scholarly journals A Game-Theoretic Loss Allocation Approach in Power Distribution Systems with High Penetration of Distributed Generations

Mathematics ◽  
2018 ◽  
Vol 6 (9) ◽  
pp. 158
Author(s):  
Farzaneh Pourahmadi ◽  
Payman Dehghanian

Allocation of the power losses to distributed generators and consumers has been a challenging concern for decades in restructured power systems. This paper proposes a promising approach for loss allocation in power distribution systems based on a cooperative concept of game-theory, named Shapley Value allocation. The proposed solution is a generic approach, applicable to both radial and meshed distribution systems as well as those with high penetration of renewables and DG units. With several different methods for distribution system loss allocation, the suggested method has been shown to be a straight-forward and efficient criterion for performance comparisons. The suggested loss allocation approach is numerically investigated, the results of which are presented for two distribution systems and its performance is compared with those obtained by other methodologies.

Author(s):  
Reza Tajik

Nowadays, the utilization of renewable energy resources in distribution systems (DSs) has been rapidly increased. Since distribution generation (DG) use renewable resources (i.e., biomass, wind and solar) are emerging as proper solutions for electricity generation. Regarding the tremendous deployment of DG, common distribution networks are undergoing a transition to DSs, and the common planning methods have become traditional in the high penetration level. Indeed, in conformity with the voltage violation challenge of these resources, this problem must be dealt with too. So, due to the high penetration of DG resources and nonlinear nature of most industrial loads, the planning of DG installation has become an important issue in power systems. The goal of this paper is to determine the planning of DG in distribution systems through smart grid to minimize losses and control grid factors. In this regard, the present work intending to propose a suitable method for the planning of DSs, the key properties of DS planning problem are evaluated from the various aspects, such as the allocation of DGs, and planning, and high-level uncertainties. Also depending on these analyses, this universal literature review addressed the updated study associated with DS planning. In this work, an operational design has been prepared for a higher performance of the power distribution system in the presence of DG. Artificial neural network (ANN) has been used as a method for voltage monitoring and generation output optimization. The findings of the study show that the proposed method can be utilized as a technique to improve the process of the distribution system under various penetration levels and in the presence of DG. Also, the findings revealed that the optimal use of ANN method leads to more controllable and apparent DS.


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 199
Author(s):  
Chengwei Lei ◽  
Weisong Tian

Fused contactors and thermal magnetic circuit breakers are commonly applied protective devices in power distribution systems to protect the circuits when short-circuit faults occur. A power distribution system may contain various makes and models of protective devices, as a result, customizable simulation models for protective devices are demanded to effectively conduct system-level reliable analyses. To build the models, thermal energy-based data analysis methodologies are first applied to the protective devices’ physical properties, based on the manufacturer’s time/current data sheet. The models are further enhanced by integrating probability tools to simulate uncertainties in real-world application facts, for example, fortuity, variance, and failure rate. The customizable models are expected to aid the system-level reliability analysis, especially for the microgrid power systems.


2015 ◽  
Vol 16 (2) ◽  
pp. 232
Author(s):  
Raja Masood Larik ◽  
Mohd Wazir Mustafa

<span style="line-height: 107%; font-family: 'Arial',sans-serif; font-size: 9pt; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">Recently, the debate has been going on about the role of power plus distribution systems, its technologies for future smart grids in power systems. The emerging of new technologies in smart grid and power distribution systems provide a significant change in terms of reduction the commercial and technical losses, improve the rationalization of electricity tariff. The new technologies in smart grid systems have different capabilities to increase the technological efficiency in power distribution systems. These new technologies are the foreseeable solution to address the power system issues. This paper gives a brief detail of new technologies in smart grid systems for its power distribution systems, benefits and recent challenges. The paper provides a brief detail for new researchers and engineers about new technologies in smart grid systems and how to change traditional distribution systems into new smart systems.</span>


2012 ◽  
Vol 622-623 ◽  
pp. 1882-1886
Author(s):  
Hadi Zayandehroodi ◽  
Azah Mohamed ◽  
Hussain Shareef ◽  
Masoud Farhoodnea ◽  
Marjan Mohammadjafari

The presence of renewable distributed generator (RDG) in a distribution system will have unfavorable impact on the operating system because the distribution system is no longer radial in nature and is not supplied by a single main power source. With RDGs in a distribution network, it brings about a change in the fault current level of the system and causes many problems in the protection system, such as false tripping of protective devices, protection blinding, an increase and decrease in short-circuit levels. This paper presents the effect of RDGs on the fault current level of the system. The operating protection issues particularly in cases where RDGs are added to a LV distribution feeder are also discussed.


