Changes in Water Transport across the Peritoneum during Treatment with Continuous Ambulatory Peritoneal Dialysis in Selected Patients with and without Peritonitis

2004 ◽  
Vol 24 (6) ◽  
pp. 571-579 ◽  
Author(s):  
Maria Radtke ◽  
Gry E. Albrektsen ◽  
Tor-Erik Widerøe ◽  
Tom I.L. Nilsen ◽  
Pål Romundstad ◽  
...  

Background The natural course of longitudinal changes in peritoneal permeability and membrane area has been studied mostly by performing single-dwell studies in selected patients during treatment with peritoneal dialysis. Purpose To evaluate the permeability characteristics of the peritoneal membrane by measuring drained ultrafiltration volume relative to initial glucose concentration in dialysis fluid from the start to the end of continuous ambulatory peritoneal dialysis (CAPD) treatment in a selected cohort of patients with and without peritonitis. Design A retrospective analysis of a group of patients whose peritoneal function was prospectively followed by recording drained ultrafiltration volume and glucose concentration in dialysis fluid for each dwell time, every day, during the time in CAPD treatment. Mean values from a 1-month period starting after the first 3 weeks of CAPD treatment were compared with the mean values from the last month of treatment. Approximately 11 500 exchanges were analyzed. Evaluations were done separately for short (day) and long (night) dwell times. Patients and Statistics Of 132 patients commencing CAPD treatment in the time period selected for inclusion, 51 had enough data to be included in this study. Of these, 29 patients experienced one or more episodes of successfully treated peritonitis. The selection of patients was not based upon patient characteristics, but upon criteria to satisfy predefined demands, such as number of measurements in each period, time since an episode of peritonitis, and time on CAPD treatment. Data were analyzed in three different groups: patients with episodes of peritonitis, patients without peritonitis, and both groups together. To assess changes between monthly mean at the start and at the end of CAPD, paired t-test was performed. Patients were also stratified into two groups according to low and high glucose in dialysis fluid at the start of CAPD (cutoff = 2 g/dL). Additionally, we used linear regression analyses to predict the level of drained ultrafiltration volume for a given level and change in glucose concentration. Mean treatment time for the entire group was 20 months (median 14.3 months), ranging from 6 to 69 months. Results No statistical differences in glucose concentrations were found between the periods compared. In the entire group there was an increase in ultrafiltration volume from the start to the end of CAPD treatment, for both day ( p = 0.009) and night ( p = 0.013) exchanges. Also, for patients without peritonitis, an increase appeared for day ( p = 0.046) and night exchanges ( p = 0.053). However, for the cohort with peritonitis, only an insignificant increase was indicated. Patient characteristics, diabetic patients, the need for glucose in dialysis fluid when commencing CAPD treatment, the number of episodes of peritonitis, and time on CAPD did not influence the change in ultrafiltration. Regression analyses showed higher ultrafiltration response to a given level and change in glucose concentration at the end of CAPD treatment compared to the start values, also for the cohort with peritonitis. The regression coefficient between these variables was also significantly changed for both day ( p < 0.0001) and night ( p = 0.027) exchanges. Conclusion A significant change in the regression coefficient between glucose in dialysis fluid and ultrafiltration volume reflects an increase in ultrafiltration response to a given level and change in glucose concentration during time on CAPD treatment. A parallel change after 5- and 9-hour dwells can be explained by a decrease in peritoneal surface area combined with a lesser decrease in peritoneal conductivity. However, changes in Starling forces across the peritoneal membrane are possible even in the absence of changes in peritoneal membrane characteristics.

