Present Audiologic Status of Subjects Implanted with Auditory Prostheses

1977 ◽  
Vol 86 (3_suppl) ◽  
pp. 40-48 ◽  
Author(s):  
N. T. Hopkinson ◽  
R. C. Bilger ◽  
F. O. Black

Audiological testing indicated that all of the subjects had profound sensorineural hearing losses. In 12 of the 13 subjects, this profound hearing loss was bilateral. The 13th subject, however, had useable hearing in his unimplanted ear. Tympanometric testing gave no evidence that implant surgery had disrupted middle ear function.

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 946
Author(s):  
Dong Ho Shin

This report describes the design of a new piezoelectric transducer for round window (RW)-driven middle ear implants. The transducer consists of a piezoelectric element, gold-coated copper bellows, silicone elastomer (polydimethylsiloxane, PDMS), metal cylinder (tungsten), and titanium housing. The piezoelectric element is fixed to the titanium housing and mechanical resonance is generated by the interaction of the bellows, PDMS, and tungsten cylinder. The dimensions of PDMS and the tungsten cylinder with output characteristics suitable for compensation of sensorineural hearing loss were derived by mechanical vibrational analysis (equivalent mechanical model and finite element analysis (FEA)). Based on the results of FEA, the RW piezoelectric transducer was implemented, and bench tests were performed under no-load conditions to confirm the output characteristics. The transducer generates an average displacement of 219.6 nm in the flat band (0.1–1 kHz); the resonance frequency is 2.3 kHz. To evaluate the output characteristics, the response was compared to that of an earlier transducer. When driven by the same voltage (6 Vp), the flat band displacement averaged 30 nm larger than that of the other transducer, and no anti-resonance was noted. Therefore, we expect that the new transducer can serve as an output device for hearing aids, and that it will improve speech recognition and treat high-frequency sensorineural hearing loss more effectively.


2008 ◽  
Vol 19 (03) ◽  
pp. 267-274 ◽  
Author(s):  
David B. Hawkins

A case report is presented of a 62-year-old software product manager who had normal hearing in one ear and a congenital profound hearing loss in the other ear and then sustained a sudden sensorineural hearing loss in the only hearing ear. The approach to amplification decisions, cochlear implant evaluation, and rehabilitation options are discussed. Providing aural rehabilitation and continually updating and providing new amplification options and accessories are described. Se presenta un reporte de caso de un gerente de productos de software de 62 años de edad quien tenía audición normal en un oído y un sordera congénita profunda en el otro, y quién súbitamente sufrió una sordera sensorineural súbita en el único oído con audición. Se discute el enfoque de decisiones de amplificación, la evaluación para implante coclear, y las opciones de rehabilitación. Se describen las pautas para proveer rehabilitación aural y para actualizar continuamente y aportar nuevas opciones de amplificación.


2017 ◽  
Vol 138 (1) ◽  
pp. 31-35 ◽  
Author(s):  
Maurizio Barbara ◽  
Luigi Volpini ◽  
Chiara Filippi ◽  
Francesca Atturo ◽  
Simonetta Monini

1998 ◽  
Vol 107 (10) ◽  
pp. 876-884 ◽  
Author(s):  
Yoshiharu Ohno ◽  
Yoshihiro Ohashi ◽  
Hideki Okamoto ◽  
Yoshikazu Sugiura ◽  
Yoshiaki Nakai

The effect of platelet activating factor (PAF) was studied to elucidate its role in the pathogenesis of otitis media and sensorineural hearing loss. The PAF alone did not induce a reduction of ciliary activity of the cultured middle ear mucosa. However, a dose-dependent decrease in ciliary activity was observed in the presence of the medium containing both PAF and macrophages. Intravenous injection of PAF did not induce dysfunction of the mucociliary system or morphologic changes of epithelium in the tubotympanum, but cytoplasmic vacuolization and ballooning were observed in the inner ear within 1 hour after injection of PAF. In contrast, intratympanic injection of PAF induced mucociliary dysfunction and some pathologic changes in the tubotympanum. Intratympanic inoculation of PAF induced no pathologic findings in the inner ear. These results suggest that PAF is at least partially involved in the pathogenesis of certain middle ear diseases such as otitis media with effusion. Additionally, PAF might be involved in the pathogenesis of some types of unexplained sensorineural hearing loss.


