A Overlapping Carrier Based SPWM for a 5-Level Cascaded H-bridge Multilevel Inverter

Author(s):  
Kureve D. Teryima ◽  
Goshwe Y. Nentawe ◽  
Agbo O. David

<p>This paper proposes a switching control for a cascaded H-bridge inverter structure with reduced switches which is used to improve the THD performance of a single phase five level CHB MLI. The multi level inverter is simulated for the conventional carrier overlapping APOD and the proposed carrier overlapping APOD Pulse Width Modulation (PWM) switching control technique. The total harmonic distortion (THD) of the output voltages are observed for both PWM control techniques. The performance of the symmetric CHB MLI is simulated using MATLAB-SIMULINK. It is observed that the proposed carrier overlapping APODPWM provides output with relatively low THD as compared to the conventional carrier overlapping APODPWM.</p>

Author(s):  
Kureve D. Teryima ◽  
Goshwe Y. Nentawe ◽  
Agbo O. David

This paper proposes a switching control for a cascaded H-bridge inverter structure with reduced switches which is used to improve the THD performance of a single phase five level CHB MLI. The multi level inverter is simulated for the conventional carrier overlapping APOD and the proposed carrier overlapping APOD Pulse Width Modulation (PWM) switching control technique. The total harmonic distortion (THD) of the output voltages are observed for both PWM control techniques. The performance of the symmetric CHB MLI is simulated using MATLAB-SIMULINK. It is observed that the proposed carrier overlapping APODPWM provides output with relatively low THD as compared to the conventional carrier overlapping APODPWM.


2018 ◽  
Vol 7 (3.1) ◽  
pp. 42
Author(s):  
B Kandavel ◽  
G Uvaraj ◽  
M Manikandan

This paper presents comparative study of Total Harmonic Distortion (THD) and its individual harmonic contents without grid and with grid for Diode clamped multi level inverter (DCMLI) and Flying capacitor clamped multilevel inverter (FCMLI) based Doubly Fed Induction Generator (DFIG) employing PI and Fuzzy logic controller (FLC). Simple method to control for a variable speed wind energy conversion system with a DFIG is connected to the grid through a diode rectifier and a diode clamped multilevel inverter (DCMLI). The DC-link voltage is controlled through a DC-DC boost converter to keep the DC voltage at constant value. Inverter is controlled by sinusoidal pulse width modulation technique, which supplies power to the grid. The THD and its harmonic content are studied for different wind speeds. DFIG fed flying capacitor multi level inverter (FCMLI) based WECS connected to load as well as grid. FCMLI is controlled through sinusoidal pulse width modulation. Voltage and current harmonics are studied. The results of both multilevel inverters are compared. It shows that the level of harmonic content of two types of multilevel inverters working at different wind speeds indicates that Total Harmonic Distortion (THD) for DCMLI has given best results.  


2015 ◽  
Vol 15 (2) ◽  
pp. 229
Author(s):  
P. Sureshpandiarajan ◽  
S.P Natarajan ◽  
C.R. Balamurugan ◽  
K. Ramasamy

<p class="IEEEAuthorAffiliation">This work presents the comparison of various Pulse Width Modulation (PWM) techniques for the chosen single phase half bridge FCMLI (Flying Capacitor Multi Level Inverter). In this paper, a single phase half bridge flying capacitor multilevel inverter is controlled with sinusoidal, THI (Third Harmonic Injection), Trapezoidal and TAR (Trapezoidal Amalgamated Reference)reference with Equal Amplitude Carriers (EAC) and UEAC (Un Equal Amplitude Carriers). The proposed EAC and UEAC is applied for various PWM strategies. The PWM methods used for the analysis are PD (Phase Disposition) PWM, POD (Phase Opposition and Disposition) PWM, APOD (Alternative Phase Opposition and Disposition) PWM and CO (Carrier Overlapping) PWM with EAC and UEAC. For all the PWM methods and references the UEAC produces less THD and higher fundamental RMS (Root Mean Square) values except for m<sub>a</sub> =1. For m<sub>a</sub> =1 the EAC provides less THD (Total Harmonic Distortion) and higher fundamental RMS (Root Mean Square) values for all the PWM methods and references. To validate the developed technique, simulations are carried out through Power System Block Set.</p>


Author(s):  
N. Susheela ◽  
P. Satish Kumar

<p>The popularity of multilevel inverters have increasing over the years in various applications without use of a transformer and has many benefits. This work presents the performance and comparative analysis of single phase diode clamped multilevel inverter and a hybrid inverter with reduced number of components. As there are some drawbacks of diode clamped multilevel inverter such as requiring higher number of components, PWM control method is complex and capacitor voltage balancing problem, an implementation of hybrid inverter that requires fewer components and less carrier signals when compared to conventional multilevel inverters is discussed. The performance of single phase diode clamped multilevel inverter and hybrid multilevel inverter for seven, nine and eleven levels is performed using phase disposition, alternate phase opposition disposition sinusoidal pulse width modulation techniques. Both the multilevel inverter are implemented for the above mentioned multicarrier based Pulse Width Modulation methods for R and R-L loads.  The total harmonic distortion is evaluated at various modulation indices. The analysis of the multilevel inverters is done by simulation in matlab / simulink environment.</p>


