Jurnal Elektro
Latest Publications


TOTAL DOCUMENTS

26
(FIVE YEARS 0)

H-INDEX

1
(FIVE YEARS 0)

Published By Universitas Islam Lamongan

2502-0986

2019 ◽  
Vol 4 (1) ◽  
pp. 247
Author(s):  
Zainal Abidin

Alternative methods and modeling control of motor speed with the voltage regulation method currently used, namely the constant Volt / Hertz method with Pulse With Modulation (PWM) with several advantages and disadvantages and showing possible advantages and disadvantages to achieve the new method compared to the used today.The characteristics of the use of PWM can be studied together with the use of Matlab / Simulink modeling.


2019 ◽  
Vol 4 (1) ◽  
pp. 253
Author(s):  
Mahrus Ali ◽  
Muhlasin Muhlasin

Permanent Magnet Syschronous Machine (PMSM) has low torque in a number of specific applications, so a good control model is needed. PMSM uses the principle of faraday experiments by turning a magnet in a coil by utilizing another energy source ... When a magnet moves in a coil or vice versa. Turning the engine will change the magnetic force flux in the coil and penetrate perpendicular to the coil so that there is a potential difference between the ends of the coil. That is due to changes in magnetic flux. To get the best control method, a comparison of several speed control models is needed. In this study comparing PMSM speed control without controller, using PID controller, using FLC controller, and using ANFIS controller. From the simulation results show that the best model on ANFIS controller, which is closest to the Speed reff (300 rpm) is ANFIS obtained the round profile with the smallest undershot of 300,015 rpm at t = 0.0055 seconds and steady state at 300.02 rpm at 0.004 seconds, obtained output current profile best on FLC = 3.39 A, while at ANFIS = 3.38 A, the best torque profile (the smallest overshot) is obtained on the ANFIS controller of 0.28 pu, the best voltage profile (most continuous) on the ANFIS controller is 300.03. The results of this study will be continued with the use of other artificial intelligence.


2019 ◽  
Vol 4 (1) ◽  
pp. 228
Author(s):  
Affan Bachri

The process of firing is always unpredictable and predicted in advance. When it comes, what causes it, the level of coverage and how much impact it causes, are things that cannot be predicted by human capabilities. The design of a fire safety system that aims to improve the safety and comfort of occupants in the building. The analysis carried out is to measure and record temperature and conduct a series of several experiments. Temperature is equipped with Celsius (C) units and smoke uses PPM units (parts per million). By working, the smoke sensor and temperature will detect itself and work properly. And this is to avoid any errors caused by rising temperatures due to sunlight or smoke from cigarettes. If the LM35 temperature sensor reaches 40 C then the temperature will detect and the buzzer will sound the LED will be wrong and the LCD 2x16 will display "CAUTION THERE'S ASAP". If Smoke reaches from 600 upwards the smoke sensor will detect and the buzzer will sound, the LED light will light up then on LCD 2x16 will display "CAUTION THERE IS FIRE"


2019 ◽  
Vol 4 (1) ◽  
pp. 234
Author(s):  
Arief Budi Laksono

Along with the development of technology about audio soundsystems, innovations and new designs about audio are very many, music is an entertainment that is almost every day encountered by people today, Amplifier products that are commonly marketed (finished products) are still very dominated by the outside market country. GB Power Amplifier class (Ground Bridge) is one type of power amplifier that requires a high input voltage in the audio world, the use of a combination of suitable transformers and with the output voltage transformer that is able to meet the required power capacity for the amplifier without having to search for transformer with a high output specification. So a good component selection can make the power amplifier's performance to the maximum.


2019 ◽  
Vol 4 (1) ◽  
pp. 244
Author(s):  
Ulul Ilmi ◽  
Zainal Abidin

The progress of power electronics application technology, harmonic pollution in the electrical power system network is increasing seriously, having a serious impact on the energy supply network and equipment. In this discussion, the author studied harmonic characteristics, analysis of harmonic detection methods using wavelet algorithms with Matlab. The results of the simulation show that wavelet transforms can compose harmonic components that are settled in the system according to their needs.


