scholarly journals Seismic performance of a load-bearing prefabricated composite wall panel structure for residential construction

2020 ◽  
Vol 23 (13) ◽  
pp. 2928-2941
Author(s):  
Qunyi Huang ◽  
John Orr ◽  
Yanxia Huang ◽  
Feng Xiong ◽  
Hongyu Jia

To improve both seismic performance and thermal insulation of low-rise housing in rural areas of China, this study proposes a load-bearing prefabricated composite wall panel structure that achieves appropriate seismic performance and energy efficiency using field-assembled load-bearing prefabricated composite wall panels. A 1:2 scale prototype built using load-bearing prefabricated composite wall panel is subjected to quasi-static testing so as to obtain damage characteristics, load-bearing capacity and load–displacement curves in response to a simulated earthquake. As a result, seismic performance indicators of load-bearing capacity, deformation and energy-dissipating characteristics, are assessed against the corresponding seismic design requirements for rural building structures of China. Experimental results indicate that the earthquake-resistant capacity of the prototype is 68% higher than the design value. The sample has a ductility factor of 4.7, which meets the seismic performance requirement mandating that the ductility factor of such concrete structures should exceed 3. The design can be further optimized to save the consumption of material. This shows that the load-bearing prefabricated composite wall panel structure developed here has decent load-bearing capacity, ductility and energy dissipation abilities, a combination of which is in line with the seismic design code. A new construction process proposed here based on factory prefabrication and field assembly leads to a considerable reduction of energy consumption.

2018 ◽  
Vol 763 ◽  
pp. 235-242
Author(s):  
Iathong Chan ◽  
Yuji Koetaka

Steel moment frames are designed to ensure sufficient energy absorption capacity by achieving an entire beam-hinging collapse mechanism against severe earthquakes. Therefore, the column overdesign factor is stipulated in seismic design codes in some countries. For example in Japanese seismic design code, the specified column overdesign factor is 1.5 or more for steel moment frames with square tube columns. And this paper describes seismic response by 3D analysis of steel moment frames, and presents seismic demand for the column overdesign factor to keep the damage of square tube columns below the specified limit of plastic deformation. The major parameters are column overdesign factor, horizontal load bearing capacity, shape of frames and input direction of ground motion. In order to investigate 3D behavior of frames and correlation between plastic deformation of columns and column over design factor, apparent column overdesign factor, which is defined as the ratio of full plastic moment of the column (s) to the full plastic moment of the beam (s) projected in the input direction of the ground motion, is introduced. From the earthquake response analysis, it is clarified that the profile of maximum value of cumulative plastic deformation of columns to apparent column overdesign factor, with the similar horizontal load bearing capacity, are nearly identical regardless of number of stories, floor plan, and input direction of ground motion. As a result, the required column overdesign factor to keep the damage of columns below the limit of plastic deformation is proposed under the reliability index of 2.


2015 ◽  
Vol 660 ◽  
pp. 208-212 ◽  
Author(s):  
Mihai Fofiu ◽  
Andrei Bindean ◽  
Valeriu Stoian

This paper presents the retrofitting procedure used on a precast reinforced concrete wall panel (PRCWP) in order to restore its initial load bearing capacity. The specimen used in this experimental test is one from the residential multistoried buildings constructed in Romania from the 1970 onwards. All of the characteristics of the element are from the specific era, only scaled down with a factor of 1:1,2. The element was subjected to in-plane reversed cyclic loading to simulate its seismic behavior and obtain its maximum load bearing capacity. After the test we retrofitted the element using Carbon Fiber Strips Externally Bonded (EBR) and anchored with Carbon Fiber Reinforced Polymers (CFRP) mesh. The porpoise of the paper is to compare the maximum loading bearing capacity of the unstrengthen and strengthen elements in order to compare them and examine the efficiency of this retrofitting procedure.


2014 ◽  
Vol 1049-1050 ◽  
pp. 246-250
Author(s):  
Li Cheng Pan ◽  
Xi Yan Wang ◽  
Deng Feng Wang

In wall-column structural system of electrostatic precipitator casing, wall will share the load with column and provide lateral bracing support when the load is applied on the column .Then the wall panel exert the stressed skin effect, which will influence its load bearing capacity. By nonlinear finite element method, when wall panel exerts stressed skin effect, whether the effect will influence the wall bearing capacity is investigated as well as the failure mode. The relationship is analyzed between the loading level onto column, panel thickness, loading form onto wall and the affecting degree on the bearing capacity of wall panel. The computation results indicate that the bearing capacity of wall panel is lower when it exerts the stressed skin effect. When the wall is thin, the weakening degree of panel bearing capacity resulting from stressed skin effect is slightly affected by loading level onto column. When the wall is thicker, the weakening degree of panel bearing capacity increases apparently as the loading level onto column increases. For a certain loading level onto column, compared with the locally loaded wall panel, the impact on load bearing capacity is greater for the globally loaded wall panel. Research work has reference value for the calculation and design of enclosure structures of electrostatic precipitator casing.


