A Comprehensive Software Simulator for Teaching Power Distribution Systems

1993 ◽  
Vol 30 (3) ◽  
pp. 254-268 ◽  
Author(s):  
C.Y. Teo

A comprehensive software simulator for teaching power distribution systems An innovative distribution system simulator integrating load flow, fault current calculation and modelling of overcurrent relays and breaker operation is described. Appropriate sets of scenarios are generated for different levels of exercise and all actions taken by the student are logged, automatically evaluated and awarded a grade.

2018 ◽  
Vol 8 (5) ◽  
pp. 3398-3404 ◽  
Author(s):  
A. Al-Sakkaf ◽  
M. AlMuhaini

Power flow is one of the essential studies in power system operation and planning. All steady-state parameters for power distribution systems, such as bus voltage magnitudes, angles, power flows, and power losses, can be calculated by conducting power flow analysis. Distribution system features differ from those of transmission system, rendering conventional load flow algorithms inapplicable. In this paper, three distribution power flow techniques are presented and tested to evaluate their performance when applied to a networked distribution system including distributed generation (DG). These are the distribution load flow (DLF) matrix, the enhanced Newton Raphson (ENR), and the robust decoupled (RD) method. IEEE 33-bus system is adopted for implementing the above methods. Radial and weakly meshed configurations are applied to the tested system with DG inclusion to investigate their influence on the power flow study findings.


2012 ◽  
Vol 622-623 ◽  
pp. 1882-1886
Author(s):  
Hadi Zayandehroodi ◽  
Azah Mohamed ◽  
Hussain Shareef ◽  
Masoud Farhoodnea ◽  
Marjan Mohammadjafari

The presence of renewable distributed generator (RDG) in a distribution system will have unfavorable impact on the operating system because the distribution system is no longer radial in nature and is not supplied by a single main power source. With RDGs in a distribution network, it brings about a change in the fault current level of the system and causes many problems in the protection system, such as false tripping of protective devices, protection blinding, an increase and decrease in short-circuit levels. This paper presents the effect of RDGs on the fault current level of the system. The operating protection issues particularly in cases where RDGs are added to a LV distribution feeder are also discussed.


2019 ◽  
Vol 4 (1) ◽  
pp. 238
Author(s):  
Nahdia Rupawanti BR

Electric power distribution systems that use air cables or ground cables often experience various disturbances. Interference that often occurs is symmetry or non-symmetric interference which can be a short relationship between one phase to the ground, between phases or the breakdown of one or more. To find out the magnitude of the interference current, an analysis of the transformer distribution system is needed to determine the disturbances that will occur.The transformer which is the main equipment in a GI must be considered in order to get the proper current circuit and security. Designing the right transformer setting is an effort to protect equipment, systems and consumer needs from disturbances that may occur in the distribution system. The calculation of the fault current and the magnitude of the nominal current of the transformer will be used as an important reference in determining the transformer settings in the distribution of voltage to consumers.From the results of these calculations it can be concluded that the performance time of feeder relays is slower than the time of relay in the event. The data in the field is still in the right condition (the difference is not too far), so that the overall OCR-GFR setting in the field is still in good condition.


Energies ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4810 ◽  
Author(s):  
Sang-Jae Choi ◽  
Sung-Hun Lim

Recently, studies on connecting distributed generation (DG) to power distribution systems through DC links have been actively conducted. When a fault in feeder of this power distribution system occurs, a voltage dip can happen in the grid. In order to prevent voltage dips, there are several solutions such as the application of a superconducting fault current limiter (SFCL). If a SFCL with a larger impedance is applied, the voltage dip of the grid is effectively prevented. However, this action can bring about the malfunction or the delayed operation of the over-current relay (OCR) due to the decreased fault current, which causes another problem of protection coordination between the protective relays. On the other hand, if the impedance of the SFCL is too low, excessive reactive power is supplied by the fault ride-through (FRT) regulation and the active power is reduced. This causes an active power imbalance on the DC link and increases the DC link’s voltage. As previous solutions to prevent the rise of DC links’ voltage, the deloading method and the application of a chopper resistor have been suggested. In this paper, a technique called active power tracking control (APTC), was proposed to suppress the rise of DC links’ voltage. Case studies considering the impedance of SFCL in the constructed power distribution system were carried out, and the rise of DC links’ voltage could be effectively suppressed without any significant delay in the operation of the OCR. This study is expected to solve both the voltage dip of the grid and the rise of DC links’ voltage when distributed generation is connected to a grid.