2014 ◽  
Vol 622 ◽  
pp. 133-139
Author(s):  
Jayabal Gayathri Monicka ◽  
Venkatesan Jamuna ◽  
Kannakumar Hemalatha

This paper presents performance features of Symmetric and Asymmetric Cascaded Multilevel inverter. Both the Phase shifted and level shifted multicarrier pulse width modulation (MCPWM) technique are used in MLI. The best harmonic performance is improved by Level-shifted multicarrier modulations technique . The objective of this work to propose MCPWM Technique for multilevel inverter with equal and unequal DC sources. The Performances indices like Total Harmonic Distortion (THD), reduction of switches and number of DC Sources is considered. An appropriate method to achieve the MC modulation technique is also presented in this paper.


Author(s):  
M. H. Yatim ◽  
A. Ponniran ◽  
M. A. Zaini ◽  
M. S. Shaili ◽  
N. A. S. Ngamidun ◽  
...  

The purpose of this study is to analyze the operation and design of symmetrical and asymmetrical multilevel inverter structures with reduced number of switching devices. In this study, the term of conventional inverter is defined as a single cascaded inverter. Specifically, the inverter operates in three complete loops and only produces 2-level and 3-level of output voltages. Usually, cascaded structure suffers from the high total harmonic distortion. Thus, by considering multilevel structure of inverter, low total harmonic distortion reduction and voltage stress reduction on switching devices can be archived. Sinusoidal pulse width modulation and modified square pulse width modulation are used as modulation techniques in switching schemes of the designed multilevel inverters. The findings indicate that, the designed multilevel structure cause low total harmonics distortion at the output voltage. Furthermore, the asymmetrical structure is producing the same output voltage levels with reduced number of switching devices compared to the symmetrical structure is experimentally confirmed. The findings show that the total harmonic distortion for 7-level (symmetrical) and 9-level (asymmetrical) are 16.45% and 15.22%, respectively.


Author(s):  
B. Ravi Teja

This paper presents the design of gate drive circuit for controlling of multilevel inverter (MLI) with Phase Disposition (PD), Phase Opposition Disposition (POD) pulse width modulation (PWM) switching control technique.


2019 ◽  
Vol 8 (2) ◽  
pp. 2650-2659

Multi-level inverter technology emerges as extremely significant choice in region of high-power medium voltage energy control. The multi-level inverter(MLI) generate a quasi sinusoidal voltage from various level of dc voltage. The proposed inverter design for 21 level cascaded MLI inverter by using Level Shifted-Sinusoidal Pulse Width Modulation (LS-SPWM) technique with new carrier and evaluate the Total Harmonic Distortion(THD). The proposed inverter design has the least number of components to lessen the cost and get better reliability of converter for medium power applications. The presented control techniques are applicable to cascaded H-bridge 21 level inverter to get better voltage regulation and thereby, lead the better efficiency,reliability and economic improvement. The selected pattern gave superior result in Total Harmonic distortion.


Author(s):  
V.Jamuna Venkatesan ◽  
Gayathrimonicka Subarnan

<p>This paper presents performance features of Asymmetric Cascaded Multilevel inverter. Multilevel inverters are commonly modulated by using multicarrier pulse width modulation (MCPWM) techniques such as phase-shifted multicarrier modulation and level-shifted multicarrier modulation. Amongst these level-shifted multicarrier modulations technique produces the best harmonic performance. This work studies about multilevel inverter with unequal DC sources using level shifting MCPWM technique. The Performances indices like Total Harmonic Distortion (THD), reduction of switches and number of DC Sources are considered. A procedure to achieve the appropriate level shifting is also presented is this paper.</p>


2018 ◽  
Vol 7 (2.6) ◽  
pp. 327
Author(s):  
Wahyu Mulyo Utomo ◽  
Afarulrazi Abu Bakar ◽  
Suhaila Alias ◽  
Sim Sy Yi ◽  
Muhammad Ikhsan Setiawan ◽  
...  

Recently, almost all industrial devices are mostly built on electronic devices which are precisely sensitive to harmonic. In order to meet the requirement from the industries demand aimed at a free-harmonics and high power rating source is remarkably increased in past few years. An inverter which a device or electric circuit that convert direct current to alternating current is one of the electronic devices that give concern to researchers for improvement of generating a neat power source. The inverter can be categorized into a single level and multilevel inverter. As compared to single level inverter, multilevel inverter offers minimum harmonic distortion and higher power output. This paper presents a model of multilevel inverter using 7-level Cascaded H-Bridge of multilevel DC-AC inverter to reduce total harmonic distortion with different sinusoidal pulse width modulation such as phase disposition and phase opposition disposition. Simulation output of single phase multilevel inverter cascaded H-bridge are analysed and verified in the Matlab/Simulink software. The result show that the 7-level cascaded H-Bridge multilevel inverter with phase disposition technique generate less total harmonic distortion if it is compared to the phase opposition disposition technique. 