scholarly journals Comparative Study of the Effects of 1% Atropine on the Anterior Segment

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Yue Zhou ◽  
Xiao Bo Huang ◽  
Qi Cai ◽  
Jun Jie Li ◽  
Yao Jia Xiong ◽  
...  

Purpose. To investigate the influences of atropine on changes in anterior segment geometry, as measured by ultrasound biomicroscopy in children. Methods. A prospective observational study was performed. Anterior segment parameters were obtained by UBM before and after the instillation of 1% atropine. Univariate linear regression was performed to identify the variables contributing to the changes in the trabecular meshwork-iris angle (TIA). Results. The study included 21 boys and 37 girls with a mean age of 10.79 ± 2.53 years. Anterior chamber parameters including the central anterior chamber depth, TIA, angle opening distance at 500 μm from the scleral spur, iris thickness 750 μm and 1500 μm from the scleral spur, trabecular-ciliary angle (TCA), trabecular-ciliary process distance, sclera-iris angle (SIA), and sclera-ciliary process angle significantly increased after cycloplegia ( P < 0.05 ). In contrast, the lens vault, iris cross-sectional area, and maximum ciliary muscle thickness significantly decreased after cycloplegia. Univariate analysis identified the change in TCA and the change in SIA and the TIA before mydriasis as determinants of the change in TIA. Conclusions. Atropine causes statistically significant changes in various anterior segment parameters in children. The change in anterior chamber angle is associated with the change in TCA and the change in SIA and the TIA before mydriasis.

2017 ◽  
Vol 11 (3) ◽  
pp. 86-91 ◽  

ABSTRACT Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student's t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 μm from scleral spur (AOD 500), trabecular—ciliary process distance (TCPD), iris—ciliary process distance (ICPD), and iris—zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral—iris angle (SIA), and scleral—ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris—lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91.


2021 ◽  
Vol 1 (3) ◽  
pp. 124-128
Author(s):  
Yadav Jitendra ◽  
De Tapas Kumar ◽  
Sah Sanjay Kumar ◽  
Anyam Sandip Das

Background: Accommodation changes ocular parameters, such as the anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD), which can reflect a risk of angle-closure glaucoma. Previous studies of changes in ocular anterior segment parameters, have used high diopters or maximum amplitude. Here, we focused on normal accommodation at a reading distance of 30‒40 cm. The aim of this study was to assess changes in anterior segment parameters during a normal accommodative state, using a Scheimpflug imaging system. Methods: In this cross-sectional study, 40 emmetrope subjects (mean ± SD of age: 22 ± 4.0 years) who met the inclusion criteria and provided informed consent were enrolled. Clinical history, refraction, amplitude of accommodation, slit lamp examination, Goldman applanation tonometry, and Pentacam investigations were performed on all subjects. Accommodative and non-accommodative targets were induced via the Pentacam. Two seconds were allowed for accommodation or relaxation prior to measurements in each eye. Results: Eighty normal eyes were evaluated; a small but statistically significant change in ACV, ACA, and PD during accommodation (P < 0.01, < 0.01, and < 0.05, respectively) was observed. The ACD did not change substantially with accommodation (P = 0.29). The mean ± SD values of ACV, ACD, ACA, and PD before and after accommodation were 151.85 ± 24.04 mm3 and 145.38 ± 23.30 mm3, 2.87 ± 0.28 mm and 2.86 ± 0.27 mm, 35.06° ± 3.68° and 33.84° ± 3.72°, and 3.46 ± 0.57 mm and 3.41 ± 0.53 mm, respectively. Conclusions: Accommodation changes ocular parameters, such as ACV, ACA, and PD, in healthy young emmetropes. Interestingly, the ACD remains unaltered during accommodation. Nevertheless, although these changes were statistically significant, they were not clinically significant in our study.


2019 ◽  
Vol 30 (3) ◽  
pp. 462-468 ◽  
Author(s):  
Yi Zhu ◽  
Jing Zhang ◽  
Haobin Zhu ◽  
Jili Chen ◽  
Jibo Zhou

