Reduced coagulation at high altitude identified by thromboelastography

2012 ◽  
Vol 107 (06) ◽  
pp. 1066-1071 ◽  
Author(s):  
Daniel Martin ◽  
Jim Pate ◽  
Andre Vercueil ◽  
Patrick Doyle ◽  
Michael Mythen ◽  
...  

SummaryThe impact of hypoxaemia on blood coagulation remains unclear despite use of a variety of measures to address the issue. We report the first use of thromboelastography (TEG) at high altitude to describe the dynamics of clot formation in whole blood samples. Seventeen healthy volunteers ascended to 5,300 m following an identical ascent profile; TEG measurements at 4,250 m and 5,300 m were compared with those from sea level. Peripheral oxygen saturation (SpO2) and haematocrit were also measured. Ascent resulted in a decline in SpO2 from 97.8 (± 1.2) % at sea level to 86.9 (± 3.3) % at 4,250 m and 79.5 (± 5.8) % at 5,300 m (p<0.001); haematocrit rose from 43.7 (± 2.8) % at sea level, to 46.7 (± 3.9) % and 52.6 (± 3.2) % at 4,250 m and 5,300 m, respectively (p<0.01). TEG reaction (R)-time and kinetic (K)-time were both increased at 5,300 m compared to sea level, 8.95 (± 1.37) minutes (min) to 11.69 (± 2.91) min (p=0.016) and 2.40 (± 0.66) min to 4.99 (± 1.67) min (p<0.001), respectively. Additionally the alpha (α)- angle was decreased from 57.7 (± 8.2) to 51.6 (± 6.4) (p<0.001). There was no change in maximum amplitude (MA) on ascent to altitude. These changes are consistent with an overall pattern of slowed coagulation at high altitude.

2016 ◽  
Vol 45 ◽  
pp. 64-72 ◽  
Author(s):  
Lisa M. Katz ◽  
Louise A. Mooney ◽  
Katie Gough ◽  
Charlotte L. McGivney ◽  
Maureen McCoughlan ◽  
...  

Author(s):  
Florian Prüller ◽  
Andreas Münch ◽  
Astrid Preininger ◽  
Reinhard Bernd Raggam ◽  
Yvonne Grinschgl ◽  
...  

AbstractFibrinogen-based clot firmness is reported as the maximum amplitude (MA) when using the citrated functional fibrinogen (CFF) assay in thrombelastography (TEG), and as the maximum clot firmness (MCF) together with several clot amplitude parameters when using the FIBTEM assay in thromboelastometry (ROTEM). Concern is currently being raised that these two tests have different platelet inhibiting performance and consequently provide different values. This is relevant for the clinical setting of fibrinogen replacement. We aim herein to compare the parameters of these two fibrinogen-based clot quality tests and their correlation with the plasma fibrinogen level as determined by the Clauss method.In total 261 whole blood samples taken from 163 clinical routine surgical patients were analyzed with TEG 5000 and ROTEM tests, and correlation with Clauss fibrinogen level was assessed.: Using TEG, the overall fibrin-based clot firmness measured in the CFF assay was significantly higher than the MCF measured by FIBTEM assay. Both assays showed significantly positive correlations with the fibrinogen levels measured using the Clauss method. However, individual values of Clauss fibrinogen concentration corresponded with different values for the two viscoelastometric tests; e.g. within the range of 1.9–2.1 g/L Clauss fibrinogen the median of CFF MA was 16.3 mm whereas FIBTEM MCF was 12.0 mm.: We showed herein by measurements of citrated whole blood samples from surgical patients that CFF MA values were different from FIBTEM MCF values measured in the same sample. Awareness that these whole blood assays provide different clot amplitude results is mandatory, particularly if they are being considered as tools for guiding fibrinogen supplementation. Thromboembolic side effects caused by a potentially too high fibrinogen substitution must also kept in mind in this context.


2010 ◽  
Vol 41 (02) ◽  
Author(s):  
N Shazi ◽  
A Böss ◽  
HJ Merkel ◽  
F Scharbert ◽  
D Hannak ◽  
...  

Separations ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 78
Author(s):  
Sevasti Karampela ◽  
Jessica Smith ◽  
Irene Panderi

An ever-increasing need exists within the forensic laboratories to develop analytical processes for the qualitative and quantitative determination of a broad spectrum of new psychoactive substances. Phenylethylamine derivatives are among the major classes of psychoactive substances available on the global market and include both amphetamine analogues and synthetic cathinones. In this work, an ultra-high-performance liquid chromatography-positive ion electrospray ionization tandem mass spectrometric method (UHPLC-ESI-MS/MS) has been developed and fully validated for the determination of 19 psychoactive substances, including nine amphetamine-type stimulants and 10 synthetic cathinone derivatives, in premortem and postmortem whole blood. The assay was based on the use of 1 mL premortem or postmortem whole blood, following solid phase extraction prior to the analysis. The separation was achieved on a Poroshell 120 EC-C18 analytical column with a gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 9 min. The dynamic multiple reaction monitoring used in this work allowed for limit of detection (LOD) and lower limit of quantitation (LOQ) values of 0.5 and 2 ng mL−1, respectively, for all analytes both in premortem and postmortem whole blood samples. A quadratic calibration model was used for the 12 quantitative analytes over the concentration range of 20–2000 ng mL−1, and the method was shown to be precise and accurate both in premortem and postmortem whole blood. The method was applied to the analysis of real cases and proved to be a valuable tool in forensic and clinical toxicology.


2021 ◽  
Vol 2 (1) ◽  
pp. 100311
Author(s):  
Daniella C. Terenzi ◽  
Ehab Bakbak ◽  
Justin Z. Trac ◽  
Mohammad Al-Omran ◽  
Adrian Quan ◽  
...  

Author(s):  
Polina A. Dyachenko Timoshina ◽  
Leonid E. Dolotov ◽  
Ekaterina N. Lazareva ◽  
Anastasiia A. Kozlova ◽  
Olga A. Inozemtseva ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document