2019 ◽  
Vol 4 (1) ◽  
pp. 238
Author(s):  
Nahdia Rupawanti BR

Electric power distribution systems that use air cables or ground cables often experience various disturbances. Interference that often occurs is symmetry or non-symmetric interference which can be a short relationship between one phase to the ground, between phases or the breakdown of one or more. To find out the magnitude of the interference current, an analysis of the transformer distribution system is needed to determine the disturbances that will occur.The transformer which is the main equipment in a GI must be considered in order to get the proper current circuit and security. Designing the right transformer setting is an effort to protect equipment, systems and consumer needs from disturbances that may occur in the distribution system. The calculation of the fault current and the magnitude of the nominal current of the transformer will be used as an important reference in determining the transformer settings in the distribution of voltage to consumers.From the results of these calculations it can be concluded that the performance time of feeder relays is slower than the time of relay in the event. The data in the field is still in the right condition (the difference is not too far), so that the overall OCR-GFR setting in the field is still in good condition.


2018 ◽  
Vol 3 (1) ◽  
pp. 16
Author(s):  
Suherman Suherman ◽  
Abd Rabi’ ◽  
Anggraini Puspita Sari

Berkembangnya era dan teknologi khususnya di bidang telekomunikasi sangat pesat, kebutuhan akan media telekomunikasi seperti penyiaran video secara real time merupakan prioritas utama dalam proses belajar mengajar, pengumuman berita dan sebagainya, komunikasi nirkabel yang efisien dan menghemat waktu. dalam penggunaannya Penelitian ini menggunakan kamera pada smartphone sebagai media input data yang dapat digunakan untuk pengguna dan menggunakan wifi (wireless Fidelity) sebagai komunikasi nirkabel, media transfer dan data trasmisi, dan penggunaan pada notebook sebagai media pengolahan data berupa video yang akan ditampilkan. pada monitor secara real time sebagai media output data yang telah di input oleh pengguna melalui smartphone kamera dalam bentuk video dengan berbagai format resolusi video mulai dari 480, 680 dan 720, dan hasil test data keluaran berupa video yang dengan menggunakan variabel delay, throughput dan packet loss, hasil dari pengujian variabel dengan menggunakan format video 480, 680 dan 720 menghasilkan rata-rata delay tercepat adalah 0.003738977 ms dan terlama adalah 0.00529923 ms, pada troughput tertinggi menghasilkan rata-rata 1.179 Mbps dan terendah 0.128 Mbps, pada packet loss tertinggi 17.6 % dan terendah 6.54 %.


2018 ◽  
Vol 3 (1) ◽  
pp. 5
Author(s):  
Nahdia Rupawanti BR

Transformer has an important role in the provision of electrical energy in power systems, especially for electrical distribution. Transformer change electrical energy into electrical energy in certain capacity has function and characteristics. As one of electrical machine, transformer has loss load, capacity and efficiency. Multisim 12.0 simulation appearance the transformer can be presented.


2018 ◽  
Vol 3 (1) ◽  
pp. 24
Author(s):  
Ahmad Syaifuddin F ◽  
Arief Budi Laksono ◽  
Suharijanto Suharijanto

Distribution system is divided into primary and secondary distribution networks. The primary distribution network is the network of the substation to the distribution, while the secondary distribution is the channel network from the substation transformer is distributed to the consumer or the load. Primary distribution network is better known as medium voltage network (JTM 20kV) while secondary distribution is low voltage network (JTR 220 / 380V). The distribution network is part of the power system closest to the customer or the load compared to the transmission network.At this time PT. PLN (Persero) experiencing power loss that occurs at the point of connection of low voltage on the use of pierching connector. This study is to analyze the calculation of loss of  power at low voltage network (JTR) by doing comparison of measurement between input with output at connection point of pierching connector with line tap connector. For  conditions required evaluation and analysis for replanning that takes into account the planning criteria such as voltage  drop and take into account the loss of power.


2018 ◽  
Vol 3 (1) ◽  
pp. 8
Author(s):  
Rishal Asri

Provinsi Lampung merupakan salah satu pulau terbesar di Indonesia. Energi merupakan salah satu faktor sebuah negara atau daerah dapat berkembang. Energi dapat berupa listrik, minyak, dan lain lain. Penyediaan energi di masa depan merupakan faktor kunci menentukan kebijakan umum pada pemerintah.Pada penelitian ini bertujuan untuk meningkatkan proyeksi penggunaan energi terbarukan sesuai dengan arah kebijakan energi nasional. Data yang digunakan adalah  produk domestic regional bruto, konsumsi listrik, konsumsi bahan bakar minyak, dan indikator energi lainnya. Pada penelitian ini meggunakan LEAP untuk memodelkan dan memprediksi kebutuhan energi pada tahun 2025.


Sign in / Sign up

Export Citation Format

Share Document