1993 ◽  
Vol 84 (6) ◽  
pp. 619-626 ◽  
Author(s):  
E. Lamb ◽  
W. R. Cattell ◽  
A. Dawnay

1. Chronic use of hyperosmolar glucose solutions in continuous ambulatory peritoneal dialysis may cause glycation of peritoneal structural proteins which could contribute to membrane dysfunction and ultrafiltration failure. To determine whether glycation can occur in the environment of the dialysate, we have carried out studies using albumin as a model protein. 2. Glycated albumin was measured in the serum and dialysate of 46 patients on continuous ambulatory peritoneal dialysis (31 non-diabetic patients, 15 diabetic patients). Dialysate and serum glycated albumin (ranges 1.0-12.7% and 0.9-10.2%, respectively) were related to each other (r = 0.988, P <0.001), but dialysate glycated albumin was significantly higher than serum glycated albumin (P <0.0001), with the dialysate to serum glycated albumin ratio being greater than unity in 76% of patients (mean ratio 1.14). This implies either preferential transfer of glycated albumin across the peritoneal membrane or intraperitoneal glycation during the dwell period. 3. In vitro, significant glycation occurred in dialysate during a 6 h incubation period (P <0.01) at a rate related to the glucose concentration in the dialysate (rs = 0.63, P <0.05). The glycation rate was not significantly affected (P = 0.05) by factors other than the glucose concentration. 4. Our results demonstrate that protein glycation occurs within the peritoneum during continuous ambulatory peritoneal dialysis. Further studies are required to establish the relationship of glycation of structural proteins in the peritoneal membrane to membrane function.


2005 ◽  
Vol 25 (3_suppl) ◽  
pp. 135-136
Author(s):  
Cornelis H. Schröder

Since children on dialysis are treated most often with nightly intermittent peritoneal dialysis, adequacy of dialysis is determined by the number and duration of cycles, the volume of the dialysis fluid applied, and the choice of dialysis solution. The number and duration of cycles are dependent on the maximal acceptable duration of night rest and the permeability properties of the peritoneal membrane. The latter can be established by performance of a peritoneal equilibration test. The volume used should be about 1200 mL/m2 body surface area, and intraperitoneal pressure should be between 5 and 15 cm H2O. The dialysis solution administered should have a glucose concentration as low as possible, and an icodextrin daytime dwell may be considered.


Nephron ◽  
1986 ◽  
Vol 44 (3) ◽  
pp. 204-211 ◽  
Author(s):  
N. Di Paolo ◽  
G. De Sacchi ◽  
M. De Mia ◽  
E. Gaggiotti ◽  
L. Capotondo ◽  
...  

1993 ◽  
Vol 3 (8) ◽  
pp. 1508-1515
Author(s):  
T Liberek ◽  
N Topley ◽  
A Jörres ◽  
G A Coles ◽  
G M Gahl ◽  
...  

Solutions were formulated to examine, independently, the roles of osmolality and glucose in the reduction of viability and inhibition of phagocyte function by dextrose-containing peritoneal dialysis fluids. The exposure of neutrophils (polymorphonuclear leukocytes) to test fluids containing > or = 2.7% (wt/vol) glucose resulted in significant cytotoxicity as assessed by the release of lactate dehydrogenase above control values (7.12 +/- 2.65%). At the highest concentration of glucose (4.5%), lactate dehydrogenase release was 15.83 +/- 0.49% (P < 0.05). These effects were directly related to the presence of D-glucose in the test fluids. In contrast, phagocytosis and the release of leukotriene B4 from PMN stimulated with serum-treated zymosan were significantly inhibited in an osmolality-, but not glucose-, dependent manner. The inhibition of tumor necrosis factor alpha and interleukin-6 release from mononuclear leukocytes was inhibited by a combination of osmolality and monosaccharide concentration. Under the same conditions, PMN respiratory burst activation remained unaffected irrespective of glucose concentration or fluid osmolality. These data indicate that, in addition to the low pH of peritoneal dialysis fluid and its high lactate concentration, its glucose content (either directly or as a consequence of the resulting hyperosmolality of the fluid) inhibits cell functional parameters. These findings suggest clinically significant inhibition of host defense mechanisms because, in high-glucose dialysis fluids, osmolality does not reach physiologic values, even during extended intraperitoneal dwell periods.