Purpose:To evaluate the vault change and anterior segment movement induced by mydriasis in moderate-to-high myopic eyes with implantable collamer lenses (ICL).Setting:Shanghai, ChinaDesign:A prospective consecutive observational study.Methods:A total of 45 eyes of 24 patients with ICL V4 implantation and 128 eyes of 65 patients with ICL V4c implantation were included and analyzed. Anterior chamber depth, posterior corneal endothelium-to-ICL distance, and vault before and after mydriasis were measured by Pentacam (Oculus, Wetzlar, Germany) at 1, 3, and 6 months after surgery.Results:Significant vault increases and anterior chamber depth increases induced by mydriasis were noted in both ICL V4 and V4c groups at 1, 3, and 6 months postoperatively. The corneal endothelium-ICL distance increased significantly in eyes with implanted ICL V4c after mydriasis at 3 and 6 months. Moreover, mydriasis-induced vault increases were greater in the ICL V4 group than in the ICL V4c group at 3 and 6 months. In eyes with implanted ICL V4c, mydriasis-induced vault increases were significantly greater at 1 month than at 3 and 6 months.Conclusion:Mydriasis results in a general vault increase in eyes with implanted ICLs. The adjustment of the pressure equilibrium via the central hole of the ICL V4c has an important role in vault change. The mydriasis-induced vault increases tend toward stability after 3 months postoperatively. Mydriasis is relatively safe in eyes with ICL implantation.


2021 ◽  
Vol 8 ◽  
Author(s):  
Guihua Xu ◽  
Guanrong Wu ◽  
Zijing Du ◽  
Shanqing Zhu ◽  
Yunxiang Guo ◽  
...  

Purpose: To investigate the distribution of white-to-white (WTW) corneal diameter and anterior chamber depth (ACD) in Chinese myopia patients.Methods: This was a cross-sectional observational study conducted at five ophthalmic centers. Anterior segment biometry was performed in 7,893 eyes of the 7,893 myopic patients using Pentacam, and the WTW and ACD were recorded. The distribution patterns of WTW and ACD were evaluated and the correlation between WTW and ACD was analyzed statistically.Results: There were 4416 (55.95%) males and 3477 (44.05%) females. The age of the study population was 25.14 ± 5.41 years. Distribution of WTW was slightly positively skewed (Skewness = 0.0076, Kurtosis = 0.3944, KS P = 0.020) with a mean of 11.65 ± 0.38 mm and a 95% normal range of 10.91–12.39 mm. A significant difference in WTW was found among different myopia groups (P &lt; 0.001). The ACD was normally distributed (Skewness = 0.899, Kurtosis = 0.027, KS P = 0.086). The mean ACD was 3.25 ± 0.26 mm and the 95% normal range of was 2.74–3.75 mm. A significant difference in ACD was also found among different myopia groups (P = 0.030). There was a significant correlation between WTW and ACD (r = 0.460, P &lt; 0.001).Conclusions: In our study, 95% of the Chinese myopic patients had a WTW within 10.91–12.39 mm and an ACD within 2.74–3.75 mm. ACD and WTW were significantly different among different myopia, gender and age groups. WTW was positively correlated with ACD.


2021 ◽  
Vol 18 (4) ◽  
pp. 827-832
Author(s):  
A. N. Kulikov ◽  
E. V. Danilenko ◽  
A. A. Dzilikhov

Purpose: To assess the capsular tension ring implantation effect on the IOL position according to different devices in the long term period after uncomplicated phacoemulsification.Patients and methods. The study enrolled 234 patients (273 eyes) with cataract without zonular weakness. A standard examination, optical biometry and Sheimpflug imaging were performed preoperatively. In all cases phacoemulsification with IOL implantation, supported by CTR in 11 % of cases (30 eyes) was performed in 1, 3, and 6 months after surgery autorefractometry, visual acuity, biometry, OCT of anterior segment and ultrasound biomicroscopy were provided.Results. By the 3rd month a small shift of IOL towards the retina was revealed without any refraction changes. In cases with CTR implantation the anterior chamber depth was stable. According to OCT data the angle of IOL tilt in the horizontal meridian gradually decreased, the dynamics was significant from 3 months (p = 0.032). There were no changes in the vertical direction. After CTR implantation IOL position did not significantly change. There was no difference between the groups (p > 0.05) by 6 month. The phenomenon of IOL “deflection” according to OCT data was observed in 20.87 % of cases was in 1 month after operation. In the presence of CTR its frequency decreased to 15.00 %, and in the absence, it increased to 21.63 %. In every fifth case of deformation the measurements did not give us a definite reason to further consider it a “deflection” by 6 months after the operation. In 4.24 % of cases fact of IOL “deflection” was absent at the first month but appeared by the 6 month. There was not any case of CTR implantation among described cases of IOL position change.Conclusion. Fluctuation of anterior chamber depth is observed up to 3 months after uncomplicated phacoemulsification. Changes in IOL tilt angle occur throughout the observation period with a significant decrease in the horizontal plane by 6 month. Implantation of the CTR should stabilize anterior chamber depth, block the IOL tilt and also reduce the percentage of IOL deflection cases in the defined group.


