scholarly journals Characteristics of Land–Atmosphere Interaction Parameters over the Tibetan Plateau

2011 ◽  
Vol 12 (4) ◽  
pp. 702-708 ◽  
Author(s):  
Shuzhou Wang ◽  
Yaoming Ma

Abstract In this study, eddy covariance flux data collected from three research stations on the Tibetan Plateau—Qomolangma for Atmospheric and Environmental Observation and Research, Nam Co for Multisphere Observation and Research, and Southeast Tibet Station for Alpine Environment Observation and Research, Chinese Academy of Sciences—are used to analyze the variation of momentum transfer coefficient (CD), heat transfer coefficient (CH), aerodynamic roughness length (z0m), thermal roughness length (z0h), and excess resistance to heat transfer (kB−1, where k is von Kármán’s constant and B−1 is a non-dimensional bulk parameter). The following results are found. The monthly average surface roughness, bulk transfer coefficient, and excess resistance to heat transfer at all three stations are obtained. The values of average heat bulk transfer coefficients are larger than those of average momentum bulk transfer coefficients at all three stations. The parameter kB−1 exhibits clear diurnal variations with lower values in the night and higher values in the daytime, especially in the afternoon. Negative values of kB−1 are often observed in the night for relatively smooth surfaces on the Tibetan Plateau, indicating that heat transfer efficiency may exceed that of momentum transfer.

Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
Jatuporn Kaew-On ◽  
Somchai Wongwises

The evaporation heat transfer coefficients and pressure drops of R-410A and R-134a flowing through a horizontal-aluminium rectangular multiport mini-channel having a hydraulic diameter of 3.48 mm are experimentally investigated. The test runs are done at refrigerant mass fluxes ranging between 200 and 400 kg/m2s. The heat fluxes are between 5 and 14.25 kW/m2, and refrigerant saturation temperatures are between 10 and 30 °C. The effects of the refrigerant vapour quality, mass flux, saturation temperature and imposed heat flux on the measured heat transfer coefficient and pressure drop are investigated. The experimental data show that in the same conditions, the heat transfer coefficients of R-410A are about 20–50% higher than those of R-134a, whereas the pressure drops of R-410A are around 50–100% lower than those of R-134a. The new correlations for the evaporation heat transfer coefficient and pressure drop of R-410A and R-134a in a multiport mini-channel are proposed for practical applications.


1993 ◽  
Vol 115 (4) ◽  
pp. 231-236 ◽  
Author(s):  
V. B. Sharma ◽  
S. C. Mullick

An approximate method for calculation of the hourly output of a solar still over a 24-hour cycle has been studied. The hourly performance of a solar still is predicted given the values of the insolation, ambient temperature, wind heat-transfer coefficient, water depth, and the heat-transfer coefficient through base and sides. The proposed method does not require graphical constructions and does not assume constant heat-transfer coefficients as in the previous methods. The possibility of using the values of the heat-transfer coefficients for the preceding time interval in the heat balance equations is examined. In fact, two variants of the basic method of calculation are examined. The hourly rate of evaporation is obtained. The results are compared to those obtained by numerical solution of the complete set of heat balance equations. The errors from the approximate method in prediction of the 24-hour output are within ±1.5 percent of the values from the numerical solution using the heat balance equations. The range of variables covered is 5 to 15 cms in water depth, 0 to 3 W/m2K in a heat-transfer coefficient through base and sides, and 5 to 40 W/m2K in a wind heat-transfer coefficient.


Author(s):  
Nirm V. Nirmalan ◽  
Ronald S. Bunker ◽  
Carl R. Hedlung

A new method has been developed and demonstrated for the non-destructive, quantitative assessment of internal heat transfer coefficient distributions of cooled metallic turbine airfoils. The technique employs the acquisition of full-surface external surface temperature data in response to a thermal transient induced by internal heating/cooling, in conjunction with knowledge of the part wall thickness and geometry, material properties, and internal fluid temperatures. An imaging Infrared camera system is used to record the complete time history of the external surface temperature response during a transient initiated by the introduction of a convecting fluid through the cooling circuit of the part. The transient data obtained is combined with the cooling fluid network model to provide the boundary conditions for a finite element model representing the complete part geometry. A simple 1D lumped thermal capacitance model for each local wall position is used to provide a first estimate of the internal surface heat transfer coefficient distribution. A 3D inverse transient conduction model of the part is then executed with updated internal heat transfer coefficients until convergence is reached with the experimentally measured external wall temperatures as a function of time. This new technique makes possible the accurate quantification of full-surface internal heat transfer coefficient distributions for prototype and production metallic airfoils in a totally non-destructive and non-intrusive manner. The technique is equally applicable to other material types and other cooled/heated components.