Author(s):  
N. M. Zhilo ◽  
M. O. Mikhailov ◽  
E. L. Litinskaia ◽  
K. V. Pozhar

Introduction. The transition of glucose into the blood during automated peritoneal dialysis with regeneration of the dialysis fluid leads to a decreased removal of excess fluid from the body and corresponding violations of the water-salt balance.Aim. To consider a system for automatically maintaining the concentration of glucose in the dialysate solution, which provides effective ultrafiltration, as well as to propose a non-contact photometric feedback sensor.Materials and methods. The sensor is an optical system of an IR laser diode with a power of 30 mW and a wavelength of 1600 nm, a photodiode and a quartz tube, through which the test solution circulates. The sensor measures the attenuation of the radiation passing through the solution in a pulsed mode and calculates the glucose concentration. The selected combination of digital filters provides compensation for the noise of the optical system. Experimental studies of the efficiency of the sensor were carried out on peritoneal dialysis solutions with various concentrations of urea, creatinine, uric acid and glucose. At the beginning of the experiments, the sensor was calibrated in a pure solution.Results. It was shown that the developed sensor makes it possible to measure the concentration of glucose in a solution for peritoneal dialysis in the range of 42…220 mmol / l with a relative error of about 15%. The time of one measurement is about 1 minute, which makes it possible to obtain up-to-date information on the current concentration of the solution.Conclusion. This combination of characteristics will allow the sensor to be used in artificial kidney wearable devices for assessing the glucose content in the solution, calculating the time to change the solution and as a feedback sensor in a system for maintaining the concentration of the osmotic agent.


1990 ◽  
Vol 10 (2) ◽  
pp. 119-126 ◽  
Author(s):  
Claudio Ronco ◽  
Mariano Feriani ◽  
Stefano Chiaramonte ◽  
Alessandra Brendolan ◽  
Luisa Bragantini ◽  
...  

Pathophysiology of peritoneal ultrafiltration is analyzed in the present study. Peritoneal equilibration test is the easiest procedure to study in detail the possible causes of failure to control the ultrafiltration rate in patients undergoing peritoneal dialysis. Membrane failure, reduction in peritoneal blood flow, excessive lymphatic reabsorption catheter malposition, and fluid sequestration are the most common causes of ultrafiltration loss. Pharmacologic manipulation of peritoneal membrane, correction of mechanical inconvenients, reduction in peritonitis rate and in the level of immunostimulation of the mesotelial macrophages, together with a careful policy in terms of glucose concentration in the dialysate and dwell times may contribute not only to treat different forms of ultrafiltration loss but also to prevent their incidence.


1989 ◽  
Vol 9 (1) ◽  
pp. 75-78 ◽  
Author(s):  
Min Sun Park ◽  
Jean Lee ◽  
Moon Sung Lee ◽  
Seung Ho Baick ◽  
Seung Duk Hwang ◽  
...  

In order to evaluate peritoneal membrane function and responsiveness of peritoneal microcirculation to vasoactive agents in long-term continuous ambulatory peritoneal dialysis (CAPD) patients, we studied peritoneal clearances of urea (Curea) and creatinine (Ccr), protein concentrations in drained dialysate (D PC), peritoneal glucose absorption (% GA), and drained dialysate volume ( VD) before and after nitroprusside (NP) addition to dialysis solution in 17 long-term CAPD patients (mean duration of CAPD: 52 months) and the results were compared to those of 18 patients who were just trained for CAPD (mean duration: 0.6 month). There were no differences in the control (without NP) Curea, Ccr, D PC, %GA, and VD between the new and long-term CAPD patients. Curea, Ccr, and D PC increased significantly with NP in both new and long-term patients. Curea and Ccr with NP were not different between the new and long-term patients but D PC with NP was significantly lower in the long-term CAPD patients. The results of this study suggest that peritoneal solute clearances and the responsiveness of peritoneal microcirculation to NP remain unchanged after four years of CAPD, despite recurrent episodes of peritonitis.


2003 ◽  
Vol 23 (2_suppl) ◽  
pp. 26-30 ◽  
Author(s):  
Irini Savidaki ◽  
Dionisios Karavias ◽  
Florentia Sotsiou ◽  
Sotiria Alexandri ◽  
Pantelitsa Kalliakmani ◽  
...  