2013 ◽  
Vol 94 (6) ◽  
pp. 853-858
Author(s):  
A A Ryabtseva ◽  
M P Yugaj ◽  
N S Nikitina

Aim. To study the changes of anatomic and topographic characteristics of the eye anterior segment after uncomplicated cataract phacoemulsification using corneal incision with intraocular soft lens implantation. Methods. The data of ultrasound biomicroscopy and noncontact tonometry of 58 eyes (56 patients, 32 females, 24 males aged 54 to 78 years) before and after cataract phacoemulsification were analyzed. Paitents with survived ocular trauma, refractive keratoplasty, glaucoma, uveitis, and surgical complications (incomplete capsulorrhexis, posterior capsule rupture, ciliary zonule disinsertion, corneal burn). Apart from the common examinations (visual acuity testing, tonometry, tonography, eye A- and B-ultrasonography, biomicroscopy), all patients underwent eye ultrasound biomicroscopy. Results. Anterior chamber depth increased from 2.73±0.10 to 4.17±0.06 mm (p ≤0.001). Trabecula-iris distance measured at 500 μm from the scleral spur, increased from 0.38±0.02 to 0.47±0.02 mm (p ≤0.001). Anterior chamber angle increased from 28.69±1.87 to 42.73±1.56 degrees (p ≤0.001), the angle between the iris and the sclera increased from 32.78±1.39 to 41.36±0.84 degrees (p ≤0.001), the angle between the sclera and ciliary processes increased from 39.48±1.29 to 45.30±1.16 degrees (p ≤0.001). Intraocular pressure according to the non-contact tonometry data decreased from 18.16±1.29 to 13.55±0.95 mm Hg (p ≤0.001). Conclusion. Anterior chamber depth, trabecula-iris distance, anterior chamber angle, the angle between sclera and iris and the angle between sclera and ciliary processes increased significantly after phacoemulsification with intraocular lens implantation. Intraocular pressure decreased significantly according to the non-contact tonometry data.


2016 ◽  
Vol 27 (1) ◽  
pp. 31-38 ◽  
Author(s):  
Erkan Ünsal ◽  
Kadir Eltutar ◽  
İlkay K. Muftuoglu

Purpose To evaluate morphologic changes in the anterior segment using ultrasound biomicroscopic imaging (UBM) after phacoemulsification and foldable intraocular lens implantation (IOL). Methods Thirty-six patients with a mean age of 68.68 ± 8.44 years (range 51-89) who had phacoemulsification and foldable IOL implantation were included in this prospective study. Several anterior segment parameters including aqueous depth (AQD), trabecular meshwork-iris angle (TIA), ciliary body thickness (CBT), sclera thickness (ST), trabecular meshwork-ciliary process distance (T-CPD), iris-ciliary processes distance (I-CPD), and iris thickness (IT) were measured using UBM preoperatively and at postoperative month 2. Results There was a significant increase in AQD (p<0.001) and TIA (p<0.001) at postoperative month 2. However, CBT, ST, T-CPD, I-CPD, and IT did not significantly change (p>0.05) during the study period. Conclusions Removal of the crystalline lens results in change in the anterior segment parameters. Our results confirmed that UBM is a helpful option for the analysis of anterior segment structures both qualitatively and quantitatively.


2016 ◽  
Vol 27 (4) ◽  
pp. 417-422 ◽  
Author(s):  
José Ignacio Fernández-Vigo ◽  
Lucía De-Pablo-Gómez-De-Liaño ◽  
Cristina Fernández-Vigo ◽  
Inés Sánchez-Guillén ◽  
Enrique Santos-Bueso ◽  
...  

Purpose To determine the prevalence of trabecular-iris contact (TIC) and quantify this contact in healthy Caucasian individuals using Fourier-domain optical coherence tomography (FD-OCT). Methods For this cross-sectional study, 2,012 eyes of 1,006 healthy subjects were recruited among individuals undergoing a routine ophthalmologic checkup. In each participant, age, sex, intraocular pressure, and spherical refractive error were first recorded along with anterior chamber depth and volume, central corneal thickness measured with the Pentacam, and axial length with the IOLMaster. Anterior chamber angle variables and the presence of TIC in the horizontal quadrants were determined by anterior segment FD-OCT (RTVue 100®). When TIC was observed, TIC length (TICL) and its percentage in relation to the length of the trabecular meshwork (TICL percentage) were also measured. Results Trabecular-iris contact in the horizontal quadrants was observed in 34 eyes of 25 patients, representing 1.6% of the total number of eyes examined. In this subgroup of individuals, mean age was 55.8 years, 84% were women, and spherical refractive error ranged from -0.25 to 8.25 D. Eyes with TIC showed an angle width of less than 23.2 degrees and axial length shorter than 23.7 mm. Mean TICL was 239 ± 79 μm (103-495 μm) and mean TICL percentage was 46.9% ± 13.9% (17.2%-76.3%). Conclusions The prevalence of TIC was low in this population. Fourier-domain optical coherence tomography emerged as useful to assess its prevalence and quantify the extent of TIC.