2017 ◽  
Vol 15 (3) ◽  
pp. 467
Author(s):  
Ravinder Kumar Sahdev ◽  
Mahesh Kumar ◽  
Ashwani Kumar Dhingra

In this paper, convective and evaporative heat transfer coefficients of the Indian groundnut were computed under indoor forced convection drying (IFCD) mode. The groundnuts were dried as a single thin layer with the help of a laboratory dryer till the optimum safe moisture storage level of 8 – 10%. The experimental data were used to determine the values of experimental constants C and n in the Nusselt number expression by a simple linear regression analysis and consequently, the convective heat transfer coefficient (CHTC) was determined. The values of CHTC were used to calculate the evaporative heat transfer coefficient (EHTC). The average values of CHTC and EHTC were found to be 2.48 W/m2 oC and 35.08 W/m2 oC, respectively. The experimental error in terms of percent uncertainty was also estimated. The experimental error in terms of percent uncertainty was found to be 42.55%. The error bars for convective and evaporative heat transfer coefficients are also shown for the groundnut drying under IFCD condition.


2000 ◽  
Author(s):  
M. Kumagai ◽  
R. S. Amano ◽  
M. K. Jensen

Abstract A numerical and experimental investigation on cooling of a solid surface was performed by studying the behavior of an impinging jet onto a fixed flat target. The local heat transfer coefficient distributions on a plate with a constant heat flux were computationally investigated with a normally impinging axisymmetric jet for nozzle diameter of 4.6mm at H/d = 4 and 10, with the Reynolds numbers of 10,000 and 40,000. The two-dimensional cylindrical Navier-Stokes equations were solved using a two-equation k-ε turbulence model. The finite-volume differencing scheme was used to solve the thermal and flow fields. The predicted heat transfer coefficients were compared with experimental measurements. A universal function based on the wave equation was developed and applied to the heat transfer model to improve calculated local heat transfer coefficients for short nozzle-to-plate distance (H/d = 4). The differences between H/d = 4 and 10 due to the correlation among heat transfer coefficient, kinetic energy and pressure were investigated for the impingement region. Predictions by the present model show good agreement with the experimental data.


2000 ◽  
Author(s):  
Edward V. McAssey ◽  
Jinfeng Wu ◽  
Thomas Dougherty ◽  
Bao Wen Yang

Abstract Data are presented for sub-cooled boiling of water in the range of two to four atmospheres. The results show that the sharp increase in heat transfer coefficient associated with nucleate boiling occurs at wall superheats of 20 °C to 30 °C. Comparisons between experimental and predicted heat transfer coefficients are also presented. The two prediction methods examined are the Chen correlation and the Kandlikar correlation.


2020 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Iskandar Waini ◽  
Anuar Ishak ◽  
Ioan Pop

Purpose This paper aims to examine the effect of Dufour and Soret diffusions on Al2O3-water nanofluid flow over a moving thin needle by using the Tiwari and Das model. Design/methodology/approach The governing equations are reduced to the similarity equations using similarity transformations. The resulting equations are programmed in Matlab software through the bvp4c solver to obtain their solutions. The features of the skin friction, heat transfer and mass transfer coefficients, as well as the velocity, temperature and concentration profiles for different values of the physical parameters, are analysed and discussed. Findings The non-uniqueness of the solutions is observed for a certain range of the physical parameters. The authors also notice that the bifurcation of the solutions occurs in which the needle moves toward the origin (λ < 0). It is discovered that the first branch solutions of the skin friction coefficient and the heat transfer coefficients increase, but the mass transfer coefficient decreases in the presence of nanoparticle. Additionally, the simultaneous effect of Dufour and Soret diffusions tends to enhance the heat transfer coefficient; however, dual behaviours are observed for the mass transfer coefficient. Further analysis shows that between the two solutions, only one of them is stable and thus physically reliable in the long run. Originality/value The problem of Al2O3-water nanofluid flow over a moving thin needle with Dufour and Soret effects are the important originality of the present study. Besides, the temporal stability of the dual solutions is examined for time.


Metals ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 1367
Author(s):  
Nino Wolff ◽  
Golo Zimmermann ◽  
Uwe Vroomen ◽  
Andreas Bührig-Polaczek

Local heat transfer in gravity die casting is of great importance for precision in terms of distortion, mechanical properties, and the quality of the castings due to its effect on solidification. Depending on contact conditions such as liquid melt to solid mold, a gap between mold and component, or contact pressure between casting and mold as a result of shrinkage, there are very large differences in heat transfer. The influences of mold material, mold coating and its influence of aging, mold temperature control, and layout on the heat transfer coefficient (HTC) were investigated experimentally for different contact cases. The experiments were carried out on a rotationally symmetrical experimental setup with modular exchangeable die inserts and cores using an AlSi7Mg0.3 alloy. From the results of the individual test series, the quantitative shares of the above-mentioned influencing variables in the respective effective heat transfer coefficients were determined by means of analysis of variance. From this, the parameters having the most significant influence on the local heat balance were derived.


Sign in / Sign up

Export Citation Format

Share Document