Mathematics ◽  
2018 ◽  
Vol 6 (9) ◽  
pp. 158
Author(s):  
Farzaneh Pourahmadi ◽  
Payman Dehghanian

Allocation of the power losses to distributed generators and consumers has been a challenging concern for decades in restructured power systems. This paper proposes a promising approach for loss allocation in power distribution systems based on a cooperative concept of game-theory, named Shapley Value allocation. The proposed solution is a generic approach, applicable to both radial and meshed distribution systems as well as those with high penetration of renewables and DG units. With several different methods for distribution system loss allocation, the suggested method has been shown to be a straight-forward and efficient criterion for performance comparisons. The suggested loss allocation approach is numerically investigated, the results of which are presented for two distribution systems and its performance is compared with those obtained by other methodologies.


Symmetry ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 775
Author(s):  
Sheng-Yu Tseng ◽  
Jun-Hao Fan

Due to the advantages of power supply systems using the DC distribution method, such as a conversion efficiency increase of about 5–10%, a cost reduction of about 15–20%, etc., AC power distribution systems will be replaced by DC power distribution systems in the future. This paper adopts different converters to generate DC distribution system: DC/DC converter with PV arrays, power factor correction with utility line and full-bridge converter with multiple input sources. With this approach, the proposed full-bridge converter with soft-switching features for generating a desired voltage level in order to transfer energy to the proposed DC distribution system. In addition, the proposed soft-switching full-bridge converter is used to generate the DC voltage and is applied to balance power between the PV arrays and the utility line. Due to soft-switching features, the proposed full-bridge converter can be operated with zero-voltage switching (ZVS) at the turn-on transition to increase conversion efficiency. Finally, a prototype of the proposed full-bridge converter under an input voltage of DC 48 V, an output voltage of 24 V, a maximum output current of 21 A and a maximum output power of 500 W was implemented to prove its feasibility. From experimental results, it can be found that its maximum conversion efficiency is 92% under 50% of full-load conditions. It was shown to be suitable for DC distribution applications.


DYNA ◽  
2015 ◽  
Vol 82 (192) ◽  
pp. 141-149 ◽  
Author(s):  
Andres Felipe Panesso-Hernández ◽  
Juan Mora-Flórez ◽  
Sandra Pérez-Londoño

<p>The impedance-based approaches for fault location in power distribution systems determine a faulted line section. Next, these require of the estimation of the voltages and currents at one or both section line ends to exactly determine the fault location. It is a challenge because in most of the power distribution systems, measurements are only available at the main substation.  This document presents a modeling proposal of the power distribution system and an easy implementation method to estimate the voltages and currents at the faulted line section, using the measurements at the main substation, the line, load, transformer parameters and other serial and shunt connected devices and the power system topology. The approach here proposed is tested using a fault locator based on superimposed components, where the distance estimation error is lower than 1.5% in all of the cases. </p>


Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 334
Author(s):  
Esteban Pulido ◽  
Luis Morán ◽  
Felipe Villarroel ◽  
José Silva

In this paper, a new concept of short-circuit current (SCC) reduction for power distribution systems is presented and analyzed. Conventional fault current limiters (FCLs) are connected in series with a circuit breaker (CB) that is required to limit the short-circuit current. Instead, the proposed scheme consisted of the parallel connection of a current-controlled power converter to the same bus intended to reduce the amplitude of the short-circuit current. This power converter was controlled to absorb a percentage of the short-circuit current from the bus to reduce the amplitude of the short-circuit current. The proposed active short-circuit current reduction scheme was implemented with a cascaded H-bridge power converter and tested by simulation in a 13.2 kV industrial power distribution system for three-phase faults, showing the effectiveness of the short-circuit current attenuation in reducing the maximum current requirement in all circuit breakers connected to the same bus. The paper also presents the design characteristics of the power converter and its associated control scheme.


2019 ◽  
Vol 217 ◽  
pp. 01020 ◽  
Author(s):  
Margarita Chulyukova ◽  
Nikolai Voropai

The paper considers the possibilities of increasing the flexibility of power distribution systems by real-time load management. The principles of the implementation of special automatic systems for this purpose are proposed. These systems enable some loads of specific consumers of the power distribution system switched to islanded operation to “shift” from the daily maximum to the minimum, which makes some generators available to connect certain essential consumers disconnected earlier by under-frequency load shedding system to the power system. The approach under consideration is illustrated by a power system with distributed generation.


Sign in / Sign up

Export Citation Format

Share Document