: This study assessed the FineVision Toric IOL with two different cylinder powers: 1.5 and 3.0 diopters (D). Three different rotation positions were considered: centered, 5° and 10° rotated. An optical bench (PMTF) was used for optical analysis. The optical quality of the IOLs was calculated by the modulation transfer function (MTF) at five different focal points (0.0, 0.25, 0.50, 0.75, and 1.00 D). Results: The MTF averaged value of the reference situation was 38.58 and 37.74 for 1.5 and 3.0 D of cylinder, respectively. For the 1.5 D cylinder, the combination of 5° of rotation with a defocus of 0.25, 0.50, 0.75, and 1.0 D induced a decrease on the MTF of 12.39, 19.94, 23.43, 24.23 units, respectively. When induced rotation was 10°, the MTF decrease was 17.26, 23.40, 24.33, 24.48 units, respectively. For the 3.0 D cylinder, the combination of 5° with 0.25, 0.50, 0.75, and 1.0 D of defocus, induced a decrease on the MTF of 12.51, 18.97, 22.36, 22.48 units, respectively. When induced rotation was 10°, the MTF decrease was: 18.42, 21.57, 23.08, and 23.61 units, respectively. Conclusion: For both FineVision Toric IOLs there is a certain optical tolerance to rotations up to 5° or residual refractive errors up to 0.25 D. Situations over these limits and their combination would affect the visual quality of patients implanted with these trifocal toric IOLs.


2012 ◽  
Vol 236-237 ◽  
pp. 839-843
Author(s):  
Xiao Meng Cui ◽  
Guang Xue Chen ◽  
Huan Mei Wang ◽  
Lin Lin Chen

In this study we present a new framework to assess line micro quality of multicolor prints adapted to a low-cost image quality analysis system based on common flatbed scanner. The contribution elements including quality metrics, measurement principle, applying methods and detection instrument, which were complemented and sorted in terms of ISO 13660 standard, were described and a case experiment was conducted to survey the output performance of both inkjet printer and xerographic printer, two most popular digital printing technologies. Their qualities were compared in details rendering angle such as width and straightness of line, raggedness and blurriness in line edges, as well as darkness and contrast in color. The results verify the efficiency and shortcomings of the framework. Meanwhile, the metric values let us take an investigation in the character of each digital printing technology in micron size.