2018 ◽  
Vol 103 (7) ◽  
pp. 960-965 ◽  
Author(s):  
Ramanjit Sihota ◽  
Neha Kamble ◽  
Ajay K Sharma ◽  
Anju Bhari ◽  
Amisha Gupta ◽  
...  

AimTo evaluate the accuracy of a new, modified grading scheme involving a short vertical slit beam, at the inferior angle for peripheral anterior chamber depth (PAC) and angle estimation and its correlation with anterior segment optical coherence tomography (ASOCT).MethodsA cross-sectional study of consecutive phakic patients, above 40 years of age, was performed. Using a short, vertical slit beam not reaching the pupil, the inferior angle at the sclerolimbal junction was evaluated, photographed and assessed by a ratio of peripheral anterior chamber depth to peripheral corneal thickness (PAC:PCT) and iridocorneal angle (ICA) on ImageJ software. The inferior angle at the same meridian was also recorded on ASOCT.ResultsBased on the PAC:PCT ratio, the subjects were divided into four groups: I (<1/4), II (1/4-1/2), III (>1/2–1) and IV (>1). The clinically assessed angle by short vertical slit beam correlated well with ASOCT values, trabecular-iris angle (TIA) (r=0.918; p<0.001) and scleral spur angle (r=0.903, p<0.001). The mean difference between ICA and TIA on ASOCT was 0.7970; 95% limits of agreement:−5.7670 to 7.3610 (±1.96 SD). For angles graded narrow on ASOCT (TIA <200), using a cut-off of peripheral PAC:PCT <1/4, the area under the curve was 0.918 with a sensitivity of 85.2% and a specificity of 88.2%. There was good agreement between ImageJ parameters with those assessed subjectively on photograph of the slit beam examination by a glaucoma fellow (weighted kappa=0.74) as compared with a general ophthalmologist, where there was moderate agreement (weighted kappa=0.57).ConclusionA short, vertical slit lamp beam evaluation at the inferior angle is an easy and relatively accurate method for both peripheral anterior chamber depth and angle assessment. It correlated well with ASOCT and can be used as a more reliable screening tool to identify eyes with possibly occludable angles.


2019 ◽  
Vol 16 (3) ◽  
pp. 350-354
Author(s):  
O. L. Fabrikantov ◽  
S. I. Nikolashin ◽  
E. S. Pirogova

Purpose: tо evaluate the diagnostic capabilities of optical coherence tomography (OCT), Scheimpflug camera and ultrasound biomicroscopy (UBM) in examining topography of the ocular anterior segment and lens in mature intumescent cataract. Patients and methods. 23 eyes with mature intumescent cataract were examined using OCT (RTVue-100, Optovue, USA), Scheimpflug camera (Pentacam HR, Oculus, Germany) and UBM (UD 8000, Tomey, Japan). We examined the anterior chamber depth, profile and magnitude of the anterior chamber angle, distance “trabecula-iris at 500 microns”, thickness of the liquid lenticular mass layer, lens thickness, Zinn ligament length within four segments, equatorial angle. Results. We managed to measure the anterior chamber depth using UBM and Scheimpflug camera. UBM measurement was 1.96 ± 0.14 mm, Scheimpflug camera — 1.91 ± 0.11 mm. We revealed narrowing of the anterior chamber angle up to 11.54 ± 2.19° in UMB examination, to 11.49 ± 2.17° in OCT measuring and to 11.63 ± 2.21° in examining by Scheimpflug camera. Distance “trabecula-iris 500” was 0.212 ± 0.037 mm in UMB examination, 0.218 ± 0.042 mm — by means of OCT, Scheimpflug camera measurement was unsuccessful. The rest parameters were examined only by UBM. The lens thickness was 5.26 ± 0.13 mm. The anterior layer of liquid lenticular mass was 0.85 ± 0.06 mm. Zinn ligament length in the outer segment was 0.708 ± 0.072 mm, in the internal segment — 0.731 ± 0.089 mm, in the superior segment — 0.704 ± 0.084 mm, in the inferior segment — 0.876 ± 0.089 mm. The equatorial angle in two opposite segments was 32.52 ± 0.92°. Conclusion. Ultrasound biomicroscopy has the biggest value in examining topography of the ocular anterior segment and lens in mature intumescent cataract, since only this method allows achieving the whole complex of data necessary to evaluate the swelling lens parameters. This can serve as a basis for developing the appropriate tactics of surgical intervention.


Sign in / Sign up

Export Citation Format

Share Document