2020 ◽  
Vol 62 (1) ◽  
pp. 55-60
Author(s):  
Per Heyser ◽  
Vadim Sartisson ◽  
Gerson Meschut ◽  
Marcel Droß ◽  
Klaus Dröder

2017 ◽  
Vol 68 (1) ◽  
pp. 94-100
Author(s):  
Oana Tanculescu ◽  
Adrian Doloca ◽  
Raluca Maria Vieriu ◽  
Florentina Mocanu ◽  
Gabriela Ifteni ◽  
...  

The load-bearing capacity and fracture pattern of direct inlay-retained FRC FDPs with two different cross-sectional designs of the ponticwere tested. The aim of the study was to evaluate a new fibre disposition. Two types of composites, Filtek Bulk Fill Posterior Restorative and Filtek Z250 (3M/ESPE, St. Paul, MN, USA), and one braided polyethylene fibre, Construct (Kerr, USA) were used. The results of the study suggested that the new tested disposition of the fibres prevented in some extend the delamination of the composite on buccal and facial sides of the pontic and increased the load-bearing capacity of the bridges.


2021 ◽  
Vol 11 (6) ◽  
pp. 2652
Author(s):  
Jung Han Kim ◽  
Ick-Hyun Kim ◽  
Jin Ho Lee

When a seismic force acts on bridges, the pier can be damaged by the horizontal inertia force of the superstructure. To prevent this failure, criteria for seismic reinforcement details have been developed in many design codes. However, in moderate seismicity regions, many existing bridges were constructed without considering seismic detail because the detailed seismic design code was only applied recently. These existing structures should be retrofitted by evaluating their seismic performance. Even if the seismic design criteria are not applied, it cannot be concluded that the structure does not have adequate seismic performance. In particular, the performance of a lap-spliced reinforcement bar at a construction joint applied by past practices cannot be easily evaluated analytically. Therefore, experimental tests on the bridge piers considering a non-seismic detail of existing structures need to be performed to evaluate the seismic performance. For this reason, six small scale specimens according to existing bridge piers were constructed and seismic performances were evaluated experimentally. The three types of reinforcement detail were adjusted, including a lap-splice for construction joints. Quasi-static loading tests were performed for three types of scale model with two-column piers in both the longitudinal and transverse directions. From the test results, the effect on the failure mechanism of the lap-splice and transverse reinforcement ratio were investigated. The difference in failure characteristics according to the loading direction was investigated by the location of plastic hinges. Finally, the seismic capacity related to the displacement ductility factor and the absorbed energy by hysteresis behavior for each test were obtained and discussed.


2021 ◽  
Vol 60 (1) ◽  
pp. 503-518
Author(s):  
Juan Han ◽  
Lu Zhu ◽  
Hai Fang ◽  
Jian Wang ◽  
Peng Wu

Abstract This article proposed an innovative composite sandwich structure reinforced with trapezoidal latticed webs with angles of 45°, 60° and 75°. Four specimens were conducted according to quasi-static compression methods to investigate the compressive behavior of the novel composite structures. The experimental results indicated that the specimen with 45° trapezoidal latticed webs showed the most excellent energy absorption ability, which was about 2.5 times of the structures with vertical latticed webs. Compared to the traditional composite sandwich structure, the elastic displacement and ultimate load-bearing capacity of the specimen with 45° trapezoidal latticed webs were increased by 624.1 and 439.8%, respectively. Numerical analysis of the composite sandwich structures was carried out by using a nonlinear explicit finite element (FE) software ANSYS/LS-DYNA. The influence of the thickness of face sheets, lattice webs and foam density on the elastic ultimate load-bearing capacity, the elastic displacement and initial stiffness was analyzed. This innovative composite bumper device for bridge pier protection against ship collision was simulated to verify its performance. The results showed that the peak impact force of the composite anti-collision device with 45° trapezoidal latticed webs would be reduced by 17.3%, and the time duration will be prolonged by about 31.1%.


Sign in / Sign up

Export Citation Format

Share Document