scholarly journals An Efficient Solid-Phase Extraction-Based Liquid Chromatography Method to Simultaneously Determine Diastereomers α-Tocopherol, Other Tocols, and Retinol Isomers in Infant Formula

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Baifen Huang ◽  
Zengxuan Cai ◽  
Jingshun Zhang ◽  
Jiaojiao Xu

The separation and simultaneous quantitation of diastereomers of DL-α-tocopherol, eight tocol forms, and retinols (trans and cis) have been conducted by reversed-phase liquid chromatography followed by solid-phase extraction. A chiral silica stationary phase modified with polysaccharide derivative on the monodisperse macroporous silica gel (Unichiral OD-5H column, 150 mm × 4.6 mm, 5 μm, NanoMicro Technology Co., Ltd.) was employed for eluting each target compound. Instead of conventional solvent extract, a green and eco-friendly solid-phase extraction column, packing with nonpolar polystyrene divinylbenzene, was optimized in terms of capacity and solvent used in steps. Validation of the method was examined and confirmed to be satisfactory, with excellent linearity regression (r > 0.9999), acceptable accuracy (74.66%∼112.92%), and precision (0.20%∼10.52%) results. Limit of detection ranged from 0.05 mg·kg−1 (retinols) to 0.4 mg·kg−1 (tocols). The method was checked by infant formula reference material SRM 1849a as well, which illustrated good agreement of mass fraction with certified value and enriched the important isomer data.

Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2123
Author(s):  
Luboš Fical ◽  
Maria Khalikova ◽  
Hana Kočová Vlčková ◽  
Ivona Lhotská ◽  
Zuzana Hadysová ◽  
...  

Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.


2011 ◽  
Vol 89 (4) ◽  
pp. 517-523 ◽  
Author(s):  
Ke-Jing Huang ◽  
Cong-Hui Han ◽  
Ying-Ying Wu ◽  
Chao-Qun Han ◽  
De-Jun Niu ◽  
...  

A simple and efficient solid-phase extraction – spectrofluorimetric method has been developed to determine glutathione (GSH). Fluorescent probe N-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-yl)methyl)iodoacetamide (BODIPY Fl-C1-IA) was used as the derivatization reagent. The procedure was based on a BODIPY Fl-C1-IA selective reaction with GSH to form the highly fluorescent product BODIPY Fl-C1-IA–GSH, using a solid-phase extraction column and spectrofluorimetric determination. The variables affecting analytical performance were studied and optimized. The calibration graph using the preconcentration system for GSH was linear over the range of 1–200 nmol/L with a limit of detection of 0.05 nmol/L (signal-to-noise ratio = 3). The relative standard deviation for six replicate determinations of GSH at the 100 nmol/L concentration level was 3.9%. The method was applied to water samples and average recoveries between 87.5% and 111.5% were obtained for spiked samples.


2004 ◽  
Vol 87 (4) ◽  
pp. 937-942 ◽  
Author(s):  
Harumi Oshima ◽  
Eiji Ueno ◽  
Isao Saito ◽  
Hiroshi Matsumoto

Abstract A simple solid-phase extraction (SPE) method was developed for the liquid chromatography (LC) determination of pheophorbide (Phor) a and pyropheophorbide (Pyro) a in health foods such as chlorella, spirulina, etc. The food sample was extracted with 85% (v/v) acetone. The extract was acidified with hydrochloric acid and loaded on a C18 cartridge. After washing with water, Phor a and Pyro a were eluted with the LC mobile phase. Phor a and Pyro a were separated by isocratic reversed-phase LC and quantitated by fluorescence detection. The recoveries for spiked samples of chlorella and the extract were 87.1–102.0%. Commercial health foods (chlorella, spirulina, aloe, kale, Jews mallow, and green tea leaves) were analyzed using the SPE method. The values found for Phor a and Pyro a ranged from 2 to 788 μg/g and from <1 to 24 μg/g, respectively. There was no significant difference between the SPE method and the official method in Japan (spectrophotometry after liquid–liquid extraction). The advantages of the SPE method are the short extraction times, lack of emulsions, and reduced consumption of organic solvents compared with the official method in Japan. The SPE method is considered to be useful for the screening of Phor a and Pyro a in health foods.


Sign in / Sign up

Export Citation Format

Share Document