Background Long-term exposure of peritoneal membrane to bioincompatible dialysis solutions leads to structural changes and loss of ultrafiltration capability. Objective We studied the possible relationship between histologic change and the transport characteristics of peritoneal membrane and adequacy of dialysis in continuous ambulatory peritoneal dialysis (CAPD) patients. Patients and Methods The study included 18 CAPD patients (11 men, 7 women) who underwent a peritoneal biopsy either at initiation of treatment (group A, n = 9) or after a mean of 4 years on CAPD (group B, n = 9). The morphologic changes in the mesothelial cells and the vascular compartment and the thickness of the submesothelial collagenous zone were estimated and compared with observations from 6 patients with normal renal function who underwent biopsy of the parietal peritoneum during abdominal surgery. The relationship of the observed changes in CAPD patients to results from a peritoneal equilibration test (PET) and to adequacy of dialysis [total weekly creatinine clearance (CCr) and Kt/V urea] were also investigated. Results The main histologic changes in both groups of patients were loss of mesothelial cells and decrease in the normal mesothelial surface, thickening of the submesothelial collagenous zone, and presence of vascular hyalinosis. The thickness of the submesothelial collagenous zone in both groups of patients was significantly greater than that found in controls (410 μm and 580 μm vs 50 μm, p < 0.05). Although no significant difference was found between morphologic change in the peritoneal membrane of uremic patients starting on CAPD and those who had been on peritoneal dialysis (PD) for a mean period of 4 years, a trend was observed toward more severe lesions in the latter patients. The PET, CCr, and Kt/V urea were not significantly different in the two groups of patients. Those parameters also showed no significant changes when examined at initiation of CAPD and after a mean of 4 years of PD in the same patients (group B). No significant correlations were observed between the histologic changes and the PET, CCr, or Kt/V in both groups of patients. Conclusions Significant structural changes are observed in the peritoneal membrane of uremic patients, and those changes become worse with CAPD treatment. Structural changes are not followed by functional changes during the first 4 years on CAPD.


2008 ◽  
Vol 28 (3_suppl) ◽  
pp. 107-113
Author(s):  
Talerngsak Kanjanabuch ◽  
Monchai Siribamrungwong ◽  
Rungrote Khunprakant ◽  
Sirigul Kanjanabuch ◽  
Piyathida Jeungsmarn ◽  
...  

⋄ Background Continuous exposure of the peritoneal membrane to dialysis solutions during long-term dialysis results in mesothelial cell loss, peritoneal membrane damage, and thereby, ultrafiltration (UF) failure, a major determinant of mortality in patients on continuous ambulatory peritoneal dialysis (CAPD). Unfortunately, none of tests available today can predict long-term UF decline. Here, we propose a new tool to predict such a change. ⋄ Mesothelial cells from 8-hour overnight effluents (1.36% glucose dialysis solution) were harvested, co-stained with cytokeratin (a mesothelial marker) and TUNEL (an apoptotic marker), and were counted using flow cytometry in 48 patients recently started on CAPD. Adequacy of dialysis, UF, nutrition status, dialysate cancer antigen 125 (CA125), and a peritoneal equilibration test (3.86% glucose peritoneal dialysis solution) were simultaneously assessed and were reevaluated 1 year later. ⋄ Results The numbers of total and apoptotic mesothelial cells were 0.19 ± 0.19 million and 0.08 ± 0.12 million cells per bag, respectively. Both numbers correlated well with the levels of end dialysate–to–initial dialysate (D/D0) glucose, dialysate-to-plasma (D/P) creatinine, and sodium dipping. Notably, the counts of cells of both types in patients with diabetes or with high or high-average transport were significantly greater than the equivalent counts in nondiabetic patients or those with low or low-average transport. A cutoff of 0.06 million total mesothelial cells per bag had sensitivity of 1 and a specificity of 0.75 in predicting a further decline in D/D0 glucose and a sensitivity of 0.86 and a specificity of 0.63 to predict a further decline in UF over a 1-year period. In contrast, dialysate CA125 and other measured parameters had low predictive values. ⋄ Conclusions The greater the loss of exfoliated cells, the worse the expected decline in UF. The ability of a count of mesothelial cells to predict a future decline in UF warrants further investigation in clinical practice.