Author(s):  
Oladimeji Joseph Ayamolowo ◽  
Ayodeji Olalekan Salau

Energy audit and reliability assessment of distribution systems are important to keep track of power system's performance. It helps to minimize power interruptions to customers, boost industrialization, research, and economic development in any country or community. This chapter presents the reliability assessment of power distribution systems in Afe Babalola University, Ado-Ekiti, Nigeria. A critical assessment of the power distribution process was carried out with data obtained from the central Substation, taking into account various reliability indices. Furthermore, the load consumption of each substation was considered for the period of January to December, 2017. The results obtained show that the University attained a power availability (ASAI) of 0.99984 because of the presence of strategically placed distributed generators (DGs). The reliability assessment revealed SAIDI as 1.4347 hours/customer year, CAIDI as 0.6620 hours/customer interruption, ASUI as 0.00016, and SAIFI as 2.16712 failures/ customer year.


Author(s):  
Wen Fan ◽  
Yuan Liao ◽  
Ning kang

AbstractAccurate fault location in distribution systems greatly shortens maintenance time and improves reliability. This paper presents novel methods to pinpoint fault location and identify possible bad measurements for enhanced accuracy. It is assumed that network parameters and topology of the distribution network are available. The methods are applicable to a single fault as well as simultaneous faults and are applicable to both balanced and unbalanced networks. The methods utilize synchronized voltage and current phasor measurements to locate the fault. The methods are validated by simulation studies using the modified IEEE 34-Node Test System. Case studies have demonstrated that the methods are suitable for distribution systems with high penetration of distributed generations.


Symmetry ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 775
Author(s):  
Sheng-Yu Tseng ◽  
Jun-Hao Fan

Due to the advantages of power supply systems using the DC distribution method, such as a conversion efficiency increase of about 5–10%, a cost reduction of about 15–20%, etc., AC power distribution systems will be replaced by DC power distribution systems in the future. This paper adopts different converters to generate DC distribution system: DC/DC converter with PV arrays, power factor correction with utility line and full-bridge converter with multiple input sources. With this approach, the proposed full-bridge converter with soft-switching features for generating a desired voltage level in order to transfer energy to the proposed DC distribution system. In addition, the proposed soft-switching full-bridge converter is used to generate the DC voltage and is applied to balance power between the PV arrays and the utility line. Due to soft-switching features, the proposed full-bridge converter can be operated with zero-voltage switching (ZVS) at the turn-on transition to increase conversion efficiency. Finally, a prototype of the proposed full-bridge converter under an input voltage of DC 48 V, an output voltage of 24 V, a maximum output current of 21 A and a maximum output power of 500 W was implemented to prove its feasibility. From experimental results, it can be found that its maximum conversion efficiency is 92% under 50% of full-load conditions. It was shown to be suitable for DC distribution applications.


DYNA ◽  
2015 ◽  
Vol 82 (192) ◽  
pp. 141-149 ◽  
Author(s):  
Andres Felipe Panesso-Hernández ◽  
Juan Mora-Flórez ◽  
Sandra Pérez-Londoño

<p>The impedance-based approaches for fault location in power distribution systems determine a faulted line section. Next, these require of the estimation of the voltages and currents at one or both section line ends to exactly determine the fault location. It is a challenge because in most of the power distribution systems, measurements are only available at the main substation.  This document presents a modeling proposal of the power distribution system and an easy implementation method to estimate the voltages and currents at the faulted line section, using the measurements at the main substation, the line, load, transformer parameters and other serial and shunt connected devices and the power system topology. The approach here proposed is tested using a fault locator based on superimposed components, where the distance estimation error is lower than 1.5% in all of the cases. </p>


Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 334
Author(s):  
Esteban Pulido ◽  
Luis Morán ◽  
Felipe Villarroel ◽  
José Silva

In this paper, a new concept of short-circuit current (SCC) reduction for power distribution systems is presented and analyzed. Conventional fault current limiters (FCLs) are connected in series with a circuit breaker (CB) that is required to limit the short-circuit current. Instead, the proposed scheme consisted of the parallel connection of a current-controlled power converter to the same bus intended to reduce the amplitude of the short-circuit current. This power converter was controlled to absorb a percentage of the short-circuit current from the bus to reduce the amplitude of the short-circuit current. The proposed active short-circuit current reduction scheme was implemented with a cascaded H-bridge power converter and tested by simulation in a 13.2 kV industrial power distribution system for three-phase faults, showing the effectiveness of the short-circuit current attenuation in reducing the maximum current requirement in all circuit breakers connected to the same bus. The paper also presents the design characteristics of the power converter and its associated control scheme.


2019 ◽  
Vol 217 ◽  
pp. 01020 ◽  
Author(s):  
Margarita Chulyukova ◽  
Nikolai Voropai

The paper considers the possibilities of increasing the flexibility of power distribution systems by real-time load management. The principles of the implementation of special automatic systems for this purpose are proposed. These systems enable some loads of specific consumers of the power distribution system switched to islanded operation to “shift” from the daily maximum to the minimum, which makes some generators available to connect certain essential consumers disconnected earlier by under-frequency load shedding system to the power system. The approach under consideration is illustrated by a power system with distributed generation.


Sign in / Sign up

Export Citation Format

Share Document