PEDIATRICS ◽  
1987 ◽  
Vol 80 (4) ◽  
pp. 524-528
Author(s):  
Lorne S. Parnes ◽  
Brian F. McCabe

This study underscores the importance of considering a perilymph fistula, an abnormal communication between the inner and middle ear, in any child with a progressive sensorineural hearing loss. A concomitant complaint of intermittent dizziness or observed spells of imbalance (56%) is another indication of the disease. Six of 16 patients (37.5%) with proven fistulas were less than 2 years of age at the onset of symptoms. Unless the fistula is identified and repaired by grafting, the ear may become totally deaf. This would be disastrous in the presence of bilateral fistulas, which occur commonly in children (56% of patients had symptoms of bilateral disease). Our experience in recognizing and treating fistulas and thereby saving and restoring hearing is described.


2021 ◽  
Vol 104 (2) ◽  
pp. 260-263

Background: Bacterial meningitis is one of the major factors in the etiology of acquired sensorineural hearing loss in children and adults. Cochlear implantation in these patients is challenging because of inner ear ossification and fibrosis, and this procedure sometimes achieves poorer outcomes in this scenario than with other causes of sensorineural hearing loss. There has been little research into the factors affecting the outcomes of this procedure. Objective: To evaluate the outcomes of cochlear implantation in patients with postmeningitis profound sensorineural hearing loss and to evaluate the factors that affect the results. Materials and Methods: A retrospective review was conducted of thirty patients who were diagnosed with post meningitis profound hearing loss and underwent cochlear implantation at Rajavithi Hospital between 2001 and 2016. Preoperative language status, duration of deafness, preoperative imaging, and degree of electrode insertion were recorded. Categories of auditory performance-II test (CAP-II) was evaluated in all cases, one year postoperative. Results: Thirty postmeningitis deafness patients underwent cochlear implantation. The median age at diagnosis of meningitis and age at implantation were 41 years (range 1 to 75) and 49.50 years (range 3 to 75), respectively. The median duration of deafness was 12 months (range 4 to 300), and the overall mean CAP-II at one year after surgery was 5.47±2.21. The postlinguistic group had a significantly higher CAP-II score than the prelinguistic one (p=0.006). Electrodes were successfully totally inserted in 19 patients (63.3%) and partially inserted in 11 (36.7%). The average CAP-II score in the group with fully-inserted electrodes was significantly higher than in the group with partially-inserted electrodes (p=0.045). There was no correlation between CAP-II score and age at meningitis diagnosis (p=0.069), age at time of surgery (p=0.105), duration of deafness (p=0.506), or preoperative CT (p=0.228) or MRI abnormality (p=0.078). Conclusion: Cochlear implantation in patients with postmeningitis profound hearing loss had high success rates and favorable outcomes. Preoperative language status and degree of electrode insertion were factors that affected auditory performance results. Keywords: Cochlear implantation, Postmeningitis hearing loss, Sensorineural hearing loss, Meningitis, Rajavithi Hospital


1997 ◽  
Vol 76 (5) ◽  
pp. 333-341 ◽  
Author(s):  
Anthony J. Maniglia ◽  
Wen H. Ko ◽  
Steven L. Garverick ◽  
Hassan Abbass ◽  
Michael Kane ◽  
...  

A semi-implantable middle ear electromagnetic hearing device (SIMEHD) is proposed for limited clinical trial in adult patients to evaluate the implantable hearing device for moderate to severe sensorineural hearing loss. Food and Drug Administration (FDA) investigational device exemption (IDE) approval has been granted (May 1996) for clinical trials. The implant unit has been evaluated acutely and chronically in animals (cats) with excellent results. Five cats undergoing chronic implantation were allowed to survive an average of 9.6 months, showing that the SIMEHD is biocompatible, functional and without untoward complications. All implant units recovered from the cats were functional, except for wire breakage of the internal antenna. A new antenna was redesigned for human implantation. The SIMEHD system consists of an external and internal unit. The external unit consists of a microphone, audio amplifier, modulator, radio frequency (RF) amplifier, antenna and battery. The internal unit is composed of a receiving antenna, hybrid electronic circuit, air core driving coil, and a target magnet cemented to the incus. All materials in contact with the body are biocompatible and expected to survive indefinitely. The implant unit is miniaturized and manufactured with existing fabrication technology by our industrial collaborator, Wilson Greatbatch, Ltd. The specific aims and major tasks of the proposed research are: a) to evaluate reliability, safety and efficacy of the SIMEHD system in a selected group of patients diagnosed with sensorineural hearing loss, due mainly to presbycusis or aging of the inner ear; and b) to obtain objective and subjective evaluation of audiologic and psychoacoustic performance as compared to the acoustic hearing aid. This paper describes the design, illustrates the actual device (newest prototype) and details the technique for surgical implantation in the attic and mastoid antrum in humans.